The diagnostic value of MRI-based vertebral bone quality score for osteoporosis or osteopenia in patients undergoing lumbar surgery: a meta-analysis

被引:1
|
作者
Hu, Fangke [1 ]
Li, Xiaopeng [2 ,3 ]
Zhao, Dong [1 ]
Chen, Chao [1 ]
Liu, Gang [1 ]
Yang, Qiang [1 ]
机构
[1] Tianjin Univ, Tianjin Hosp, Dept Spine Surg, Tianjin, Peoples R China
[2] Weifang Peoples Hosp, Dept Spine Surg, Weifang, Shandong, Peoples R China
[3] Tianjin Med Univ, Clin Coll Orthoped, Tianjin, Peoples R China
关键词
Dual-energy X-ray absorptiometry; Magnetic resonance imaging; Osteopenia; Osteoporosis; Quantitative computed tomography; Vertebral bone quality score; MARROW FAT-CONTENT; FRACTURES; DENSITY; TOOL;
D O I
10.1007/s00198-024-07190-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The importance of osteoporosis assessment before lumbar surgery is well recognized. The MRI-based Vertebral Bone Quality (VBQ) score is introduced to evaluate bone quality; however, its diagnostic value has not been well documented. The purpose of this meta-analysis was to summarize the diagnostic value of the VBQ score for osteoporosis or osteopenia in patients undergoing lumbar surgery. We comprehensively searched electronic databases for studies exploring the diagnostic accuracy of the VBQ score for osteoporosis/osteopenia in patients with lumbar disease following the PRISMA guidelines. The quality of the included studies was assessed. The VBQ scores were compared between the groups, and the pooled sensitivity, specificity, and summary receiver operating characteristic (ROC) were calculated. Publication bias was assessed, and meta-regression was conducted. We included 17 studies with a total of 2815 patients, with a mean age of 66.4 years and a percentage of females of 72.5%. According to the QUADAS-2 tool, the quality of the included studies was relatively high. The results showed a significantly higher VBQ score in the osteoporosis/osteopenia group compared with the control group. According to the mean VBQ cutoff value of 3.02 +/- 0.38 for the diagnosis of osteoporosis, the pooled sensitivity and specificity were 0.76 and 0.74, respectively, and the AUC was 0.81. According to the mean VBQ cutoff value of 2.31 +/- 0.18 for the diagnosis of osteopenia, the pooled sensitivity and specificity were 0.78 and 0.58, respectively, and the AUC was 0.76. The MRI-based VBQ score could provide useful information for identifying patients with low bone mass who need further evaluation. Future prospective studies are still needed to evaluate the complementary role of the VBQ score.
引用
收藏
页码:1881 / 1895
页数:15
相关论文
共 50 条
  • [41] Comparison of the predictive values of MRI-based vertebral bone quality scores for the determination of osteoporosis in different diseases
    Wang, Lu
    Deng, Qian
    Wang, Bang
    Li, Xing-Bin
    Sha, Zhi-Jun
    Wang, Zhao-Rui
    Huang, Ai-Bing
    EUROPEAN SPINE JOURNAL, 2024, 33 (04) : 1504 - 1510
  • [42] A novel MRI-based score assessing trabecular bone quality to predict vertebral compression fractures in patients with spinal metastasis
    Ehresman, Jeff
    Schilling, Andrew
    Pennington, Zach
    Gui, Chengcheng
    Chen, Xuguang
    Lubelski, Daniel
    Ahmed, A. Karim
    Cottrill, Ethan
    Khan, Majid
    Redmond, Kristin J.
    Sciubba, Daniel M.
    JOURNAL OF NEUROSURGERY-SPINE, 2020, 32 (04) : 499 - 506
  • [43] Assessing the utility of MRI-based vertebral bone quality (VBQ) for predicting lumbar pedicle screw loosening
    Yu Gao
    Wu Ye
    Xuhui Ge
    Haofan Wang
    Junjun Xiong
    Yufeng Zhu
    Zhuanghui Wang
    Jiaxing Wang
    Pengyu Tang
    Wei Liu
    Weihua Cai
    European Spine Journal, 2024, 33 : 289 - 297
  • [44] Assessing the utility of MRI-based vertebral bone quality (VBQ) for predicting lumbar pedicle screw loosening
    Gao, Yu
    Ye, Wu
    Ge, Xuhui
    Wang, Haofan
    Xiong, Junjun
    Zhu, Yufeng
    Wang, Zhuanghui
    Wang, Jiaxing
    Tang, Pengyu
    Liu, Wei
    Cai, Weihua
    EUROPEAN SPINE JOURNAL, 2024, 33 (01) : 289 - 297
  • [45] Improving Osteoporosis Prediction Using Vertebral Bone Quality Score and Paravertebral Muscle Measurements From Lumbar MRI Scans
    Ozmen, Emre
    Bicer, Ozancan
    Baris, Alican
    Circi, Esra
    Yuksel, Serdar
    Beytemur, Ozan
    Kesiktas, Fatma Nur
    CLINICAL SPINE SURGERY, 2024, 37 (08): : 357 - 363
  • [46] Vertebral bone quality score as a new tool for osteoporosis diagnosis in patients undergoing lumbosacral fusion surgery: a single center cohort study
    Najafi, Arvin
    Bagheri, Ali Baradaran
    Hadavi, Dorsa
    Mobedi, Aidin
    Azarsina, Salman
    Chaghamirzayi, Pouria
    EUROPEAN JOURNAL OF TRANSLATIONAL MYOLOGY, 2024, 34 (01)
  • [47] Sex differences in the accuracy of vertebral bone quality score assessing bone density in patients undergoing lumbar spinal fusion
    Wang, Yunsheng
    Wang, Feng
    Tong, Tong
    Miao, Dechao
    Li, Wenshuai
    Zhu, Houze
    Zheng, Xiao
    Wang, Linfeng
    JOURNAL OF NEUROSURGERY-SPINE, 2024, 40 (04) : 405 - 411
  • [48] Novel MRI-Based Pedicle Bone Quality Score Independently Predicts Pedicle Screw Loosening after Degenerative Lumbar Fusion Surgery
    Li, Qiujiang
    Fu, Haiying
    Yang, Huiliang
    Yang, Xi
    Wang, Lei
    Song, Yueming
    ORTHOPAEDIC SURGERY, 2024, 16 (10) : 2372 - 2379
  • [49] The Current Diagnostic Performance of MRI-Based Radiomics for Glioma Grading: A Meta-Analysis
    De Maria, Lucio
    Ponzio, Francesco
    Cho, Hwan-ho
    Skogen, Karoline
    Tsougos, Ioannis
    Gasparini, Mauro
    Zeppieri, Marco
    Ius, Tamara
    Ugga, Lorenzo
    Panciani, Pier Paolo
    Fontanella, Marco Maria
    Brinjikji, Waleed
    Agosti, Edoardo
    JOURNAL OF INTEGRATIVE NEUROSCIENCE, 2024, 23 (05)
  • [50] Predictive value of different site-specific MRI-based assessments of bone quality for cage subsidence among patients undergoing oblique lumbar interbody fusion
    Zheng, Xiao
    Tong, Tong
    Li, Wenshuai
    Chen, Junyi
    Zhu, Houze
    Wang, Yunsheng
    Wang, Linfeng
    JOURNAL OF NEUROSURGERY-SPINE, 2023, 41 (02) : 246 - 253