Three-dimensional study of microchannel with elliptical rib

被引:0
|
作者
Raj, Deepak Kumar [1 ]
Datta, Aparesh [1 ]
机构
[1] Natl Inst Technol Durgapur, Dept Mech Engn, Durgapur 713209, West Bengal, India
关键词
SHAPED REENTRANT CAVITIES; HEAT-TRANSFER; SINK; ENHANCEMENT;
D O I
10.1063/5.0217857
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Flow past objects in the microchannel are used to disturb the flow and thereby achieve adequate mixing. A three-dimensional numerical investigation has been carried out to analyze the flow characteristics around an elliptical rib with various aspect ratios (AR) ranging from 0.4 to 0.6, where the major axis was aligned parallel to the free stream. The study encompassed Reynolds numbers (Re) ranging from 18 to 202, calculated based on a hydraulic diameter of 184.61 mu m. The fluid flow equation has been solved using the control volume method in ANSYS FLUENT software, under the assumptions of steady, incompressible, and laminar flow around the elliptical rib. The elliptical ribs are placed symmetrically about the vertical mid-plane in a rectangular microchannel. Main characteristics, such as bubble length, separation angle, maximum vorticity, and skin friction coefficient on the ellipse surface, were obtained with and without heat flux using water as the working fluid. The impact of blockage on the steady flow properties was investigated by varying the AR of the elliptical rib. Change in AR causes the variation of 4.42% observed in the Nusselt number (Nu). It has been found that a pair of steady vortices starts to form at lower Re for higher AR. The bubble length and separation angle form early with heat flux compared to the without heat flux. The skin friction coefficient significantly drops the channel with heat flux compared to without heat flux. Considering the third direction along the height of the elliptical rib in the microchannel, the deviation in the bubble length and separation angle is 12.23% and 45.35%, respectively, at AR of 0.6, when heat flux is applied to the bottom wall.
引用
收藏
页数:14
相关论文
共 50 条
  • [32] Three-dimensional elliptical reconstruction for stereoscopic magnetic resonance angiography
    Liao, Jan-Ray
    Kuo, Shye-Chorng
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2012, 36 (04) : 271 - 280
  • [33] Three-dimensional analysis of elliptical inclusions in two-dimensional decagonal quasicrystal
    Li, Xin Pei
    Li, Lian He
    PHYSICA B-CONDENSED MATTER, 2022, 646
  • [34] A three-dimensional model for flow pumping in a microchannel inspired by insect respiration
    Yasser Aboelkassem
    Anne E. Staples
    Acta Mechanica, 2014, 225 : 493 - 507
  • [35] Three-dimensional effect of the Boston brace on the thoracic spine and rib cage
    Labelle, H
    Dansereau, J
    Bellefleur, C
    Poitras, B
    SPINE, 1996, 21 (01) : 59 - 64
  • [36] Three-dimensional roughness effect on microchannel heat transfer and pressure drop
    Croce, Giulio
    D'agaro, Paola
    Nonino, Carlo
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (25-26) : 5249 - 5259
  • [37] A three-dimensional model for flow pumping in a microchannel inspired by insect respiration
    Aboelkassem, Yasser
    Staples, Anne E.
    ACTA MECHANICA, 2014, 225 (02) : 493 - 507
  • [38] Three-Dimensional CFD Model of Pressure Drop in μTAS Devices in a Microchannel
    Agonafer, Damena D.
    Yeom, J.
    Shannon, M. A.
    JOURNAL OF ELECTRONIC PACKAGING, 2011, 133 (03)
  • [39] Simulation of laminar flow behavior in a microchannel and its three-dimensional visualization
    Yamaguchi, Y
    Takagi, F
    Yamashita, K
    Shimizu, H
    Maeda, H
    Sotowa, KI
    Kusakabe, K
    Yamasaki, Y
    Morooka, S
    KAGAKU KOGAKU RONBUNSHU, 2004, 30 (03) : 341 - 345
  • [40] Three-Dimensional Analysis of Liquid Propagation at Microchannel Junction using ESEM
    Yagi, Natsumi
    Kawai, Akira
    JOURNAL OF PHOTOPOLYMER SCIENCE AND TECHNOLOGY, 2017, 30 (06) : 709 - 714