A Novel ECG Signal Quality Index Method Based on Skewness-MODWT Analysis

被引:1
|
作者
Tai, Ta Viet [1 ]
Tan, Ma Pham Nhut [1 ]
Tien, Duong Hoang [1 ]
Ha, Nguyen Viet [1 ]
Hoang, Trong-Thuc [2 ]
Pham, Cong-Kha [2 ]
Nguyen, Tran Thi Thao [1 ]
机构
[1] Vietnam Natl Univ Ho Chi Minh City, Univ Sci, Fac Elect Telecommun, Ho Chi Minh City 700000, Vietnam
[2] Univ Electrocommun UEC, Dept Comp & Network Engn, Tokyo 1828585, Japan
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Electrocardiography; Indexes; Reactive power; Wearable devices; Noise measurement; Volume measurement; Electrocardiogram (ECG); exponentially weighted mean-variance (EWMV); maximal overlap discrete wavelet transform (MODWT); signal quality indices (SQIs); wearable devices;
D O I
10.1109/ACCESS.2024.3401708
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Wearable devices have gained significant popularity for continuous Electrocardiogram (ECG) monitoring due to their compactness and convenience. Day-by-day and 24/7 monitoring without gaps is demanded to promptly detect unusual symptoms that are short-term warning signs of dangerous diseases. Cost-saving criteria are the highest priority to extend the use time of devices and maintain the system operation. However, not all measured signals are useful because the signal quality will be affected by many things such as motion artifacts and muscle noise. Demands on classifying and sending only the usable signal is a requirement, it can save the battery on wearable devices and the expense on the server side (i.e., cloud-based processing), such as storage and processing resources. Therefore, Signal Quality Indices (SQIs) have been developed and researched to determine signal quality to meet the above requirements. This study introduces a novel SQI approach to classify signals. The proposed method has three contributions: 1) exponentially Weighted Mean-Variance (EWMV), a lightweight equation, to identify peaks, followed by applying an adaptive threshold to define peaks that have the same shape as R-peaks; 2) outlier elimination process is proposed to enhance the accuracy; and 3) maximal Overlap Discrete Wavelet Transform (MODWT) is employed to categorize ECG signals into a new class, potentially containing signals relevant to pathological analysis. Experimental results demonstrate that our algorithm achieves the highest sensitivity for both noisy and noiseless data sets. Specifically, it achieved a sensitivity of 99.31% for clean signals and 97.69% for noisy signals. In the case of the PhysioNet challenge data set, while our sensitivity of 96.37% may not be the highest, our accuracy stands out at 95.10%, surpassing other methods recently reviewed. Additionally, our approach demonstrates the lowest trade-off between sensitivity and accuracy among the surveyed SQI techniques.
引用
收藏
页码:70184 / 70197
页数:14
相关论文
共 50 条
  • [31] Toward ECG-based analysis of hypertrophic cardiomyopathy: a novel ECG segmentation method for handling abnormalities
    Nezamabadi, Kasra
    Mayfield, Jacob
    Li, Pengyuan
    Greenland, Gabriela, V
    Rodriguez, Sebastian
    Simsek, Bahadir
    Mousavi, Parvin
    Shatkay, Hagit
    Abraham, M. Roselle
    JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2022, 29 (11) : 1879 - 1889
  • [32] Analysis Method for GNSS Signal Quality Based on Constellation Diagram
    Wang, Ying
    Su, Zhe
    Meng, Yansong
    Tao, Xiaoxia
    CHINA SATELLITE NAVIGATION CONFERENCE (CSNC) 2014 PROCEEDINGS, VOL I, 2014, 303 : 315 - 326
  • [33] A Novel Method for the Conversion of Scanned Electrocardiogram (ECG) Image to Digital Signal
    Lewis, Macline Crecsilla
    Maiya, Manjunatha
    Sampathila, Niranjana
    INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING AND APPLICATIONS, ICICA 2016, 2018, 632 : 363 - 373
  • [34] A signal quality assessment-based ECG waveform delineation method used for wearable monitoring systems
    Xie, Jialing
    Peng, Li
    Wei, Liang
    Gong, Yushun
    Zuo, Feng
    Wang, Juan
    Yin, Changlin
    Li, Yongqin
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2021, 59 (10) : 2073 - 2084
  • [35] A novel ECG signal classification method using DEA-ELM
    Diker, Aykut
    Avci, Engin
    Tanyildizi, Erkan
    Gedikpinar, Mehmet
    MEDICAL HYPOTHESES, 2020, 136
  • [36] A novel method for detecting R-peaks in electrocardiogram (ECG) signal
    Manikandan, M. Sabarimalai
    Soman, K. P.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2012, 7 (02) : 118 - 128
  • [37] Signal Quality Index Estimator for Complex-Lead type ECG beat detectors
    Hintermüller, Christoph
    Blessberger, Hermann
    Steinwender, Clemens
    Current Directions in Biomedical Engineering, 2024, 10 (03)
  • [38] A novel signal feature extraction method based on wavelet analysis
    Wang, Xin
    WCICA 2006: SIXTH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-12, CONFERENCE PROCEEDINGS, 2006, : 4967 - 4971
  • [39] ECG signal denoising based on deep factor analysis
    Wang, Ge
    Yang, Lin
    Liu, Ming
    Yuan, Xin
    Xiong, Peng
    Lin, Feng
    Liu, Xiuling
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 57
  • [40] Accelerometer based motion noise analysis of ECG signal
    Han, D. K.
    Hong, J. H.
    Shin, J. Y.
    Lee, T. S.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 5, 2009, 25 : 198 - +