SEISMIC TEST RESULT (STATIC LOAD TEST) OF THE DYNAMIC FUNCTIONAL DEMAND VALVE FOR NUCLEAR POWER PLANT

被引:0
|
作者
Matsubara, Yoshinao [1 ]
Tsutsumi, Yoshitaka [2 ]
Watanabe, Urara [1 ]
Tanemura, Shota [3 ]
Takemoto, Yoshiaki [4 ]
机构
[1] Toshiba Energy Syst & Solut Corp, Yokohama, Kanagawa, Japan
[2] Chubu Elect Power Co Inc, Nagoya, Aichi, Japan
[3] Hitachi GE Nucl Energy Ltd, Hitachi, Ibaraki, Japan
[4] Mitsubishi Heavy Ind Co Ltd, Kobe, Hyogo, Japan
关键词
Seismic; Structural evaluation; Dynamic functional maintenance; Valve; Static load test; Validated operability acceleration;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The functional maintenance and confirmed acceleration of motor- and air-operated valves in nuclear power plants during an earthquake are regulated in the Japanese seismic design code (JEAC4601 (see Ref. [1])). In the present work, we used a resonant shaking table at the Central Research Institute of the Electric Power Industry (CRIEPI), which is capable of seismic tests at acceleration levels previously unachievable, in seismic tests carried out as high as 20x9.8 m/s(2) (see Ref. [2] to Ref. [8]). On the other hand, JEAC4601 requires the structural evaluation for the seismic critical parts with allowable stress of 1.5-times yield strength (1.5Sy). In this study, in order to confirm the adequacy of the allowable stress, a static load test equivalent to 1.5Sy and more was conducted for the representative valves, namely, the air-operated globe valve and the air-operated butterfly valve. As a result, we confirmed that the required function of the valves was satisfied.
引用
收藏
页数:5
相关论文
共 50 条
  • [11] Study on the Static and Dynamic Load Test of Ramp Bridge
    Zhao, Qingyun
    Wang, Lei
    Yu, Shihua
    Lu, Zhiqiang
    Sun, Yuelong
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT PROTECTION, PTS 1-3, 2013, 361-363 : 1101 - 1104
  • [12] Co-optimization of Dynamic/Static Test Power in Scan Test
    Wang Wei
    Han Yinhe
    Li Xiaowei
    Fang Fang
    CHINESE JOURNAL OF ELECTRONICS, 2009, 18 (01): : 54 - 58
  • [13] SELECTION OF THE TEST SPECIMENS FOR SEISMIC TESTS OF AIR -OPERATED VALVE ACTUATORS FOR NUCLEAR POWER PLANTS
    Kojima, Nobuo
    Tsutsumi, Yoshitaka
    Matsubara, Yoshinao
    Nishino, Koji
    Ito, Yasuyuki
    Kubota, Ryo
    Suzuki, Shigeki
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, 2019, VOL 8, 2019,
  • [14] Theoretical Seismic Analysis of Butterfly Valve for Nuclear Power Plant
    Han, Sang Uk
    Ahn, Jun Tae
    Lee, Kyung Chul
    Han, Seung Ho
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2012, 36 (09) : 1009 - 1015
  • [15] COMPLETE TEST AND ANALYSIS OF STATIC AND DYNAMIC POWER BEHAVIOR WITH ONE TEST INSTRUMENT
    不详
    ELECTRONICS WORLD, 2017, 123 (1969): : 10 - 11
  • [16] STATIC LOAD TEST ON DYNAMIC HIP SYSTEM (DHS) PLATES
    Freitas, Anderson
    de Mesquita, Alessandro Queiroz
    Daher, Walter Rodrigo
    de Macedo Souto, Diogo Ranier
    da Costa Rangel, Carlos Henrique
    ACTA ORTOPEDICA BRASILEIRA, 2009, 17 (04): : 215 - 218
  • [17] Study on the Static and Dynamic Load Test of Continuous Girder Bridge
    Yu, Shihua
    Zhang, Ting
    Zhao, Qingyun
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4, 2013, 405-408 : 1641 - 1644
  • [18] STATIC AND DYNAMIC LOAD TEST OF PRESTRESSED CONCRETE CONTINUOUS BRIDGE
    Zhan, Fa-Yi
    He, Guo-Jing
    Chen, Ai-Jun
    Yi, Jin
    4TH INTERNATIONAL SYMPOSIUM ON LIFETIME ENGINEERING OF CIVIL INFRASTRUCTURE, 2009, : 501 - 505
  • [20] Prediction Method of Static Load Test Results of Variable Section Bridge Based on Dynamic Load Test Data
    Lu P.-Z.
    Li D.-G.
    Shi Q.-T.
    Chen Y.-R.
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2022, 35 (08): : 213 - 221