Two-dimensional electro-optical multiphoton microscopy

被引:0
|
作者
Farinella, Deano M. [1 ]
Stanek, Samuel [2 ]
Jayakumar, Harishankar [1 ]
Newman, Zachary L. [1 ]
Gable, Jacob [1 ]
Leger, James [2 ]
Kerlin, Aaron [1 ]
机构
[1] Univ Minnesota, Dept Neurosci, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN USA
基金
美国国家卫生研究院;
关键词
multiphoton microscopy; electro-optical deflector; in vivo imaging; voltage imaging; BEAM DEFLECTION; STED NANOSCOPY; ULTRAFAST; INDICATOR;
D O I
10.1117/1.NPh.11.2.025005
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Significance: The development of genetically encoded fluorescent indicators of neural activity with millisecond dynamics has generated demand for ever faster two-photon (2P) imaging systems, but acoustic and mechanical beam scanning technologies are approaching fundamental limits. We demonstrate that potassium tantalate niobate (KTN) electro-optical deflectors (EODs), which are not subject to the same fundamental limits, are capable of ultrafast two-dimensional (2D) 2P imaging in vivo. Aim: To determine if KTN-EODs are suitable for 2P imaging, compatible with 2D scanning, and capable of ultrafast in vivo imaging of genetically encoded indicators with millisecond dynamics. Approach: The performance of a commercially available KTN-EOD was characterized across a range of drive frequencies and laser parameters relevant to in vivo 2P microscopy. A second KTN-EOD was incorporated into a dual-axis scan module, and the system was validated by imaging signals in vivo from ASAP3, a genetically encoded voltage indicator. Results: Optimal KTN-EOD deflection of laser light with a central wavelength of 960 nm was obtained up to the highest average powers and pulse intensities tested (power: 350 mW; pulse duration: 118 fs). Up to 32 resolvable spots per line at a 560 kHz line scan rate could be obtained with single-axis deflection. The complete dual-axis EO 2P microscope was capable of imaging a 13 mu m by 13 mu m field-of-view at over 10 kHz frame rate with similar to 0.5 mu m lateral resolution. We demonstrate in vivo imaging of neurons expressing ASAP3 with high temporal resolution. Conclusions: We demonstrate the suitability of KTN-EODs for ultrafast 2P cellular imaging in vivo, providing a foundation for future high-performance microscopes to incorporate emerging advances in KTN-based scanning technology.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Advanced electro-optical transmitters
    Belmonte, M
    Balsamo, S
    Pensa, S
    Pircalaboiu, D
    Pruneri, V
    Photonic Materials, Devices, and Applications, Pts 1 and 2, 2005, 5840 : 614 - 626
  • [42] Electro-optical silicon isolator
    Lira, Hugo L. R.
    Yu, Zongfu
    Fan, Shanhui
    Lipson, Michal
    2012 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2012,
  • [43] ELECTRO-OPTICAL CURVE RANGING
    ESSON, DMR
    ENGINEERING MATERIALS AND DESIGN, 1971, 14 (02): : 105 - &
  • [44] ANOTHER ELECTRO-OPTICAL EFFECT
    不详
    MESURES REGULATION AUTOMATISME, 1969, 34 (1-2): : 120 - &
  • [45] IMPROVED ELECTRO-OPTICAL RECTIFIER
    RILEY, DH
    PHOTOGRAMMETRIC ENGINEERING AND REMOTE SENSING, 1979, 45 (06): : 781 - 781
  • [46] ELECTRO-OPTICAL MEASUREMENT OF AEROSOLS
    STRAUBEL, H
    TECHNISCHES MESSEN, 1981, 48 (06): : 199 - 210
  • [47] Electro-optical field mapping
    Mueller, H
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1941, 31 (04) : 286 - 291
  • [48] ELECTRO-OPTICAL AND INFRARED DEVICES
    HORNE, DF
    PHYSICS IN TECHNOLOGY, 1982, 13 (05): : 223 - 224
  • [49] Electro-optical sensors overview
    Crawford, FJ
    IEEE AEROSPACE AND ELECTRONIC SYSTEMS MAGAZINE, 1998, 13 (10) : 17 - 24
  • [50] Electro-optical voltage transformer
    Xu, Y
    Ye, MY
    Cui, Y
    FIBER OPTIC AND LASER SENSORS AND APPLICATIONS: INCLUDING DISTRIBUTED AND MULTIPLEXED FIBER OPTIC SENSORS VII, 1999, 3541 : 224 - 230