Distribution and propagation of stress and strain in cube honeycombs as trabecular bone substitutes: Finite element model analysis

被引:0
|
作者
Wang, Guangxin [1 ]
Liu, Jiaqi [1 ]
Lian, Tingting [1 ]
Sun, Yanyan [1 ,4 ]
Chen, Xuewen [1 ]
Todo, Mitsugu [2 ]
Osaka, Akiyoshi [1 ,3 ]
机构
[1] Henan Univ Sci & Technol, Sch Mat Sci & Engn, Luoyang 471023, Henan, Peoples R China
[2] Kyushu Univ, Res Inst Appl Mech, Kasuga 8168580, Japan
[3] Okayama Univ, Fac Engn, Tsushima, Okayama 7008530, Japan
[4] Nanjing Univ, Sch Engn & Appl Sci, Nanjing 210023, Jiangsu, Peoples R China
关键词
Trabecular bone; Cube honeycomb; FEM simulation; Strut removal; Percolation; MECHANICAL-PROPERTIES; APATITE FORMATION; STAINLESS-STEEL; IMPLANTS; BEHAVIOR; POROSITY; ABILITY; LAYERS;
D O I
10.1016/j.jmbbm.2024.106647
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
For designing trabecular (Tb) bone substitutes suffering from osteoporosis, finite element model (FEM) simulations were conducted on honeycombs (HCs) of 8 x 8 x 1 (2D) and 8 x 8 x 8 (3D) assemblies of cube cellular units consisting of 0.9 mm long Nylon (R) (R) 66 (PA, Young's modulus E: 2.83 GPa) and polyethylene (PE, E: 1.1 GPa) right square prisms. Osteoporotic damage to the Tb bone was simulated by removing the inner vertical struts (pillars; the number of removed pillars: Delta n <= 300) and by thinning the strut (thickness, d: 0.4-0.1 mm), while the six facade lattices were kept flawless. Uniform and uniaxial compressive loads on the HCs induced elastic deformation of the struts. The pillars held almost all the load, while the horizontal struts (beams) shared little. E for PA 3D HCs of all d smoothly decreased with Delta n. PA 3D HCs of 0.2 mm struts deserved to be the substitutes for Tb bone, while PE 3D HCs of 0.05 mm struts were only for the Tb bone of the poorest bone quality. For the PA 3D HCs, the maximum von Mises stress (sigma M) M ) first rapidly increased with Delta n and showed a break at Delta n 50, then gradually approached the yield stress of PA (50 MPa). Moreover, small portions of the stress were transferred from the fa & ccedil;ade pillars to the adjacent inner beams, especially those near the lost-pillar sites, denoted as X defects. The floor beams of thinner struts associated with the X-defects were lifted, and similar lifting effects in smaller amounts were propagated to the other floors. The 3DHCs of the thicker struts showed no such flexural deformations. The concept of force percolation through the remaining struts was proposed to interpret those mechanical behaviors of the HCs.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] FINITE ELEMENT ANALYSIS OF A THREE-DIMENSIONAL OPEN-CELLED MODEL FOR TRABECULAR BONE.
    Beaupre, G.S.
    Hayes, W.C.
    Journal of Biomechanical Engineering, 1985, 107 (03) : 249 - 356
  • [22] FINITE-ELEMENT ANALYSIS OF A 3-DIMENSIONAL OPEN-CELLED MODEL FOR TRABECULAR BONE
    BEAUPRE, GS
    HAYES, WC
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1985, 107 (03): : 249 - 256
  • [23] Comparison of Stress and Strain Distribution Patterns in Canine Implant and Maxillary Bone in Three Occlusal Schemes Using Finite Element Analysis
    Fathi, Amirhossein
    Hoshyar, Younes
    Ebadian, Behnaz
    Ghorbani, Mahsa
    EUROPEAN JOURNAL OF DENTISTRY, 2024, 18 (03) : 852 - 859
  • [24] Influence of Implant Collar Design on Stress and Strain Distribution in the Crestal Compact Bone: A Three-Dimensional Finite Element Analysis
    Shen, Wan-Ling
    Chen, Chen-Sheng
    Hsu, Ming-Lun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (05) : 901 - 910
  • [25] Finite element analysis of stress distribution on reconstructed mandibular models for autogenous bone grafts
    Kucukguven, Meric Bilgic
    Akkocaoglu, Murat
    TECHNOLOGY AND HEALTH CARE, 2020, 28 (03) : 249 - 258
  • [26] Trabecular bone strength with virtual osteoporotic simulation and finite element analysis.
    Ferreri, S
    Mittra, E
    Gruber, B
    Oin, Y
    JOURNAL OF BONE AND MINERAL RESEARCH, 2004, 19 : S224 - S224
  • [27] Simulation of vertebral trabecular bone loss using voxel finite element analysis
    Mc Donnell, P.
    Harrison, N.
    Liebschner, M. A. K.
    Mc Hugh, P. E.
    JOURNAL OF BIOMECHANICS, 2009, 42 (16) : 2789 - 2796
  • [28] Trabecular bone fracture healing simulation with finite element analysis and fuzzy logic
    Shefelbine, SJ
    Augat, P
    Claes, L
    Simon, U
    JOURNAL OF BIOMECHANICS, 2005, 38 (12) : 2440 - 2450
  • [29] Finite Element Analysis of Bone Stress After SARPE
    Ferreira Rubim de Assis, Diogo Souza
    Xavier, Tathy Aparecida
    Noritomi, Pedro Yoshito
    Goncales, Eduardo Sanches
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2014, 72 (01) : 167.e1 - 167.e7
  • [30] Influence of Trabecular Bone on Peri-Implant Stress and Strain Based on Micro-CT Finite Element Modeling of Beagle Dog
    Liao, Sheng-hui
    Zhu, Xing-hao
    Xie, Jing
    Sohodeb, Vikesh Kumar
    Ding, Xi
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016