Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

被引:1
|
作者
Giacomini, Gabriele [1 ]
Chen, Wei [1 ]
D'Amen, Gabriele [2 ]
Rossi, Enrico [1 ]
Tricoli, Alessandro [2 ]
机构
[1] Brookhaven Natl Lab, Instrumentat Dept, Upton, NY 11973 USA
[2] Brookhaven Natl Lab, Phys Dept, Upton, NY 11973 USA
关键词
Low-Gain Avalanche Diodes; LGAD; Avalanche Diodes; APD; Avalanche noise; Gain; Charge-sensitive amplifier; TECHNOLOGY;
D O I
10.1016/j.nima.2024.169605
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. The signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Trench-Isolated Low Gain Avalanche Diodes (TI-LGADs)
    Paternoster, G.
    Borghi, G.
    Boscardin, M.
    Cartiglia, N.
    Ferrero, M.
    Ficorella, F.
    Siviero, F.
    Gola, A.
    Bellutti, P.
    IEEE ELECTRON DEVICE LETTERS, 2020, 41 (06) : 884 - 887
  • [32] Effect of inelastic ion collisions on low-gain avalanche detectors explained by an ASi-Sii-defect mode
    Lauer, Kevin
    Reiss, Stephanie
    Flototto, Aaron
    Peh, Katharina
    Bratek, Dominik
    Mueller, Robin
    Schulze, Dirk
    Beenken, Wichard
    Hiller, Erik
    Ortlepp, Thomas
    Krischok, Stefan
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2024, 555
  • [33] A simulation model of front-end electronics for high-precision timing measurements with low-gain avalanche detectors
    Pena, C.
    Deptuch, G.
    Xie, S.
    Apresyan, A.
    Narvaez, L.
    Ristori, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 940 : 119 - 124
  • [34] Characterization of Low Gain Avalanche Detector Prototypes' Response to Gamma Radiation
    Hoeferkamp, Martin
    Howard, Alissa
    Kramberger, Gregor
    Seidel, Sally
    Sorenson, Josef
    Yanez, Adam
    FRONTIERS IN PHYSICS, 2022, 10
  • [35] Radiation effects in Low Gain Avalanche Detectors after hadron irradiations
    Kramberger, G.
    Baselga, M.
    Cindro, V.
    Fernandez-Martinez, P.
    Flores, D.
    Galloway, Z.
    Gorisek, A.
    Greco, V.
    Hidalgo, S.
    Fadeyev, V.
    Mandic, I.
    Mikuz, M.
    Quirion, D.
    Pellegrini, G.
    Sadrozinski, H. F-W.
    Studen, A.
    Zavrtanik, M.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [36] Timing performance of thin Low Gain Avalanche Detectors (LGADs)
    Strazzi, S.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2023, 46 (04):
  • [37] Dependence of Low Gain Avalanche Detectors performance on neutron flux
    Howard, A.
    Cindro, V
    Hiti, B.
    Kramberger, G.
    Kljun, Z.
    Lastovicka-Medin, G.
    Mandic, I
    Mikuz, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 996
  • [38] RADIATION DETECTION PERFORMANCE OF VERY HIGH-GAIN AVALANCHE PHOTODIODES
    FARRELL, R
    VANDERPUYE, K
    CIRIGNANO, L
    SQUILLANTE, MR
    ENTINE, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3): : 176 - 179
  • [39] The CMS MTD Endcap Timing Layer: Precision timing with Low Gain Avalanche Diodes
    Ferrero, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1032
  • [40] Evaluation of different types of avalanche photo diodes from Hamamatsu and Perkin-Elmer
    Jiangui, L
    Fremout, A
    Bruyndonckx, P
    Tavernier, S
    Loude, JF
    Morel, C
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 873 - 875