Neurovascular Imaging with Ultra-High-Resolution Photon-Counting CT: Preliminary Findings on Image-Quality Evaluation

被引:4
|
作者
Toth, Adrienn [1 ]
Chetta, Justin A. [1 ]
Yazdani, Milad [1 ]
Matheus, M. Gisele [1 ]
O'Doherty, Jim [1 ,2 ]
Tipnis, Sameer V. [1 ]
Spampinato, M. Vittoria [1 ]
机构
[1] Med Univ South Carolina, Dept Radiol & Radiol Sci, 209D Clin Sci Bldg,96 Jonathan Lucas St, Charleston, SC 29425 USA
[2] Siemens Med Solut, Malvern, PA USA
关键词
DETECTOR CT; INTRACRANIAL ANEURYSMS; ANGIOGRAPHY; DIAGNOSIS; VOLUME;
D O I
10.3174/ajnr.A8350
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The first-generation photon-counting detector (PCD) CT was recently introduced into clinical practice and represents a promising innovation in high-resolution CT imaging. The purpose of this study was to assess the image quality of ultra-high-resolution (UHR) PCD-CT compared with energy-integrating detector (EID)-CT, and to explore different reconstruction kernel sharpness levels for the evaluation of intracranial aneurysms. MATERIALS AND METHODS: Ten patients with intracranial saccular aneurysms, who had previously undergone conventional EID-CT, were prospectively enrolled. CT angiograms were acquired on a clinical dual-source PCD-CT in UHR mode, and reconstructed with four vascular kernels (Bv36, Bv40, Bv44, Bv48). Quantitative and qualitative image quality parameters of the intracranial arteries were evaluated. For the quantitative analysis (image noise, SNR, CNR), regions of interest were manually placed at standard anatomical intracranial and extracranial locations by one author. In addition, vessel border sharpness was evaluated quantitatively. For the qualitative analysis, three blinded neuroradiologists rated PCD-CT and EID-CT image quality for the evaluation of the intracranial vessels (i.e., the aneurysms and nine standard vascular branching locations) on a 5-point Likert-type scale. Additionally, readers independently selected their preferred kernel among the four kernels evaluated on PCD-CT. RESULTS: In terms of quantitative image quality, Bv48, the sharpest kernel, yielded increased image noise, and decreased SNR and CNR parameters compared to Bv36, the smoothest kernel. Compared to EID-CT, the Bv48 kernel offered better quantitative image quality for the evaluation of small intracranial vessels (p < .001). Image quality ratings of the Bv48 were superior to those of the EIDCT, and not significantly different from ratings of the B44 reconstruction kernel. When comparing side-by-side all four PCD-CT reconstruction kernels, readers selected the B48 kernel as the best to visualize the aneurysms in 80% of cases. CONCLUSIONS: UHR PCD-CT provides improved image quality for neurovascular imaging. Although the less sharp kernels provided superior SNR and CNR, the sharpest kernels delivered the best subjective image quality on PCD-CT for the evaluation of intracranial aneurysms.
引用
收藏
页码:1450 / 1457
页数:8
相关论文
共 50 条
  • [21] Ultra-High-Resolution Temporal Bone Anatomy Using Photon-counting CT: Added Value of Improved Spatial Resolution
    Ansari, Shehbaz
    Jhaveri, Miral D.
    Suthar, Pokhraj Prakashchandra
    DeSanto, Jeffrey
    Gaddikeri, Santhosh
    Vattoth, Surjith
    RADIOGRAPHICS, 2024, 44 (10)
  • [22] Optimization of the Reconstruction Settings for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lungs
    Graafen, Dirk
    Halfmann, Moritz C.
    Emrich, Tilman
    Yang, Yang
    Kreuter, Michael
    Dueber, Christoph
    Kloeckner, Roman
    Mueller, Lukas
    Jorg, Tobias
    DIAGNOSTICS, 2023, 13 (23)
  • [23] Potential of ultra-high-resolution photon-counting CT of bone metastases: initial experiences in breast cancer patients
    E. Wehrse
    S. Sawall
    L. Klein
    P. Glemser
    S. Delorme
    H.-P. Schlemmer
    M. Kachelrieß
    M. Uhrig
    C. H. Ziener
    L. T. Rotkopf
    npj Breast Cancer, 7
  • [24] Potential of ultra-high-resolution photon-counting CT of bone metastases: initial experiences in breast cancer patients
    Wehrse, E.
    Sawall, S.
    Klein, L.
    Glemser, P.
    Delorme, S.
    Schlemmer, H. -P.
    Kachelriess, M.
    Uhrig, M.
    Ziener, C. H.
    Rotkopf, L. T.
    NPJ BREAST CANCER, 2021, 7 (01)
  • [25] Quantum Iterative Reconstruction for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lung
    Sartoretti, Thomas
    Racine, Damien
    Mergen, Victor
    Jungblut, Lisa
    Monnin, Pascal
    Flohr, Thomas G.
    Martini, Katharina
    Frauenfelder, Thomas
    Alkadhi, Hatem
    Euler, Andre
    DIAGNOSTICS, 2022, 12 (02)
  • [26] Potential of employing a quantum iterative reconstruction algorithm for ultra-high-resolution photon-counting detector CT of the hip
    Huflage, H.
    Grunz, J. -P
    Kunz, A. S.
    Patzer, T. S.
    Sauer, S. T.
    Christner, S. A.
    Petritsch, B.
    Erguen, S.
    Bley, T. A.
    Luetkens, K. S.
    RADIOGRAPHY, 2023, 29 (01) : 44 - 49
  • [27] Evaluation of Coronary Plaques and Stents with Conventional and Photon-counting CT: Benefits of High-Resolution Photon-counting CT
    Rajagopal, Jayasai R.
    Farhadi, Faraz
    Richards, Taylor
    Nikpanah, Moozhan
    Sahbaee, Pooyan
    Shanbhag, Sujata M.
    Bandettini, W. Patricia
    Saboury, Babak
    Malayeri, Ashkan A.
    Pritchard, William F.
    Jones, Elizabeth C.
    Samei, Ehsan
    Chen, Marcus Y.
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2021, 3 (05):
  • [28] Ultra-High-Resolution Photon-Counting Detector CT Benefits Visualization of Abdominal Arteries: A Comparison to Standard-Reconstruction
    Zhang, Huan
    Xing, Yue
    Wang, Lingyun
    Hu, Yangfan
    Xu, Zhihan
    Chen, Haoda
    Lu, Junjie
    Yang, Jiarui
    Ding, Bei
    Hu, Weiguo
    Zhong, Jingyu
    JOURNAL OF IMAGING INFORMATICS IN MEDICINE, 2024,
  • [29] Ultra-high-resolution photon-counting detector CT in evaluating coronary stent patency: a comparison to invasive coronary angiography
    Hagar, Muhammad Taha
    Soschynski, Martin
    Saffar, Ruben
    Molina-Fuentes, Moises Felipe
    Weiss, Jakob
    Rau, Alexander
    Schuppert, Christopher
    Ruile, Philipp
    Faby, Sebastian
    Schibilsky, David
    von zur Muehlen, Constantin
    Schlett, Christopher L.
    Bamberg, Fabian
    Krauss, Tobias
    EUROPEAN RADIOLOGY, 2024, 34 (07) : 4273 - 4283
  • [30] A Blooming correction technique for improved vasa vasorum detection using an ultra-high-resolution photon-counting detector CT
    Marsh, Jeffrey, Jr.
    Rajendran, Kishore
    Tao, Shengzhen
    Vercnocke, Andrew
    Anderson, Jill
    Leng, Shuai
    Ritman, Erik
    McCollough, Cynthia
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312