Evaluation of image-guided and surface-guided radiotherapy for breast cancer patients treated in deep inspiration breath-hold: A single institution experience

被引:19
|
作者
Penninkhof, Joan [1 ]
Fremeijer, Kimm [1 ]
Harten, Kirsten Offereins-van [1 ]
van Wanrooij, Cynthia [1 ]
Quint, Sandra [1 ]
Kunnen, Britt [1 ]
Hoffmans-Holtzer, Nienke [1 ]
Swaak, Annemarie [1 ]
Baaijens, Margreet [1 ]
Dirkx, Maarten [1 ]
机构
[1] Erasmus MC, Canc Inst, Dept Radiat Oncol, Dr Molewaterpl 40, NL-3015 GD Rotterdam, Netherlands
来源
TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY | 2022年 / 21卷
关键词
Breath; -hold; Surface -guided radiotherapy; DIBH; Breast; REPRODUCIBILITY; IRRADIATION; STABILITY; ACCURACY; SETUP; DIBH;
D O I
10.1016/j.tipsro.2022.02.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Nowadays, deep inspiratory breath-hold is a common technique to reduce heart dose in left-sided breast radiotherapy. This study evaluates the evolution of the breath-hold technique in our institute, from portal imaging during dose delivery to continuous monitoring with surface-guided radiotherapy (SGRT). Materials and methods: Setup data and portal imaging results were analyzed for 98 patients treated before 2014, and SGRT data for 228 patients treated between 2018 and 2020. For the pre-SGRT group, systematic and random setup errors were calculated for different correction protocols. Residual errors and reproducibility of breathholds were evaluated for both groups. The benefit of using SGRT for initial positioning was evaluated for another cohort of 47 patients. Results: Online correction reduced the population mean error from 3.9 mm (no corrections) to 1.4 mm. Despite online setup correction, deviations greater than 3 mm were observed in about 10% and 20% of the treatment beams in ventral-dorsal and cranial-caudal directions, respectively. However, these percentages were much smaller than with offline protocols or no corrections. Mean absolute differences between breath-holds within a fraction were smaller in the SGRT-group (1.69 mm) than in the pre-SGRT-group (2.10 mm), and further improved with addition of visual feedback (1.30 mm). SGRT for positioning did not improve setup accuracy, but slightly reduced the time for imaging and setup correction, allowing completion within 3.5 min for 95% of fractions. Conclusion: For accurate radiotherapy breast treatments using deep inspiration breath-hold, daily imaging and correction is required. SGRT provides accurate information on patient positioning during treatment and improves patient compliance with visual feedback.
引用
收藏
页码:51 / 57
页数:7
相关论文
共 50 条
  • [41] Dosimetric and clinical advantages of deep inspiration breath-hold (DIBH) during radiotherapy of breast cancer
    Vicente Bruzzaniti
    Armando Abate
    Paola Pinnarò
    Marco D’Andrea
    Erminia Infusino
    Valeria Landoni
    Antonella Soriani
    Carolina Giordano
    Anna Maria Ferraro
    Lidia Strigari
    Journal of Experimental & Clinical Cancer Research, 32
  • [42] Dosimetric and clinical advantages of deep inspiration breath-hold (DIBH) during radiotherapy of breast cancer
    Bruzzaniti, Vicente
    Abate, Armando
    Pinnaro, Paola
    D'Andrea, Marco
    Infusino, Erminia
    Landoni, Valeria
    Soriani, Antonella
    Giordano, Carolina
    Ferraro, Anna Maria
    Strigari, Lidia
    JOURNAL OF EXPERIMENTAL & CLINICAL CANCER RESEARCH, 2013, 32
  • [43] Target position uncertainty during visually guided deep-inspiration breath-hold radiotherapy in locally advanced lung cancer
    Rydhog, Jonas Scherman
    de Blanck, Steen Riisgaard
    Josipovic, Mirjana
    Jolck, Rasmus Irming
    Larsen, Klaus Richter
    Clementsen, Paul
    Andersen, Thomas Lars
    Poulsen, Per Rugaard
    Persson, Gitte Fredberg
    af Rosenschold, Per Munck
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 (01) : 78 - 84
  • [44] Postoperative radiotherapy for right breast cancer with regional nodal irradiation utilizing the surface-guided radiotherapy based deep inspiration breath hold technique on a TrueBeam HD linear accelerator: A case report
    Li, Chao
    Wu, Dang
    Guo, Siyu
    Zhang, Bicheng
    Wei, Qichun
    Zhang, Ting
    MEDICAL DOSIMETRY, 2025, 50 (01) : 13 - 18
  • [45] Selection of patients with left breast cancer for IMRT with deep inspiration breath-hold technique
    Chang, Chih-shen
    Chen, Chia-hsin
    Liu, Kuo-chi
    Ho, Chia-sheng
    Chen, Miao-fen
    JOURNAL OF RADIATION RESEARCH, 2020, 61 (03) : 431 - 439
  • [46] Setup accuracy and residual motion in daily image guided treatment of breast patients in deep inspiration breath hold
    Thomsen, M. S.
    Lutz, C. M.
    Fledelius, W.
    Offersen, B.
    Poulsen, P. R.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S88 - S88
  • [47] Deep inspiration breath-hold for cardioprotection in patients with left-sided breast cancer
    Micke, O.
    Muecke, R.
    Kister, K.
    Schaefer, U.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S506 - S506
  • [48] Voluntary deep-inspiration breath-hold radiotherapy for left sided breast cancer patients - first clinical results of a fluoroscopy guided method with retrospectively dose calculation
    Borst, G. R.
    Elkhuizen, P. E.
    Betgen, A.
    Minkema, D.
    Russell, N. S.
    Giersbergen, A.
    Bartelink, H.
    van Vliet-Vroegindeweij, C.
    Sonke, J. J.
    EJC SUPPLEMENTS, 2008, 6 (07): : 145 - 145
  • [49] Evaluation of target and cardiac position during visually monitored deep inspiration breath-hold for breast radiotherapy
    Conroy, Leigh
    Yeung, Rosanna
    Watt, Elizabeth
    Quirk, Sarah
    Long, Karen
    Hudson, Alana
    Tien Phan
    Smith, Wendy L.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 25 - 36
  • [50] Image-guided interstitial brachytherapy for recurrent cervical cancer after radiotherapy: A single institution experience
    Ren, Xiaojun
    Fu, Yingli
    Liu, Zhongshan
    Lin, Xia
    Qiu, Ling
    Li, Yunfeng
    Li, Hanyang
    Bai, Yuqi
    Wang, Tiejun
    FRONTIERS IN ONCOLOGY, 2022, 12