Surface guided radiation therapy: An international survey on current clinical practice

被引:27
|
作者
Batista, V. [1 ,2 ,16 ]
Gober, M. [3 ,4 ]
Moura, F. [5 ]
Webster, A. [6 ]
Oellers, M. [7 ]
Ramtohul, M. [8 ]
Kuegele, M. [9 ]
Freislederer, P. [10 ]
Buschmann, M. [3 ]
Anastasi, G. [11 ]
Steiner, E. [4 ]
Al-Hallaq, H. [12 ]
Lehmann, J. [13 ,14 ,15 ]
机构
[1] Heidelberg Univ Hosp, Dept Radiat Oncol, Heidelberg, Germany
[2] Natl Ctr Radiat Oncol NCRO, Heidelberg Inst Radiat Oncol HIRO, Heidelberg, Germany
[3] Med Univ Vienna, Dept Radiat Oncol, Vienna, Austria
[4] Landesklinikum Wiener Neustadt, Inst Radiat Oncol & Radiotherapy, Wiener Neustadt, Austria
[5] Hosp CUF Descobertas, Dept Radiat Oncol, Lisbon, Portugal
[6] Univ Coll Hosp, Radiotherapy & Proton Beam Therapy, London, England
[7] MAASTRO Clin, Dept Med Phys, Maastricht, Netherlands
[8] Univ Hosp Birmingham, Queen Elizabeth Hosp, Dept Med Phys, Birmingham, England
[9] Skane Univ Hosp, Dept Haematol Oncol & Radiat Phys, Lund, Sweden
[10] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Radiat Oncol, Munich, Germany
[11] St Lukes Canc Ctr, Royal Surrey Fdn Trust, Radiotherapy Phys, Guildford, England
[12] Univ Chicago, Dept Radiat & Cellular Oncol, Chicago, IL USA
[13] Calvary Mater Newcastle, Radiat Oncol Dept, Waratah, Australia
[14] Univ Newcastle, Sch Informat & Phys Sci, Callaghan, Australia
[15] Univ Sydney, Inst Med Phys, Sydney, Australia
[16] Heidelberg Univ Hosp, Im Neuenheimer Feld 400, D-69120 Heidelberg, Germany
关键词
Survey; SGRT; Clinical practices; Surface; -guided; Motion management; WHOLE-BREAST RADIOTHERAPY; PATIENT SETUP; LOCALIZATION;
D O I
10.1016/j.tipsro.2022.03.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Surface Guided Radiation Therapy (SGRT) is being increasingly implemented into clinical practice across a number of techniques and irradiation-sites. This technology, which is provided by different vendors, can be used with most simulation- and delivery-systems. However, limited guidelines and the complexity of clinical settings have led to diverse patterns of operation. With the aim to understand current clinical practice a survey was designed focusing on specifics of the clinical implementation and usage. Materials and methods: A 32-question survey covered: type and number of systems, quality assurance (QA), clinical workflows, and identification of strengths/limitations. Respondents from different professional groups and countries were invited to participate. The survey was distributed internationally via ESTRO-membership, social media and vendors. Results: Of the 278 institutions responding, 172 had at least one SGRT-system and 136 use SGRT clinically. Implementation and QA were primarily based on the vendors' recommendations and phantoms. SGRT was mainly implemented in breast RT (116/136), with strong but diverse representation of other sites. Many (58/ 135) reported at least partial elimination of skin-marks and a third (43/126) used open-masks. The most common imaging protocol reported included the combination of radiographic imaging with SGRT. Patient positioning (115/136), motion management (104/136) and DIBH (99/136) were the main applications. Main barriers to broader application were cost, system integration issues and lack of demonstrated clinical value. A lack of guidelines in terms of QA of the system was highlighted. Conclusions: This overview of the SGRT status has the potential to support users, vendors and organisations in the development of practices, products and guidelines.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [41] Correction to: Recent advances in Surface Guided Radiation Therapy
    P. Freislederer
    M. Kügele
    M. Öllers
    A. Swinnen
    T.-O. Sauer
    C. Bert
    D. Giantsoudi
    S. Corradini
    V. Batista
    Radiation Oncology, 15
  • [42] Image-Guided Radiotherapy in Paediatrics: A Survey of International Patterns of Practice
    Wall, Verna
    Marignol, Laure
    ElBeltagi, Nazmy
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2018, 49 (03) : 265 - 269
  • [43] Survey of image-guided radiation therapy use in Australia
    Batumalai, V.
    Holloway, L.
    Kumar, S.
    Dundas, K.
    Jameson, M.
    Vinod, S.
    Delaney, G.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S492 - S493
  • [44] Image-guided radiation therapy: From concept to practice
    Jaffray, David A.
    SEMINARS IN RADIATION ONCOLOGY, 2007, 17 (04) : 243 - 244
  • [45] Technical note: Clinical evaluation of a newly released surface-guided radiation therapy system on DIBH for left breast radiation therapy
    Zhao, Hui
    Sarkar, Vikren
    Paxton, Adam
    Huang, Y. Jessica
    Haacke, Christine
    Price, Ryan G.
    Su, Fan-Chi Frances
    Szegedi, Martin
    Rassiah, Prema
    Salter, Bill
    MEDICAL PHYSICS, 2023, 50 (10) : 5978 - 5986
  • [46] The value of the physical examination in clinical practice: an international survey
    Elder, Andrew T.
    McManus, I. Chris
    Patrick, Alan
    Nair, Kichu
    Vaughan, Louella
    Dacre, Jane
    CLINICAL MEDICINE, 2017, 17 (06) : 490 - 498
  • [47] Aphasia outcome measurement in clinical practice: An international survey
    Tyler, Chloe
    Finch, Emma
    Shrubsole, Kirstine
    Ryan, Brooke
    Soroli, Efstathia
    Martinez-Ferreiro, Silvia
    Wallace, Sarah J.
    APHASIOLOGY, 2023, 37 (10) : 1576 - 1593
  • [48] Implementation and obstacles of pharmacogenetics in clinical practice: An international survey
    Abou Diwan, Elizabeth
    Zeitoun, Ralph I.
    Abou Haidar, Lea
    Cascorbi, Ingolf
    Zgheib, Nathalie Khoueiry
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 2019, 85 (09) : 2076 - 2088
  • [49] An international survey of the clinical practice of endoscopic ultrasonography (EUS)
    Das, A
    Mourad, W
    Lightdale, CJ
    Sivak, MV
    Yigit, J
    Chak, A
    GASTROINTESTINAL ENDOSCOPY, 2003, 57 (05) : AB250 - AB250
  • [50] DESIGN OF AN INTERNATIONAL SURVEY UPDATE OF CLINICAL PRACTICE GUIDELINES
    Carrasco, J. M.
    Alonso, P.
    Salcedo, F.
    Sola, I.
    Rico, R.
    Estrada, M. D.
    Gracia, J.
    Diaz, P.
    Rotaeche, R.
    GACETA SANITARIA, 2009, 23 : 200 - 200