Concurrent validity of inertial measurement units in range of motion measurements of upper extremity: A systematic review and meta-analysis

被引:0
|
作者
Li, Jinfeng [1 ]
Qiu, Fanji [2 ]
Gan, Liaoyan [3 ]
Chou, Li-Shan [1 ]
机构
[1] Iowa State Univ, Dept Kinesiol, Ames, IA 50011 USA
[2] Humboldt Univ, Inst Sport Sci, Movement Biomech, Berlin, Germany
[3] Univ Alberta, Coll Hlth Sci, Fac Kinesiol Sport & Recreat, Edmonton, AB, Canada
来源
WEARABLE TECHNOLOGIES | 2024年 / 5卷
关键词
Inertial Measurement Unit (IMU); Movement Analysis; Upper Extremity; UPPER-LIMB; VALIDATION; KINEMATICS; ACCURACY; CAPTURE; REPEATABILITY; RELIABILITY; CALIBRATION;
D O I
10.1017/wtc.2024.6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Inertial measurement units (IMUs) have proven to be valuable tools in measuring the range of motion (RoM) of human upper limb joints. Although several studies have reported on the validity of IMUs compared to the gold standard (optical motion capture system, OMC), a quantitative summary of the accuracy of IMUs in measuring RoM of upper limb joints is still lacking. Thus, the primary objective of this systematic review and meta-analysis was to determine the concurrent validity of IMUs for measuring RoM of the upper extremity in adults. Fifty-one articles were included in the systematic review, and data from 16 were pooled for meta-analysis. Concurrent validity is excellent for shoulder flexion-extension (Pearson's r = 0.969 [0.935, 0.986], ICC = 0.935 [0.749, 0.984], mean difference = -3.19 (p = 0.55)), elbow flexion-extension (Pearson's r = 0.954 [0.929, 0.970], ICC = 0.929 [0.814, 0.974], mean difference = 10.61 (p = 0.36)), wrist flexion-extension (Pearson's r = 0.974 [0.945, 0.988], mean difference = -4.20 (p = 0.58)), good to excellent for shoulder abduction-adduction (Pearson's r = 0.919 [0.848, 0.957], ICC = 0.840 [0.430, 0.963], mean difference = -7.10 (p = 0.50)), and elbow pronation-supination (Pearson's r = 0.966 [0.939, 0.981], ICC = 0.821 [0.696, 0.900]). There are some inconsistent results for shoulder internal-external rotation (Pearson's r = 0.939 [0.894, 0.965], mean difference = -9.13 (p < 0.0001)). In conclusion, the results support IMU as a viable instrument for measuring RoM of upper extremity, but for some specific joint movements, such as shoulder rotation and wrist ulnar-radial deviation, IMU measurements need to be used with caution.
引用
收藏
页数:35
相关论文
共 50 条
  • [1] Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis
    Ziwei Zeng
    Yue Liu
    Xiaoyue Hu
    Meihua Tang
    Lin Wang
    Sports Medicine - Open, 2022, 8
  • [2] Validity and Reliability of Inertial Measurement Units on Lower Extremity Kinematics During Running: A Systematic Review and Meta-Analysis
    Zeng, Ziwei
    Liu, Yue
    Hu, Xiaoyue
    Tang, Meihua
    Wang, Lin
    SPORTS MEDICINE-OPEN, 2022, 8 (01)
  • [3] Validity of inertial measurement units for tracking human motion: a systematic review
    Ghattas, John
    Jarvis, Danielle N.
    SPORTS BIOMECHANICS, 2021,
  • [4] Upper limb assessment with inertial measurement units according to the international classification of functioning in stroke: a systematic review and correlation meta-analysis
    Cinnera, Alex Martino
    Picerno, Pietro
    Bisirri, Alessio
    Koch, Giacomo
    Morone, Giovanni
    Vannozzi, Giuseppe
    TOPICS IN STROKE REHABILITATION, 2024, 31 (01) : 66 - 85
  • [5] Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
    Al-Amri, Mohammad
    Nicholas, Kevin
    Button, Kate
    Sparkes, Valerie
    Sheeran, Liba
    Davies, Jennifer L.
    SENSORS, 2018, 18 (03):
  • [6] Concurrent Validity Of Inertial Measurement Units With 3D Motion Analysis System For Joint Kinematics
    Balardi, Kathryn
    Johnson, Michael
    Ross, Jaclyn
    Chinworth, Susan
    Vallabhajosula, Srikant
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2021, 53 (08): : 130 - 131
  • [7] Shoulder Range of Motion Measurement Using Inertial Measurement Unit-Concurrent Validity and Reliability
    Kaszynski, Jakub
    Baka, Cezary
    Bialecka, Martyna
    Lubiatowski, Przemyslaw
    SENSORS, 2023, 23 (17)
  • [8] Reliability and validity varies among smartphone apps for range of motion measurements of the lower extremity: a systematic review
    Hahn, Sarah
    Kroeger, Inga
    Willwacher, Steffen
    Augat, Peter
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2021, 66 (06): : 537 - 555
  • [9] Validity and Reliability of Inertial Measurement Units in Active Range of Motion Assessment in the Hip Joint
    Stolowski, Lukasz
    Niedziela, Maciej
    Lubiatowski, Bartlomiej
    Lubiatowski, Przemyslaw
    Piontek, Tomasz
    SENSORS, 2023, 23 (21)
  • [10] Systematic Review and Meta-Analysis of Global Neuroma Incidence in Upper Extremity Amputees
    Chaker, Sara C.
    Hung, Ya-Ching
    Saad, Mariam
    Cardenas, David
    Perdikis, Galen
    Thayer, Wesley P.
    ANNALS OF PLASTIC SURGERY, 2024, 92 (01) : 80 - 85