Differentiating Low-Grade from High-Grade Intracranial Ependymomas: Comparison of Dynamic Contrast-Enhanced MRI and Diffusion-Weighted Imaging

被引:0
|
作者
Arevalo-Perez, Julio [1 ]
Yllera-Contreras, Elena [1 ]
Peck, Kyung K. [2 ]
Hatzoglou, Vaios [1 ]
Yildirim, Onur [1 ]
Rosenblum, Marc K. [3 ]
Holodny, Andrei I. [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Radiol, 1275 York Ave, New York, NY 10065 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY USA
[3] Mem Sloan Kettering Canc Ctr, Dept Pathol, New York, NY 10021 USA
关键词
CEREBRAL BLOOD-VOLUME; TUMOR GRADE; PERFUSION MRI; MAPS; COEFFICIENT; PARAMETERS; GLIOMAS; T1;
D O I
10.3174/ajnr.A8226
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The aim of this study was to determine the diagnostic value of fractional plasma volume derived from dynamic contrast-enhanced perfusion MR imaging versus ADC, obtained from DWI in differentiating between grade 2 (low-grade) and grade 3 (high-grade) intracranial ependymomas. MATERIALS AND METHODS: A hospital database was created for the period from January 2013 through June 2022, including patients with histologically-proved ependymoma diagnosis with available dynamic contrast-enhanced MR imaging. Both dynamic contrast-enhanced perfusion and DWI were performed on each patient using 1.5T and 3T scanners. Fractional plasma volume maps and ADC maps were calculated. ROIs were defined by a senior neuroradiologist manually by including the enhancing tumor on every section and conforming a VOI to obtain the maximum value of fractional plasma volume (Vp(max)) and the minimum value of ADC (ADC(min)). A Mann-Whitney U test at a significance level of corrected P = .01 was used to evaluate the differences. Additionally, receiver operating characteristic curve analysis was applied to assess the sensitivity and specificity of Vp(max) and ADC(min) values. RESULTS: A total of 20 patients with ependymomas (10 grade 2 tumors and 10 grade 3 tumors) were included. Vp(max) values for grade 3 ependymomas were significantly higher (P < .002) than those for grade 2. ADC(min) values were overall lower in high-grade lesions. However, no statistically significant differences were found (P = .12114). CONCLUSIONS: As a dynamic contrast-enhanced perfusion MR imaging metric, fractional plasma volume can be used as an indicator to differentiate grade 2 and grade 3 ependymomas. Dynamic contrast-enhanced perfusion MR imaging plays an important role with high diagnostic value in differentiating low- and high-grade ependymoma.
引用
收藏
页码:927 / 933
页数:7
相关论文
共 50 条
  • [41] Whole-body MRI, dynamic contrast-enhanced MRI, and diffusion-weighted imaging for the staging of multiple myeloma
    Dutoit, Julie C.
    Verstraete, Koenraad L.
    SKELETAL RADIOLOGY, 2017, 46 (06) : 733 - 750
  • [42] Whole-body MRI, dynamic contrast-enhanced MRI, and diffusion-weighted imaging for the staging of multiple myeloma
    Julie C. Dutoit
    Koenraad L. Verstraete
    Skeletal Radiology, 2017, 46 : 733 - 750
  • [43] Prostate Cancer Detection With 3 T MRI: Comparison of Diffusion-Weighted Imaging and Dynamic Contrast-Enhanced MRI in Combination With T2-Weighted Imaging
    Kitajima, Kazuhiro
    Kaji, Yasushi
    Fukabori, Yoshitatsu
    Yoshida, Ken-ichiro
    Suganuma, Narufumi
    Sugimura, Kazuro
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) : 625 - 631
  • [44] An Assessment of Diffusion-Weighted Imaging and Contrast-Enhanced MRI in the Diagnosis of Cholesteatoma Recurrence
    Kavanagh, R. G.
    Carroll, A. G.
    Hone, S. W.
    Malone, D. E.
    Killeen, R. P.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2016, 185 : S524 - S525
  • [45] CHARACTERIZATION OF RECURRENT LOW-GRADE GLIOMAS USING DIFFUSION-WEIGHTED MR IMAGING
    Cloyd, Colleen
    Chang, Susan
    Cha, Soonmee
    Berger, Mitchel S.
    McDermott, Michael William
    Parsa, Andrew T.
    Aghi, Manish Kumar
    Nelson, Sarah J.
    NEURO-ONCOLOGY, 2009, 11 (05) : 674 - 675
  • [46] The utility of diffusion MRI with quantitative ADC measurements for differentiating high-grade from low-grade cerebral gliomas: Evidence from a meta-analysis
    Zhang, Li
    Min, Zhiqian
    Tang, Min
    Chen, Sipan
    Lei, Xiaoyan
    Zhang, Xiaoling
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2017, 373 : 9 - 15
  • [47] Comparative study between dynamic susceptibility contrast magnetic resonance imaging and arterial spin labelling perfusion in differentiating low-grade from high-grade brain tumours
    Patil, Vaibhav
    Malik, Rajesh
    Sarawagi, Radha
    POLISH JOURNAL OF RADIOLOGY, 2023, 88 : E521 - E528
  • [48] Multiparametric MRI model with dynamic contrast-enhanced and diffusion-weighted imaging enables breast cancer diagnosis with high accuracy
    Zhang, Michelle
    Horvat, Joao V.
    Bernard-Davila, Blanca
    Marino, Maria Adele
    Leithner, Doris
    Ochoa-Albiztegui, R. Elena
    Helbich, Thomas H.
    Morris, Elizabeth A.
    Thakur, Sunitha
    Pinker, Katja
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (03) : 864 - 874
  • [49] Dynamic contrast-enhanced MRI may be helpful to predict response and prognosis after bevacizumab treatment in patients with recurrent high-grade glioma: comparison with diffusion tensor and dynamic susceptibility contrast imaging
    Park, Yae Won
    Ahn, Sung Soo
    Moon, Ju Hyung
    Kim, Eui Hyun
    Kang, Seok-Gu
    Chang, Jong Hee
    Kim, Se Hoon
    Lee, Seung-Koo
    NEURORADIOLOGY, 2021, 63 (11) : 1811 - 1822
  • [50] Dynamic contrast-enhanced MRI may be helpful to predict response and prognosis after bevacizumab treatment in patients with recurrent high-grade glioma: comparison with diffusion tensor and dynamic susceptibility contrast imaging
    Yae Won Park
    Sung Soo Ahn
    Ju Hyung Moon
    Eui Hyun Kim
    Seok-Gu Kang
    Jong Hee Chang
    Se Hoon Kim
    Seung-Koo Lee
    Neuroradiology, 2021, 63 : 1811 - 1822