Timing-Driven High-Level Synthesis for Continuous-Flow Microfluidic Biochips

被引:0
|
作者
Ye, Zhengyang [1 ,2 ,3 ]
Chen, Zhisheng [4 ]
Pan, Youlin [1 ,2 ,3 ]
Liu, Genggeng [1 ,2 ,3 ]
Guo, Wenzhong [1 ,2 ,3 ]
Ho, Tsung-Yi [5 ]
Huang, Xing [6 ]
机构
[1] Fuzhou Univ, Coll Comp & Data Sci, Fuzhou, Peoples R China
[2] Minist Educ, Engn Res Ctr Big Data Intelligence, Fuzhou, Peoples R China
[3] Fuzhou Univ, Fujian Key Lab Network Comp & Intelligent Informa, Fuzhou, Peoples R China
[4] Xiamen Univ, Sch Informat, Xiamen, Peoples R China
[5] Chinese Univ Hong Kong, Dept Comp Sci & Engn, Hong Kong, Peoples R China
[6] Northwestern Polytech Univ, Sch Comp Sci, Xian, Peoples R China
基金
中国国家自然科学基金;
关键词
continuous-flow microfluidic biochips; high-level synthesis; time constraints;
D O I
10.1109/ISQED60706.2024.10528370
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
As continuous-flow microfluidic biochips technology rapidly advances, its automated synthesis methods require adapting to increasingly complex and stringent biochemical applications. In particular, with the introduction of time-sensitive bioassays, in this work, we present a timing-driven high-level synthesis method to optimize the resource efficiency of bioassays considering the time constraints. Specifically, we investigate the existing forms of time constraints and propose a corresponding flexible modeling approach based on reaction-control which can achieve downward compatibility for physical design. Additionally, we also analyze the impact of storage and wash on time constraints. The experimental results show that our method achieves efficient execution and low devices cost while satisfying time constraints.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] FACTOR OF DILUTION WITH FRESHLY PUMPED LEACHANT IN CONTINUOUS-FLOW LEACH TESTS ON HIGH-LEVEL WASTE GLASS
    KAMIZONO, H
    SAGAWA, T
    TASHIRO, S
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1989, 26 (08) : 811 - 813
  • [42] CONTINUOUS-FLOW LEACH TESTS OF SIMULATED HIGH-LEVEL WASTE GLASS IN SYNTHESIZED GROUNDWATER AND DEIONIZED WATER
    KAMIZONO, H
    SHIMIZU, I
    BANBA, T
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1987, 24 (04) : 308 - 314
  • [43] Timing variation-aware high-level synthesis
    Jong, Jongyoon
    Kim, Taewhan
    IEEE/ACM INTERNATIONAL CONFERENCE ON COMPUTER-AIDED DESIGN DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2007, : 424 - 428
  • [44] A continuous-flow, microfluidic fraction collection device
    Baker, Christopher A.
    Roper, Michael G.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (28) : 4743 - 4748
  • [45] Streaming dielectrophoresis for continuous-flow microfluidic devices
    Cummings, EB
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2003, 22 (06): : 75 - 84
  • [46] Three-Stage Rapid Physical Design Algorithm for Continuous-Flow Microfluidic Biochips Considering Actual Fluid Manipulations
    Liu, Genggeng
    Liu, Yufan
    Pan, Youlin
    Chen, Zhen
    ELECTRONICS, 2024, 13 (02)
  • [47] A timing-driven module-based chip design flow
    Mo, F
    Brayton, RK
    41ST DESIGN AUTOMATION CONFERENCE, PROCEEDINGS 2004, 2004, : 67 - 70
  • [48] ELECTRONIC TIMING OF A HIGH-SPEED IMMUNONEPHELOMETRIC CONTINUOUS-FLOW SYSTEM
    LIZANA, J
    JANSSON, L
    HELLSING, K
    CLINICAL CHEMISTRY, 1975, 21 (06) : 762 - 765
  • [49] A microfluidic reactor application for the continuous-flow photocatalytic selective synthesis of aromatic aldehydes
    Lima, Maria J.
    Silva, Adrián M.T.
    Silva, Cláudia G.
    Faria, Joaquim L.
    Applied Catalysis A: General, 2020, 608
  • [50] Continuous-Flow Biochips: Technology, Physical-Design Methods, and Testing
    Pop, Paul
    Araci, Ismail Emre
    Chakrabarty, Krishnendu
    IEEE DESIGN & TEST, 2015, 32 (06) : 8 - 19