Feasibility of 2-Point Fixation by Absorbable Plates Using the Transoral Approach in Management of the Zygomatic Complex Fractures

被引:0
|
作者
Diarra, Drissa [1 ,2 ,3 ,4 ,5 ]
Zhang, Ze-Xing [1 ,2 ,3 ,4 ,5 ]
Wang, Hang [1 ,2 ,3 ,4 ,5 ]
Li, Zhi [1 ,2 ,3 ,4 ,5 ]
机构
[1] Wuhan Univ, State Key Lab Oral & Maxillofacial Reconstruct & R, Wuhan, Peoples R China
[2] Wuhan Univ, Key Lab Oral Biomed, Minist Educ, Wuhan, Peoples R China
[3] Wuhan Univ, Hubei Key Lab Stomatol, Wuhan, Peoples R China
[4] Wuhan Univ, Sch & Hosp Stomatol, Wuhan, Peoples R China
[5] Wuhan Univ, Sch & Hosp Stomatol, Dept Oral & Maxillofacial Surg, 237 Luoyu Rd, Wuhan 430079, Peoples R China
关键词
Absorbable plate; stability; transoral approach; two-point fixation; zygomatic complex fractures; TRIPOD FRACTURES; 1-POINT FIXATION;
D O I
10.1097/SCS.0000000000010158
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose:The purpose of this study was to retrospectively evaluate the feasibility of 2-point fixation using absorbable plates by the transoral approach in the management of the zygomatic complex (ZMC) fractures. Methods:Twenty-five patients (15 male and 10 female, age range 16 y to 55 y) with Knight and North Group III zygomatic fractures were included in this case series. Open reduction by intraoral approach was performed on these patients, and the fractures were fixed using absorbable plates placed at the zygomaticomaxillary buttress and infraorbital rim. Postoperatively, follow-up was undertaken to evaluate the fracture healing, mouth opening, facial asymmetry, diplopia, and paresthesia. Results:Postoperatively, all patients achieved uneventful healing; facial symmetry and wound healing were achieved, along with sensory recovery involving the infraorbital nerve. Complications such as sensory disturbances, infection, diplopia, malunion, and nonunion were not encountered in these patients. Conclusions:Two-point fixation using absorbable plates by transoral approach can provide sufficient stabilization for Knight and North Group III zygomatic fractures.
引用
收藏
页码:e442 / e444
页数:3
相关论文
共 50 条
  • [41] Complex AO type C3 distal femur fractures: Results after fixation with a lateral locked plate using modified swashbuckler approach
    Anuj Agrawal
    Vivek Kiyawat
    Indian Journal of Orthopaedics, 2017, 51 : 18 - 27
  • [42] SURGERY OF ACETABULUM USING 2 SURGICAL TEAMS - POSSIBILITY OF A SIMILAR APPROACH TO BOTH PARTS OF ACETABULUM IN COMPLEX FRACTURES
    GOSSET, J
    APOIL, A
    ANNALES DE CHIRURGIE, 1975, 29 (12): : 1083 - 1085
  • [43] Minimally invasive surgery for intra-articular calcaneus fractures: a 9-year, single-center, retrospective study of a standardized technique using a 2-point distractor
    Rodemund, Christian
    Krenn, Ronny
    Kihm, Carl
    Leister, Iris
    Ortmaier, Reinhold
    Litzlbauer, Werner
    Schwarz, Angelika M.
    Mattiassich, Georg
    BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
  • [44] Minimally invasive surgery for intra-articular calcaneus fractures: a 9-year, single-center, retrospective study of a standardized technique using a 2-point distractor
    Christian Rodemund
    Ronny Krenn
    Carl Kihm
    Iris Leister
    Reinhold Ortmaier
    Werner Litzlbauer
    Angelika M. Schwarz
    Georg Mattiassich
    BMC Musculoskeletal Disorders, 21
  • [45] Anterior management of C2 fractures using miniplate fixation: outcome, function and quality of life in a case series of 15 patients
    Franke, Axel
    Bieler, Dan
    Wern, Rebecca
    Trotzke, Tim
    Hentsch, Sebastian
    Kollig, Erwin
    EUROPEAN SPINE JOURNAL, 2018, 27 (06) : 1332 - 1341
  • [46] Anterior management of C2 fractures using miniplate fixation: outcome, function and quality of life in a case series of 15 patients
    Axel Franke
    Dan Bieler
    Rebecca Wern
    Tim Trotzke
    Sebastian Hentsch
    Erwin Kollig
    European Spine Journal, 2018, 27 : 1332 - 1341
  • [47] Accuracy of 4 Free Online Dosing Calculators in Predicting the Vancomycin Area Under the Concentration-Time Curve Calculated Using a 2-Point Pharmacokinetic Approach
    Belz, Sarah N.
    Seabury, Robert W.
    Steele, Jeffrey M.
    Darko, William
    Miller, Christopher D.
    Probst, Luke A.
    Kufel, Wesley D.
    ANNALS OF PHARMACOTHERAPY, 2023, 57 (04) : 432 - 440
  • [48] Reconstruction of Severe Medial Orbital Wall Fractures Using Titanium Mesh Plates Placed Using Transcaruncular-Transconjunctival Approach: A Successful Combination of 2 Techniques
    Scolozzi, Paolo
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 69 (05) : 1415 - 1420
  • [49] Internal Fixation of 4-Part Proximal Humerus Fractures and Fracture Dislocations Using Extended Deltoid-splitting Approach, Locking Plates, and Calcium Sulfate Graft: Technical Details
    Zadeh, Hamid G.
    Somasundaram, Karthikeyan
    Babu, Victor
    Movahedi, Roya
    TECHNIQUES IN SHOULDER AND ELBOW SURGERY, 2018, 19 (03): : 129 - 137
  • [50] Complications and morbidity of the extended delto-pectoral approach in treating complex humeral shaft fractures with proximal metaphyseal extension using a long locking plate for internal fixation
    Rechsteiner, Jan
    Grieb, Maximilian
    Zdravkovic, Vilijam
    Spross, Christian
    Jost, Bernhard
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)