Design and characterization of a hybrid PET detector with DOI capability

被引:0
|
作者
He, Wen [1 ,2 ]
Zhao, Yangyang [1 ]
Zeng, Honghao [1 ,3 ]
Huang, Wenjie [1 ]
Yang, Hang [1 ]
Zhao, Xin [1 ]
Wang, Qiang [4 ]
Wang, Lu [4 ]
Niu, Ming [1 ]
Zhang, Lei [2 ,5 ]
Ren, Qiushi [1 ,2 ]
Gu, Zheng [1 ,2 ]
机构
[1] Inst Biomed Engn, Shenzhen Bay Lab, Shenzhen, Peoples R China
[2] Peking Univ, Shenzhen Grad Sch, Shenzhen, Peoples R China
[3] Chinese Univ Hong Kong, Ciechanover Inst Precis & Regenerat Med, Sch Med, Shenzhen, Peoples R China
[4] 26th Inst China Elect Technol Grp Corp, Chongqing, Peoples R China
[5] Inst Canc Res, Shenzhen Bay Lab, Shenzhen, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
calibration; coincidence timing resolution (CTR); depth-of-interaction (DOI); positron emission tomography (PET); semi-monolithic; spatial resolution; QUASI-MONOLITHIC DETECTOR; ENDED READOUT; DEPTH; CALIBRATION;
D O I
10.1002/mp.17313
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundMonolithic or semi-monolithic detectors are attractive for positron emission tomography (PET) scanners with depth-of-interaction (DOI) capability. However, they often require complicated calibrations to determine the interaction positions of gamma photons.PurposeWe introduce a novel hybrid detector design that combines pixelated and semi-monolithic elements to achieve DOI capability while simplifying the calibrations for positioning.MethodsA prototype detector with eight hybrid lutetium-yttrium oxyorthosilicate (LYSO) layers having dimensions of 25.8 x 12.9 x 15 mm3 was constructed. The energy-weighted and energy-squared weighted averages were used for estimating the x- (pixelated direction) and y-positions (non-pixelated direction). Pseudo-pixels were defined as discrete areas on the flood image based on the crystal look-up table (LUT). The intrinsic spatial resolutions in the pixelated and non-pixelated directions were measured. The ratio of the maximum to the sum of the multipixel photon counter (MPPC) signals was used to estimate the DOI positions. The coincidence timing resolution (CTR) was measured using the average and energy-weighted average of the earliest n time stamps. Two energy windows of 250-700 and 400-600 keV were applied for the measurements.ResultsThe pattern of the flood images showed discrete event clusters, demonstrating that simple calibrations for determining the x- and y-positions of events could be achieved. Under 400-600 keV energy window, the average intrinsic spatial resolutions were 1.15 and 1.34 mm for the pixelated and non-pixelated directions; the average DOI resolution of the second row of pseudo-pixels was 5.1 mm in full width at half maximum (FWHM); when using the energy-weighted average of the earliest four-time stamps, the best CTR of 350 ps was achieved. Applying a broader energy window of 250-700 keV only slightly degrades the DOI resolution while maintaining the intrinsic resolution; the best CTR degrades to 410 ps.ConclusionsThe proposed hybrid detector concept was verified, and a prototype detector showed high performance for 3D positioning and timing resolution. The novel detector concept shows promise for preclinical and clinical PET scanners with DOI capability.
引用
收藏
页码:7140 / 7152
页数:13
相关论文
共 50 条
  • [21] Design of a High Performances Small Animal PET System With Axial Oriented Crystals and DOI Capability
    Salvador, Samuel
    Huss, Daniel
    Brasse, David
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (01) : 17 - 23
  • [22] A Low-Cost DOI Block Detector for PET
    Zhang, Yuxuan
    Baghaei, Hossain
    Yan, Han
    Wong, Wai-Hoi
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [23] Design and Characterization of a Gradient-Transparent RF Copper Shield for PET Detector Modules in Hybrid MR-PET Imaging
    Berneking, Arne
    Trinchero, Riccardo
    Ha, YongHyun
    Finster, Felix
    Cerello, Piergiorgio
    Lerche, Christoph
    Shah, Nadim Jon
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (05) : 1118 - 1127
  • [24] Design of High-Resolution Brain PET Using Dual-Layer DOI Detector
    Lim, W.
    Lee, S.
    Jung, J. H.
    Choi, Y.
    INTERNAL MEDICINE JOURNAL, 2022, 52 : 33 - 34
  • [25] Design of a preclinical PET DOI detector module according to the reflector application area of the scintillation pixels
    Seung-Jae Lee
    Cheol-Ha Baek
    Journal of the Korean Physical Society, 2021, 78 : 1236 - 1240
  • [26] Design of a preclinical PET DOI detector module according to the reflector application area of the scintillation pixels
    Lee, Seung-Jae
    Baek, Cheol-Ha
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2021, 78 (12) : 1236 - 1240
  • [27] Signal Transmission With Long Cable for Design of PET Detector for Hybrid PET-MRI
    Kim, Kyu Bom
    Choi, Yong
    Kang, Jihoon
    Jung, Jin Ho
    Hu, Wei
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (05) : 2010 - 2016
  • [28] Design Concepts and Characterization of a Next Generation Clinical PET Detector
    Cates, J. W.
    Levin, C. S.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [29] Highly Multiplexed DOI PET Detector Based on SiPM Sensors
    Chil, R.
    Konstantinou, G.
    Desco, M.
    Vaquero, J. J.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [30] Development of DOI Detector for PET using Different Kinds of Reflectors
    Lee, Seung-Jae
    Baek, Cheol-Ha
    JOURNAL OF MAGNETICS, 2020, 25 (04) : 670 - 673