Improving the experimental estimation of the incident angle modifier of evacuated tube solar collectors with heat pipes

被引:1
|
作者
Rodriguez-Munoz, J. M. [1 ]
Bove, I. [2 ]
Alonso-Suarez, R. [1 ,2 ]
机构
[1] Univ Republica, Dept Fis Litoral, Lab Energia Solar, CENUR Litoral Norte, Montevideo, Uruguay
[2] Univ Republica, Fac Ingn, Lab Energia Solar, Inst Fis, Montevideo, Uruguay
关键词
Solar thermal collector; Incident angle modifier; Evacuated tube; ISO; 9806; standard; DYNAMIC TEST METHOD; THERMAL PERFORMANCE; MODEL;
D O I
10.1016/j.renene.2024.121240
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This article focuses on the thermal performance testing of evacuated tube solar collectors with heat pipes (ETC-HP) using the ISO 9806:2017 standard test methods: Steady-state testing (SST) and Quasi-dynamic testing (QDT). The main objective of this work is to improve the experimental estimation of the incident angle modifier (IAM) for these types of solar collectors in both test methods. For the QDT method, a novel model for the IAM is presented and validated against SST results. This IAM model, recently developed for flat plate collectors under the SST framework, has demonstrated superior performance compared to other available models. This study marks its first application to ETC-HP technology, showcasing its adaptability across different technologies and test methods. While this work primarily focuses on ETC-HP collectors, the results are applicable to evacuated tubes in general. Thus, the generality of this model and its consistency with the SST method make it suitable for implementation in test standards as a general-purpose model. Regarding the SST method, and aiming to enhance consistency between testing methods, an improved parameter conversion from SST to QDT is also proposed, reducing IAM differences between test methods by 1 to 19 percentage points, with greater improvement at higher incidence angles.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] An up-to-date review on evacuated tube solar collectors
    Kumar, Arvind
    Said, Zafar
    Bellos, Evangelos
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2021, 145 (06) : 2873 - 2889
  • [32] Numerical analysis of evacuated tube solar collectors using nanofluids
    Mercan, Muhammed
    Yurddas, Ali
    SOLAR ENERGY, 2019, 191 : 167 - 179
  • [33] A note on estimation of diffuse radiation collected by all-glass evacuated solar tube collectors
    Zhang, Yougang
    Tang, Runsheng
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2021, 45 (10) : 15586 - 15594
  • [34] An up-to-date review on evacuated tube solar collectors
    Arvind Kumar
    Zafar Said
    Evangelos Bellos
    Journal of Thermal Analysis and Calorimetry, 2021, 145 : 2873 - 2889
  • [35] A study on incorporation of thermoelectric modules with evacuated-tube heat-pipe solar collectors
    He, Wei
    Su, Yuehong
    Wang, Y. Q.
    Riffat, S. B.
    Ji, Jie
    RENEWABLE ENERGY, 2012, 37 (01) : 142 - 149
  • [36] Experimental investigation of evacuated tube solar collector with annular heat exchanger
    Gowda, Narasimhe
    Gowda, B. Putta Bore
    Chandrashekar, R.
    Ugrasen, G.
    Keshavamurthy, R.
    DYNAMICS OF MACHINES AND MECHANISMS, INDUSTRIAL RESEARCH, 2014, 592-594 : 2355 - +
  • [37] Evacuated tube solar collectors integrated with phase change materials
    Papadimitratos, Alexios
    Sobhansarbandi, Sarvenaz
    Pozdin, Vladimir
    Zakhidov, Anvar
    Hassanipour, Fatemeh
    SOLAR ENERGY, 2016, 129 : 10 - 19
  • [38] Thermofluidics in Water-in-Glass Evacuated-Tube Solar Collectors Analysis Based on the Symmetry Conditions of Heat Flux and Tilt Angle
    Orbegoso, Elder M. Mendoza
    Alcantara, Josmell Alva
    Verastegui, Luis Julca
    Bengoa, Juan Carlos
    Marcelo-Aldana, Daniel
    Olivares, Raul La Madrid
    Kyprianidis, Konstantinos G.
    SYMMETRY-BASEL, 2025, 17 (01):
  • [39] Performance of evacuated tube solar collectors at high temperature differentials
    Barchyn, Dave
    Cenkowski, Stefan
    Canadian Biosystems Engineering / Le Genie des biosystems au Canada, 2015, 57 : 1 - 8
  • [40] Solar thermal networks operating with evacuated-tube collectors
    Martinez-Rodriguez, Guillermo
    Fuentes-Silva, Amanda L.
    Picon-Nunez, Martin
    ENERGY, 2018, 146 : 26 - 33