Identifying gastric cancer by optical coherence tomography based on an optimized depth-resolved attenuation estimation

被引:0
|
作者
Zhao, Chao [1 ,2 ]
Shu, Yukang [1 ,2 ]
Cui, Lin [3 ]
He, Xiang [1 ,2 ]
Mao, Weizheng [4 ]
Shi, Xiaofeng [1 ,2 ]
Zhao, Hang [1 ,2 ]
Ma, Jun [1 ,2 ]
机构
[1] Ocean Univ China, Opt & Optoelect Lab, Qingdao 266100, Peoples R China
[2] Ocean Univ China, Engn Res Ctr Adv Marine Phys Instruments & Equipme, Minist Educ, Qingdao 266100, Peoples R China
[3] Qingdao Municipal Hosp, Dept Pathol, Qingdao 266011, Shandong, Peoples R China
[4] Qingdao Municipal Hosp, Dept Gen Surg, Qingdao 266011, Shandong, Peoples R China
关键词
optical coherence tomography; gastric cancer; optimized depth resolution estimation; COEFFICIENTS; ENDOSCOPY; MODEL;
D O I
10.1088/2040-8986/ad5456
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical coherence tomography (OCT) is a reliable technique for cancer detection, with the potential to improve accuracy in identifying cancerous tissue through effective use of OCT image data. We proposed an optimized depth resolution estimation based optical attenuation coefficient (OAC) mapping method to reduce the error effect caused by discretization without considering whether the light is completely attenuated or not. The attenuation coefficient maps of gastric tissue were reconstructed using this method. Features were extracted from these maps using gray-level co-occurrence matrix and gray histogram, and a support vector machine was employed as a classifier for identifying gastric cancer tissues. The recognition accuracy achieved was 98.60%, which was higher than the 94.30% accuracy in the control group without OACs. This approach enhances the utilization of OCT image information and improves its practical application ability by increasing the recognition accuracy.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Depth-resolved method for attenuation coefficient calculation from optical coherence tomography data for improved biological structure visualization
    Moiseev, Alexander
    Sherstnev, Evgeny
    Kiseleva, Elena
    Achkasova, Ksenia
    Potapov, Arseniy
    Yashin, Konstantin
    Sirotkina, Marina
    Gelikonov, Grigory
    Matkivsky, Vasily
    Shilyagin, Pavel
    Ksenofontov, Sergey
    Bederina, Evgenia
    Medyanik, Igor
    Zagaynova, Elena
    Gladkova, Natalia
    JOURNAL OF BIOPHOTONICS, 2023, 16 (12)
  • [22] Depth-resolved photothermal optical coherence tomography by local optical path length change measurement
    Makita, Shuichi
    Hong, Young-Joo
    Li, En
    Yoshiaki, Yasuno
    OPTICAL ELASTOGRAPHY AND TISSUE BIOMECHANICS III, 2016, 9710
  • [23] RECONSTRUCTION OF DEPTH-RESOLVED FIBER ORIENTATIONS IN THE BRAIN WITH POLARIZATION SENSITIVE OPTICAL COHERENCE TOMOGRAPHY
    Wang, H.
    Boas, D.
    Akkin, T.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2016, 36 : 388 - 389
  • [24] Extraction and compensation for depth-resolved phase error in spectral domain optical coherence tomography
    Zhang, Xianling
    Gao, Wanrong
    Chen, Chaoliang
    Bian, Haiyi
    Zhu, Yue
    Zhongguo Jiguang/Chinese Journal of Lasers, 2014, 41 (02):
  • [25] An Optimized Depth-Resolved Dispersion Compensation Method in Optical Coherent Tomography Signal Processing
    Zhang, Xi
    Li, Zhongliang
    Nan, Nan
    Wang, Xiangzhao
    FOURTH INTERNATIONAL CONFERENCE ON PHOTONICS AND OPTICAL ENGINEERING, 2021, 11761
  • [26] Techniques for extraction of depth-resolved in vivo human retinal intrinsic optical signals with optical coherence tomography
    Tumlinson, Alexandre R.
    Hermann, Boris
    Hofer, Bernd
    Povazay, Boris
    Margrain, Tom H.
    Binns, Alison M.
    Drexler, Wolfgang
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2009, 53 (04) : 315 - 326
  • [27] Techniques for extraction of depth-resolved in vivo human retinal intrinsic optical signals with optical coherence tomography
    Alexandre R. Tumlinson
    Boris Hermann
    Bernd Hofer
    Boris Považay
    Tom H. Margrain
    Alison M. Binns
    Wolfgang Drexler
    Japanese Journal of Ophthalmology, 2009, 53 : 315 - 326
  • [28] Absolute depth-resolved optic axis measurement with catheter-based polarization sensitive optical coherence tomography
    Masoumi, Shadi
    Lee, Jaeyul
    Jones, Georgia L.
    Quemener, Mireille
    Parent, Martin
    Bouma, Brett E.
    Hariri, Lida P.
    Cote, Daniel C.
    Villiger, Martin
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (12): : 6957 - 6976
  • [29] Depth-resolved dispersion compensation method for optical coherence tomography imaging based on rectangular window function optimization
    Zhang, Xi
    Li, Zhongliang
    Nan, Nan
    Wang, Xiangzhao
    JOURNAL OF MODERN OPTICS, 2022, 69 (15) : 827 - 837
  • [30] Depth-Resolved Physiological Response of Retina to Transcorneal Electrical Stimulation Measured With Optical Coherence Tomography
    Sun, Pengcheng
    Li, Qian
    Li, Heng
    Di, Liqing
    Su, Xiaofan
    Chen, Jianpin
    Zheng, Hao
    Chen, Yao
    Zhou, Chuanqing
    Chai, Xinyu
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2019, 27 (05) : 905 - 915