2D and 3D microstructural analysis of the iliotibial tract

被引:1
|
作者
Manon, Julie [1 ,2 ,3 ]
Gallant, Laurie [4 ]
Gerard, Paul [4 ]
Fieve, Lies [4 ]
Schneidewind, Pierre [4 ,5 ]
Pyka, Grzegorz [5 ,6 ]
Kerckhofs, Greet [5 ,6 ]
Lengele, Benoit [4 ,7 ]
Cornu, Olivier [1 ,2 ,3 ]
Behets, Catherine [4 ]
机构
[1] Univ Catholique Louvain UCLouvain, Inst Rech Expt & Clin IREC, Neuromusculoskeletal Lab NMSK, Brussels, Belgium
[2] Clin Univ St Luc, Dept Orthopaed & Trauma Surg, Brussels, Belgium
[3] Clin Univ St Luc, Dept Cell & Tissue Therapy, Brussels, Belgium
[4] UCLouvain IREC, Morphol Lab MORF, Brussels, Belgium
[5] UCLouvain IREC, ContrasTTeam, Brussels, Belgium
[6] UCLouvain, Inst Mech Mat & Civil Engn IMMC, Mechatron Elect Energy & Dynam Syst MEED, Louvain La Neuve, Belgium
[7] Clin Univ St Luc, Dept Plast & Reconstruct Surg, Brussels, Belgium
关键词
2D & 3D histology; fascia lata; fibre orientation; iliotibial band; iliotibial tract; spatial tissue organisation; BAND THICKNESS; FASCIA; ANATOMY;
D O I
10.1111/joa.14125
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
The fascial system has gained recognition for its integral role in connecting skin, superficial and deep fasciae, and underlying muscles. However, consensus on its microstructure depending on its topography remains elusive as well as its implications in clinical practices, such as reconstructive surgery and physiotherapy techniques. This study focuses on the iliotibial tract (ITT) implicated in the iliotibial band syndrome. The goal is to describe microstructural characteristics using classical 2D histology and cryogenic contrast-enhanced microcomputed tomography (cryo-CECT) such as the total thickness, number of layers, layer thickness, fibre orientation and tortuosity, according to the specific topography. The total thickness of the ITT varied across topographic regions, with the superior part being on average thicker but non-significantly different from the other regions. The inferior part showed heterogeneity, with the anterior region (AI) being the thinnest and the posterior one (PI) the thickest. The ITT exhibited 1-3 layers, with no significant differences among regions. Most commonly, it consisted of two layers, except for the antero-superior (AS) and antero-middle (AM) regions, which sometimes had only one layer. The posterior regions frequently had 2 or 3 layers, with the PI region having the highest mean (2.7 layers). The intermediate layer was the thickest one, varying from the AI region (0.368 mm +/- 0.114) to the PI region (0.640 mm +/- 0.305). The superficial layer showed regional variability, with the AS region being the thinnest. The deep layer appeared thinner than the superficial one. Fibre orientation analysis indicated that the intermediate layer mainly consisted of oblique longitudinal fibres, orientated downward and forward, while the superficial and deep layers had transversal or oblique transversal fibres. Cryo-CECT 3D observations confirmed these findings, revealing distinct orientations for different layers. Fibre tortuosity exhibited differences based on orientation. Transversal fibres (>65 degrees) were significantly less tortuous than longitudinal fibres (<25 degrees) and oblique intermediate fibres (25 degrees-65 degrees), aligning with 3D plot observations. This quantitative study highlights various microstructural characteristics of the ITT, offering insights into its regional variations. The analysis accuracy is increased due to the novel technology of cryo-CECT which emerges as a valuable tool for precise assessment of 3D fibre orientation and tortuosity. These findings contribute to a deeper understanding of the ITT structure, useful in clinical practices, such as reconstructive surgery and physiotherapy, and future research endeavours.
引用
收藏
页码:725 / 739
页数:15
相关论文
共 50 条
  • [21] Comparison and analysis of 2D and 3D slope stability analysis results
    Lu Kun-lin
    Zhu Da-yong
    Yang Yang
    ROCK AND SOIL MECHANICS, 2012, 33 : 150 - +
  • [22] 2D vs 3D tracking in bacterial motility analysis
    Acres, Jacqueline
    Nadeau, Jay
    AIMS BIOPHYSICS, 2021, 8 (04): : 385 - 399
  • [23] Comparative analysis of 2D and 3D model of a PEMFC in COMSOL
    Lakshmi, R. Bakiya
    Harikrishnan, N. P.
    Juliet, A. Vimala
    APPLIED SURFACE SCIENCE, 2017, 418 : 99 - 102
  • [24] Experimental and computational analysis of 3D printed 2D lattices
    Mussini, Andrea
    Carter, Luke
    Villapun, Victor
    Cao, Emily
    Cox, Sophie
    Ginestra, Paola
    MATERIAL FORMING, ESAFORM 2024, 2024, 41 : 390 - 397
  • [25] Cognitive computing in analysis of 2D/3D medical images
    Ogiela, Lidia
    Tadeusiewicz, Ryszard
    Ogiela, Marek R.
    2007 INTERNATIONAL CONFERENCE ON INTELLIGENT PERVASIVE COMPUTING, PROCEEDINGS, 2007, : 15 - +
  • [26] 2D versus 3D in the kinematic analysis of the horse at the trot
    F. Miró
    R. Santos
    J. L. Garrido-Castro
    A. M. Galisteo
    R. Medina-Carnicer
    Veterinary Research Communications, 2009, 33 : 507 - 513
  • [27] Automated cell analysis in 2D and 3D: A comparative study
    Meyer, Michael G.
    Fauver, Mark
    Rahn, J. Richard
    Neumann, Thomas
    Patten, Florence W.
    Seibel, Eric J.
    Nelson, Alan C.
    PATTERN RECOGNITION, 2009, 42 (01) : 141 - 146
  • [28] 2D and 3D analysis methods of facial asymmetry in comparison
    Berssenbruegge, Philipp
    Berlin, Nina Franka
    Kebeck, Guenther
    Runte, Christoph
    Jung, Susanne
    Kleinheinz, Johannes
    Dirksen, Dieter
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (06) : E327 - E334
  • [29] Fast 2D to 3D Conversion Based on Wavelet Analysis
    Chiang, Te-Wei
    Tsai, Tienwei
    Lin, Yu-Hong
    Hsiao, Mann-Jung
    IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN AND CYBERNETICS (SMC 2010), 2010, : 3444 - 3448
  • [30] Numerical analysis of sedimentation of a 2D or 3D cold particle
    Maunoury, Aurelie
    Le Bot, Cedric
    Arquis, Eric
    MECHANICS RESEARCH COMMUNICATIONS, 2010, 37 (05) : 500 - 503