Study on Wind Vibration Response and Coupling Effect of Transmission Tower-Line System Under Downburst

被引:2
|
作者
Zhong, Yongli [1 ]
Liu, Yichen [1 ]
Li, Shun [2 ]
Yan, Zhitao [1 ,3 ]
Liu, Xinpeng [1 ]
机构
[1] Chongqing Univ Sci & Technol, Sch Civil Engn & Architecture, Chongqing 401331, Peoples R China
[2] Chongqing IAT Automobile Res Inst Co Ltd, Chongqing 401121, Peoples R China
[3] Chongqing Univ, Sch Civil Engn, Chongqing 400045, Peoples R China
来源
IEEE ACCESS | 2024年 / 12卷
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Poles and towers; Couplings; Wind speed; Vibrations; History; Atmospheric modeling; Numerical models; Computational fluid dynamics; Downburst; computational fluid dynamics (CFD); transmission tower-line system; wind-induced vibration response; tower-line coupling effect; NUMERICAL-SIMULATION; MICROBURST; TORNADO;
D O I
10.1109/ACCESS.2024.3422032
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Downburst is a type of near-surface short-term destructive strong wind that significantly affects wind-sensitive flexible structures like transmission tower-line systems. The existence of the tower-line coupling effect complicates the wind-induced vibration response analysis. Firstly, the average wind speed time history is obtained using the impinging jet wind field model, the pulsating wind speed time history is simulated using the harmonic synthesis method, and then the total wind speed time history of the downburst is obtained by superposition. Then, the transmission tower-line finite element model is established to carry out the wind vibration response analysis under different wind attack angles. Based on the most unfavorable wind angle of attack, the wind-induced vibration response and the coupling effect of the tower-line system are investigated under different maximum wind speed heights (Z(max)) and span distances. Finally, the range of wind load reduction coefficients for the tower-line separation system is given. The results show that under the most unfavorable wind angle of attack angle, both the displacement and acceleration response of the tower-line separation system are more significant than that of the tower-line coupling system. At Z(max )= 70m, the difference in displacement response between the two systems reaches the maximum, indicating an apparent tower-line coupling effect. As the span distance increases, both the displacement response and the acceleration response of the tower-line separation system increase. In contrast, the displacement response of the tower-line coupling system increases, but the acceleration response decreases. For the proposed design reduction coefficient for the transmission tower-line coupling effect under the action of the downburst, it is considered more reasonable to take the value between 0.83-0.95. This study provides some references for further optimization of the transmission tower design.
引用
收藏
页码:100120 / 100133
页数:14
相关论文
共 50 条
  • [41] Fragility analysis of a long-span transmission tower-line system under wind loads
    Tian, Li
    Zhang, Xin
    Fu, Xing
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (10) : 2110 - 2120
  • [42] Wind induced response numerical simulation of a transmission tower-line system in real mountainous terrain
    Liu M.
    Lü H.
    Luo K.
    Wang M.
    Fan J.
    Chi W.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2020, 39 (24): : 232 - 239
  • [43] Wind-induced response mitigation of transmission tower-line system by using magnetorheological dampers
    Hubei Key Laboratory of Roadway Bridge and Structural Engineering, Wuhan University of Technology, Wuhan 430070, China
    不详
    J Vib Shock, 2008, 3 (71-74):
  • [44] Wind fragility assessment and sensitivity analysis for a transmission tower-line system
    Wang, Jia
    Li, Hong-Nan
    Fu, Xing
    Dong, Zhi-Qian
    Sun, Zhi-Guo
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2022, 231
  • [45] CONTROL OF WIND-INDUCED RESPONSE OF TRANSMISSION TOWER-LINE SYSTEM BY USING MAGNETORHEOLOGICAL DAMPERS
    Chen, Bo
    Zheng, Jin
    Qu, Weilian
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2009, 9 (04) : 661 - 685
  • [46] Strong wind-induced vibration analyses of uncoupled transmission tower-line model
    Zhang, Wentong
    Xiao, Yiqing
    Li, Chao
    2020 5TH ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2020), 2020, : 1898 - 1902
  • [47] Wind tunnel test on wind-induced response of transmission tower and tower line coupling system
    Zhao, Guifeng
    Xie, Qiang
    Liang, Shuguo
    Li, Jie
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2010, 31 (02): : 69 - 77
  • [48] Prediction on coupled transmission tower-line system dynamic response under strong wind based on support vector regression
    Wu, Chuan
    Zhang, Bo
    Liu, Zehui
    Yang, Xiaohui
    Li, Chao
    Fu, Peng
    Zhao, Yang
    ENERGY REPORTS, 2022, 8 : 260 - 269
  • [49] Effect of occluding hills on wind-induced fatigue of transmission tower-line coupled system
    Zhang, Chun-Tao
    Li, Zheng-Liang
    Fan, Wen-Liang
    Wang, Zhi-Song
    Sun, Yi
    Zhendong yu Chongji/Journal of Vibration and Shock, 2013, 32 (10): : 184 - 191
  • [50] Energy property of the controlled-vibration produced by wind in transmission tower-line systems
    Chen, Bo
    Zheng, Jin
    Qu, Weilian
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2009, 37 (02): : 121 - 124