Mechanical properties of steel fiber reinforced recycled concrete under compression-shear stress state

被引:0
|
作者
Chen, Yuliang [1 ,2 ,3 ]
He, Qin [1 ]
Jiang, Rui [1 ]
Ye, Peihuan [1 ,2 ]
机构
[1] Guangxi Univ Sci & Technol, Coll Civil Engn & Architecture, Liuzhou 545006, Peoples R China
[2] Key Lab Disaster Prevent & Mitigat & Prestress Tec, Liuzhou 545006, Peoples R China
[3] Guangxi Univ Sci & Technol, Guangxi Engn Res Ctr Safety Prevent & Control Asse, Liuzhou 545006, Peoples R China
来源
关键词
Recycled concrete; Steel fiber; Combined compression-shear; Shear strength composition; Shear toughness; AGGREGATE CONCRETE; STRAIN BEHAVIOR; STRENGTH;
D O I
10.1016/j.jobe.2024.109820
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The continuous urbanization of construction has led to an increasing demand for concrete, resulting in large-scale gravel and river sand mining, which seriously affect the sustainable development of the environment. The waste concrete produced by the demolition of old buildings is processed into recycled aggregate to replace natural aggregate, and then the preparation of recycled concrete can effectively alleviate this problem. This paper investigates the mechanical properties of steel fiber reinforced recycled concrete (SFRRAC) under compression shear conditions, a compression shear test with 99 cubic specimens was designed, with the variation parameters being recycled aggregate concrete replacement rate, compressive stress, and steel fiber content. The failure mode of SFRRAC under compression-shear stress was observed, and the shear force-displacement curve was calculated. Furthermore, a thorough examination was performed to assess the mechanical characteristics of SFRRAC specimens under compression-shear stress. The findings of this study suggest that as the compressive stress increases, the failure characteristics of the specimens shift from exhibiting brittle failure to displaying ductile failure. The shear strength is most sensitive to the change in compressive stress. When the compressive stress reaches 6 MPa, the shear strength can reach 3.41 times that of the direct shear specimen. The shear strength of SFRRAC specimens is composed of the bond strength of concrete, shear expansion strength, and friction shear strength. The incorporation of steel fibers can modify the distribution of shear strength among the individual components. The adverse effect of the recycled aggregate replacement rate on the toughness index of the specimen is mainly concentrated after the peak point. Nevertheless, an elevation in compressive stress and the inclusion of steel fibers can counterbalance this detrimental influence. The shear strength calculation formula of SFRRAC in shear state is put forward, which has a reference value. This study provides an experimental reference and a theoretical basis for further examination of SFRRAC.
引用
收藏
页数:19
相关论文
共 50 条
  • [11] Experiment on mechanical properties of steel fiber recycled aggregate concrete under triaxial compression
    Chen Y.
    Ji Y.
    Chen Z.
    Ye P.
    Wu H.
    Fuhe Cailiao Xuebao/Acta Materiae Compositae Sinica, 2022, 39 (08): : 4005 - 4016
  • [12] Stress state of steel plate shear walls under compression-shear combination load
    Lv, Yang
    Wu, Di
    Zhu, Yuhao
    Liang, Xiao
    Shi, Yanchao
    Yang, Zhen
    Li, Zhong-Xian
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2018, 27 (06):
  • [13] Mechanical Properties under Compression and Microscopy Analysis of Basalt Fiber Reinforced Recycled Aggregate Concrete
    Zhang, Xianggang
    Zhou, Gaoqiang
    Xu, Ping
    Fu, Lei
    Deng, Dapeng
    Kuang, Xiaomei
    Fan, Yuhui
    MATERIALS, 2023, 16 (06)
  • [14] Shear strength and failure criterion analysis of steel fiber reinforced concrete exposed to elevated temperature under combined compression-shear loading
    Yang, Haifeng
    Luo, Jinhai
    Yang, Qingmei
    Liu, Chengli
    MATERIALS AND STRUCTURES, 2024, 57 (04)
  • [15] Mechanical properties of concrete reinforced with corrugated steel fiber under uniaxial compression and tension
    Ran, Jinlin
    Li, Tingchun
    Chen, Dianhao
    Shang, Liming
    Li, Weiteng
    Zhu, Qingwen
    STRUCTURES, 2021, 34 : 1890 - 1902
  • [16] Shear strength and failure criterion of carbon fiber reinforced coral concrete under combined compression-shear stresses
    Liu, Bing
    Ye, Junpeng
    Liu, Xiaoyan
    Lin, Weixin
    Deng, Zhiheng
    Liu, Qizhou
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 325
  • [17] Mechanical Properties of Hybrid Fiber Recycled Concrete under Cyclic Compression
    Chen, Yuliang
    Wang, Qi
    Liang, Xin
    Ye, Peihuan
    Li, Hong
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2023, 21 (07) : 555 - 572
  • [18] Mechanical properties and damage constitutive of recycled aggregate concrete with polyvinyl alcohol fiber under compression and shear
    Chen, Yuliang
    Zhang, Shaosong
    Ye, Peihuan
    Liang, Xin
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2022, 17
  • [19] Mechanical Properties of Fully Recycled Aggregate Concrete Reinforced with Steel Fiber and Polypropylene Fiber
    Zhang, Lijuan
    Li, Xiang
    Li, Changbin
    Zhao, Jun
    Cheng, Shengzhao
    MATERIALS, 2024, 17 (05)
  • [20] Mechanical properties and damage constitutive model of basalt fibre-reinforced coral concrete under compression-shear loading
    Zhou, Youwei
    Xiao, Jianzhuang
    Deng, Zhiheng
    Yang, Haifeng
    Jiang, Jiasheng
    Wei, Tingcong
    JOURNAL OF BUILDING ENGINEERING, 2024, 98