Protocol of a randomised controlled trial of real-time continuous glucose monitoring in neonatal intensive care 'REACT'

被引:12
|
作者
Beardsall, Kathryn [1 ,2 ]
Thomson, Lynn [1 ,2 ]
Guy, Catherine [1 ]
van Weissenbruch, Mirjam M. [3 ]
Iglesias, Isabel [4 ]
Muthukumar, Priya [5 ]
Somisetty, Sateesh Kumar [6 ]
Bond, Simon [7 ]
Petrou, Stavros [8 ]
Dunger, David [1 ]
机构
[1] Univ Cambridge, Dept Paediat, Cambridge, England
[2] Cambridge Univ Hosp NHS Fdn Trust, Dept Paediat & Neonatol, Cambridge, England
[3] Vrije Univ Amsterdam Med Ctr, Dept Paediat, Amsterdam, Netherlands
[4] St Joan de Deu, Dept Paediat, Barcelona, Catalunya, Spain
[5] Norfolk & Norwich Univ Hosp NHS Fdn Trust, Dept Paediat, Norwich, Norfolk, England
[6] Luton & Dunstable Univ Hosp, Dept Paediat, Luton, Beds, England
[7] Cambridge Univ Hosp NHS Fdn Trust, Cambridge Clin Trials Unit, Cambridge, England
[8] Univ Warwick, Warwick Med Sch, Div Hlth Sci, Coventry, W Midlands, England
来源
BMJ OPEN | 2018年 / 8卷 / 06期
关键词
INSULIN THERAPY; RISK-FACTOR; HYPERGLYCEMIA; DEATH;
D O I
10.1136/bmjopen-2017-020816
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Hyperglycaemia is common in the very preterm infant and has been associated with adverse outcomes. Preventing hyperglycaemia without increasing the risk of hypoglycaemia has proved challenging. The development of real-time continuous glucose monitors (CGM) to inform treatment decisions provides an opportunity to reduce this risk. This study aims to assess the feasibility of CGM combined with a specifically designed paper guideline to target glucose control in the preterm infant. Methods and analyses The Real Time Continuous Glucose Monitoring in Neonatal Intensive Care (REACT) trial is an international multicentre randomised controlled trial. 200 preterm infants <= 1200 g and <= 24 hours of age will be randomly allocated to either real-time CGM or standard care (with blinded CGM data collection). The primary outcome is time in target 2.6-10 mmol/L during the study intervention assessed using CGM. Secondary outcomes include efficacy relating to glucose control, utility including staff acceptability, safety outcomes relating to incidence and prevalence of hypoglycaemia and health economic analyses. Ethics and dissemination The REACT trial has been approved by the National Health Service Health Research Authority National Research Ethics Service Committee East of England (Cambridge Central); Medical Ethics Review Committee, VU University Medical Centre, Amsterdam, The Netherlands and the Research Ethics Committee, Sant Joan de Deu Research Foundation, Barcelona, Spain. Recruitment began in July 2016 and will continue until mid-2018. The trial has been adopted by the National Institute of Health Research Clinical Research Network portfolio (ID: 18826) and is registered with anInternational Standard Randomised Control Number (ISRCTN registry ID: 12793535). Dissemination plans include presentations at scientific conferences, scientific publications and efforts at stakeholder engagement.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Efficacy and safety of real-time continuous glucose monitoring guiding insulin administration in the hospital: a randomised clinical trial
    Umpierrez, G. E.
    Galindo, R. J.
    Urrutia, M. A.
    Vellanki, P.
    Migdal, A. L.
    Davis, G. M.
    Pasquel, F. J.
    Fayfman, M.
    Idrees, T.
    Peng, L.
    Singh, L. G.
    Spanakis, E. K.
    DIABETOLOGIA, 2022, 65 (SUPPL 1) : S53 - S53
  • [22] Real-time continuous glucose monitoring in the ICU
    J Gios
    B Manuel-y-Keenoy
    P Rogiers
    Critical Care, 19 (Suppl 1):
  • [23] Accuracy and Reliability of Real-Time Continuous Glucose Monitoring in the Intensive Care Unit after Major Abdominal Surgery
    Hagerf , Barbora
    Protus, Marek
    Nemetova, Lenka
    Mraz, Milos
    Haluzik, Martin
    Girman, Peter
    Franekova, Janka
    Svirlochova, Veronika
    Jabor, Antonin
    DIABETES, 2023, 72
  • [24] Real-time, evidence-based medicine instruction: a randomized controlled trial in a neonatal intensive care unit
    Bradley, DR
    Rana, GK
    Martin, PW
    Schumacher, RE
    JOURNAL OF THE MEDICAL LIBRARY ASSOCIATION, 2002, 90 (02) : 194 - 201
  • [25] A Feasibility Study to Detect Neonatal Hypoglycemia Using Real-Time Continuous Glucose Monitoring
    Nally, Laura M.
    Bondy, Nicholas W.
    Doiev, Jasmine
    Buckingham, Bruce
    Wilson, Darrell
    DIABETES, 2018, 67
  • [26] Open-Source Technology for Real-Time Continuous Glucose Monitoring in the Neonatal Intensive Care Unit: Case Study in a Neonate With Transient Congenital Hyperinsulinism
    Braune, Katarina
    Waeldchen, Mandy
    Raile, Klemens
    Hahn, Sigrid
    Ubben, Tebbe
    Roemer, Susanne
    Hoeber, Daniela
    Reibel, Nora Johanna
    Launspach, Michael
    Blankenstein, Oliver
    Buehrer, Christoph
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2020, 22 (12)
  • [27] The use of real-time continuous glucose monitoring to correct hypoglycaemia unawareness in adolescents: initial data from a randomised trial
    Ly, Trang T.
    Hewitt, Jacqueline
    Kendall, Julie A.
    Davis, Elizabeth A.
    Jones, Timothy W.
    HORMONE RESEARCH, 2009, 72 : 51 - 51
  • [28] Practical Aspects of Real-Time Continuous Glucose Monitoring
    Gilliam, Lisa K.
    Hirsch, Irl B.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 : S75 - S82
  • [29] Real-Time Continuous Glucose Monitoring in Preterm Infants
    Joseph, Rachel
    Rosa, Jenna Hope-Altomari
    NEONATAL NETWORK, 2022, 41 (06): : 376 - 376
  • [30] Reliability of real-time continuous glucose monitoring in infants
    Tomotaki, Seiichi
    Toyoshima, Katsuaki
    Shimokaze, Tomoyuki
    Kawai, Masahiko
    PEDIATRICS INTERNATIONAL, 2019, 61 (10) : 1001 - 1006