Evaluation of the Transfemoral Bone-Implant Interface Properties Using Vibration Analysis

被引:1
|
作者
Mohamed, Mostafa [1 ]
Beaudry, Eric [1 ]
Shehata, Ahmed W. [1 ,2 ,3 ]
Raboud, Donald [1 ]
Hebert, Jacqueline S. [2 ,3 ,4 ]
Westover, Lindsey [1 ,2 ,3 ]
机构
[1] Univ Alberta, Fac Engn, Dept Mech Engn, Edmonton, AB, Canada
[2] Univ Alberta, Fac Med, Dept Biomed Engn, Edmonton, AB, Canada
[3] Univ Alberta, Fac Med & Dent, Edmonton, AB, Canada
[4] Univ Alberta, Fac Med & Dent, Dept Med, Edmonton, AB, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Advanced system for implant stability testing; Bone-anchored implants; Transfemoral amputation; Vibration analysis; FREQUENCY-ANALYSIS; OSSEOINTEGRATION; STABILITY; RECONSTRUCTION; REHABILITATION; AMPUTEES; SYSTEM;
D O I
10.1007/s10439-024-03561-6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Evaluating the bone-implant interface (BII) properties of osseointegrated transfemoral (TFA) implants is important for early failure detection and prescribing loads during rehabilitation. The objective of this work is to derive and validate a 1D finite element (FE) model of the Osseointegrated Prosthetic Limb (OPL) TFA system that can: (1) model its dynamic behaviour and (2) extract the BII properties. The model was validated by: (1) comparing the 1D FE formulation to the analytical and 3D FE solutions for a simplified cylinder, (2) comparing the vibration modes of the actual TFA geometry using 1D and 3D FE models, and (3) evaluating the BII properties for three extreme conditions (LOW, INTERMEDIATE, and HIGH) generated using 3D FE and experimental (where the implant was embedded, using different adhesives, in synthetic femurs) signals for additional validation. The modes predicted by the 1D FE model converged to the analytical and the 3D FE solutions for the cylinder. The 1D model also matched the 3D FE solution with a maximum frequency difference of 2.02% for the TFA geometry. Finally, the 1D model extracted the BII stiffness and the system's damping properties for the three conditions generated using the 3D FE simulations and the experimental INTERMEDIATE and HIGH signals. The agreement between the 1D FE and the 3D FE solutions for the TFA geometry indicates that the 1D model captures the system's dynamic behaviour. Distinguishing between the different BII conditions demonstrates the 1D model's potential use for the non-invasive clinical evaluation of the TFA BII properties.
引用
收藏
页码:2987 / 3008
页数:22
相关论文
共 50 条
  • [41] Ultrasonic Interferometric Procedure for Quantifying the Bone-Implant Interface
    Luetzelberger, Jan
    Arneth, Philipp
    Franck, Alexander
    Drese, Klaus Stefan
    SENSORS, 2023, 23 (13)
  • [42] Optimization of stress distribution of bone-implant interface (BII)
    Zhang, Chunyu
    Zeng, Chunyu
    Wang, Zhefu
    Zeng, Ting
    Wang, Yuehong
    BIOMATERIALS ADVANCES, 2023, 147
  • [43] A nonlinear homogenized finite element analysis of the primary stability of the bone-implant interface
    Ovesy, Marzieh
    Voumard, Benjamin
    Zysset, Philippe
    BIOMECHANICS AND MODELING IN MECHANOBIOLOGY, 2018, 17 (05) : 1471 - 1480
  • [44] Neutron microtomography to investigate the bone-implant interface-comparison with histological analysis
    Guillaume, Florian
    Le Cann, Sophie
    Tengattini, Alessandro
    Tornquist, Elin
    Falentin-Daudre, Celine
    Albini Lomami, Hugues
    Petit, Yvan
    Isaksson, Hanna
    Haiat, Guillaume
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (10):
  • [45] Analysis of bone-implant interaction phenomena by using a numerical approach
    Natali, AN
    Pavan, PG
    Ruggero, AL
    CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (01) : 67 - 74
  • [46] Evaluation of Bone-Implant Interface: Effects of Angiotensin II Receptor Blockade in Hypertensive Rats
    Mulinari-Santos, Gabriel
    dos Santos, Jaqueline Silva
    de Souza Batista, Fabio Roberto
    Pitol-Palin, Leticia
    da Silva, Ana Claudia Ervolino
    Botacin, Paulo Roberto
    Antoniali, Cristina
    Okamoto, Roberta
    COATINGS, 2025, 15 (01):
  • [47] Optical bone chambers as tools for studying the bone-implant interface: A review
    Winet, H
    CELLS AND MATERIALS, 1995, 5 (03): : 293 - 308
  • [48] Nanoscale characterization of bone-implant interface and biomechanical modulation of bone ingrowth
    Clark, Paul A.
    Clark, Andrew M.
    Rodriguez, Anthony
    Hussain, Mohammad A.
    Mao, Jeremy J.
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2007, 27 (03): : 382 - 393
  • [49] Mechanical properties of human bone-implant interface tissue in aseptically loose hip implants
    Kraaij, Gert
    Zadpoor, Amir A.
    Tuijthof, Gabrielle J. M.
    Dankelman, Jenny
    Nelissen, Rob G. H. H.
    Valstar, Edward R.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 38 : 59 - 68
  • [50] Microelastic properties of the bone-implant interface upon nanoindentation with atomic force microscopy.
    Clark, AM
    Sumner, DR
    Abdelhalim, TS
    Clark, PA
    Mao, JJ
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A473 - A473