Concurrent validity of inertial measurement units in range of motion measurements of upper extremity: A systematic review and meta-analysis

被引:0
|
作者
Li, Jinfeng [1 ]
Qiu, Fanji [2 ]
Gan, Liaoyan [3 ]
Chou, Li-Shan [1 ]
机构
[1] Iowa State Univ, Dept Kinesiol, Ames, IA 50011 USA
[2] Humboldt Univ, Inst Sport Sci, Movement Biomech, Berlin, Germany
[3] Univ Alberta, Coll Hlth Sci, Fac Kinesiol Sport & Recreat, Edmonton, AB, Canada
来源
WEARABLE TECHNOLOGIES | 2024年 / 5卷
关键词
Inertial Measurement Unit (IMU); Movement Analysis; Upper Extremity; UPPER-LIMB; VALIDATION; KINEMATICS; ACCURACY; CAPTURE; REPEATABILITY; RELIABILITY; CALIBRATION;
D O I
10.1017/wtc.2024.6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Inertial measurement units (IMUs) have proven to be valuable tools in measuring the range of motion (RoM) of human upper limb joints. Although several studies have reported on the validity of IMUs compared to the gold standard (optical motion capture system, OMC), a quantitative summary of the accuracy of IMUs in measuring RoM of upper limb joints is still lacking. Thus, the primary objective of this systematic review and meta-analysis was to determine the concurrent validity of IMUs for measuring RoM of the upper extremity in adults. Fifty-one articles were included in the systematic review, and data from 16 were pooled for meta-analysis. Concurrent validity is excellent for shoulder flexion-extension (Pearson's r = 0.969 [0.935, 0.986], ICC = 0.935 [0.749, 0.984], mean difference = -3.19 (p = 0.55)), elbow flexion-extension (Pearson's r = 0.954 [0.929, 0.970], ICC = 0.929 [0.814, 0.974], mean difference = 10.61 (p = 0.36)), wrist flexion-extension (Pearson's r = 0.974 [0.945, 0.988], mean difference = -4.20 (p = 0.58)), good to excellent for shoulder abduction-adduction (Pearson's r = 0.919 [0.848, 0.957], ICC = 0.840 [0.430, 0.963], mean difference = -7.10 (p = 0.50)), and elbow pronation-supination (Pearson's r = 0.966 [0.939, 0.981], ICC = 0.821 [0.696, 0.900]). There are some inconsistent results for shoulder internal-external rotation (Pearson's r = 0.939 [0.894, 0.965], mean difference = -9.13 (p < 0.0001)). In conclusion, the results support IMU as a viable instrument for measuring RoM of upper extremity, but for some specific joint movements, such as shoulder rotation and wrist ulnar-radial deviation, IMU measurements need to be used with caution.
引用
收藏
页数:35
相关论文
共 50 条
  • [41] Validity and reliability of inertial measurement units used to measure motion of the lumbar spine: A systematic review of individuals with and without low back pain
    Mcclintock, Frederick A.
    Callaway, Andrew J.
    Clark, Carol J.
    Williams, Jonathan M.
    MEDICAL ENGINEERING & PHYSICS, 2024, 126
  • [42] How do digital range of motion measurement devices 'measure-up' to traditional goniometry in assessing shoulder range of motion? A systematic review and meta-analysis
    Shepherd, J.
    Hansjee, S.
    Divall, P.
    Raval, P.
    Singh, H. P.
    SHOULDER & ELBOW, 2024, 16 (04) : 363 - 381
  • [43] Reliability and Concurrent Validity of the SARC-F and Its Modified Versions: A Systematic Review and Meta-Analysis
    Voelker, Stefanie N.
    Michalopoulos, Nikolaos
    Maier, Andrea B.
    Reijnierse, Esmee M.
    JOURNAL OF THE AMERICAN MEDICAL DIRECTORS ASSOCIATION, 2021, 22 (09) : 1864 - +
  • [44] Concurrent Validity of Virtual Reality-Based Assessment of Executive Function: A Systematic Review and Meta-Analysis
    Lee, Si-An
    Kim, Ji-Yea
    Park, Jin-Hyuck
    JOURNAL OF INTELLIGENCE, 2024, 12 (11)
  • [45] Concurrent validity of the alcohol purchase task in relation to alcohol involvement: protocol for a systematic review and meta-analysis
    Gonzalez-Roz, Alba
    Martinez-Loredo, Victor
    Secades-Villa, Roberto
    Amlung, Michael
    MacKillop, James
    BMJ OPEN, 2020, 10 (06):
  • [46] Analysis of the Active Measurement Systems of the Thoracic Range of Movements of the Spine: A Systematic Review and a Meta-Analysis
    Esteban-Gonzalez, Pablo
    Sanchez-Romero, Eleuterio A.
    Villafane, Jorge Hugo
    SENSORS, 2022, 22 (08)
  • [47] Impact of concomitant upper-extremity injuries in patients with hip fractures: a systematic review and meta-analysis
    Kim, Han Soul
    Lee, Jung Eun
    Choi, Rak Jun
    Kim, Chul-Ho
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (07) : 3795 - 3802
  • [48] Efficacy of Neurostimulations for Upper Extremity Function Recovery after Stroke: A Systematic Review and Network Meta-Analysis
    Xue, Tao
    Yan, Zeya
    Meng, Jiahao
    Wang, Wei
    Chen, Shujun
    Wu, Xin
    Gu, Feng
    Tao, Xinyu
    Wu, Wenxue
    Chen, Zhouqing
    Bai, Yutong
    Wang, Zhong
    Zhang, Jianguo
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (20)
  • [49] Cerebrovascular Complications After Upper Extremity Access for Complex Aortic Interventions: A Systematic Review and Meta-Analysis
    Meertens, Max M.
    Lemmens, Charlotte C.
    Oderich, Gustavo S.
    Schurink, Geert W. H.
    Mees, Barend M. E.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2020, 43 (02) : 186 - 195
  • [50] Impact of concomitant upper-extremity injuries in patients with hip fractures: a systematic review and meta-analysis
    Han Soul Kim
    Jung Eun Lee
    Rak Jun Choi
    Chul-Ho Kim
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3795 - 3802