T1 mapping from routine 3D T1-weighted inversion recovery sequences in clinical practice: comparison against reference inversion recovery fast field echo T1 scans and feasibility in multiple sclerosis

被引:0
|
作者
Young, Griffin [1 ]
Nguyen, Vivian S. [1 ]
Howlett-Prieto, Quentin [2 ]
Abuaf, Amanda Frisosky [3 ]
Carroll, Timothy J. [4 ]
Kawaji, Keigo [1 ]
Javed, Adil [5 ]
机构
[1] IIT, Biomed Engn, Chicago, IL USA
[2] Univ Illinois, Dept Neurol & Rehabil, Chicago, IL USA
[3] Univ Wisconsin, Dept Neurol, Madison, WI USA
[4] Univ Chicago, Dept Radiol, Chicago, IL USA
[5] Univ Chicago, Dept Neurol, 5841 South Maryland Ave, MC2030, Chicago, IL 60637 USA
关键词
T1; mapping; Multiple sclerosis; IR-FLASH; 3DT1-weighted scans; MAGNETIZATION-TRANSFER RATIO; NMR RELAXATION-TIMES; HIGH-RESOLUTION T-1; GREY-MATTER DAMAGE; WHITE-MATTER; HUMAN BRAIN; MRI; IRON; DISABILITY; QUANTIFICATION;
D O I
10.1007/s00234-024-03400-4
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and purpose Quantitative T1 mapping can be an essential tool for assessing tissue injury in multiple sclerosis (MS). We introduce T1-REQUIRE, a method that converts a single high-resolution anatomical 3D T1-weighted Turbo Field Echo (3DT1TFE) scan into a parametric T1 map that could be used for quantitative assessment of tissue damage. We present the accuracy and feasibility of this method in MS. Methods 14 subjects with relapsing-remitting MS and 10 healthy subjects were examined. T1 maps were generated from 3DT1TFE images using T1-REQUIRE, which estimates T1 values using MR signal equations and internal tissue reference T1 values. Estimated T1 of lesions, white, and gray matter regions were compared with reference Inversion-Recovery Fast Field Echo T1 values and analyzed via correlation and Bland-Altman (BA) statistics. Results 159 T1-weighted (T1W) hypointense MS lesions and 288 gray matter regions were examined. T1 values for MS lesions showed a Pearson's correlation of r = 0.81 (p < 0.000), R-2 = 0.65, and Bias = 4.18%. BA statistics showed a mean difference of -53.95 ms and limits of agreement (LOA) of -344.20 and 236.30 ms. Non-lesional normal-appearing white matter had a correlation coefficient of r = 0.82 (p < 0.000), R-2 = 0.67, Bias = 8.78%, mean difference of 73.87 ms, and LOA of -55.67 and 203.41 ms. Conclusions We demonstrate the feasibility of retroactively derived high-resolution T1 maps from routinely acquired anatomical images, which could be used to quantify tissue pathology in MS. The results of this study will set the stage for testing this method in larger clinical studies for examining MS disease activity and progression.
引用
收藏
页码:1709 / 1719
页数:11
相关论文
共 50 条
  • [31] Simultaneous T1 and T2 mapping of the carotid plaque (SIMPLE) with T2 and inversion recovery prepared 3D radial imaging
    Qi, Haikun
    Sun, Jie
    Qiao, Huiyu
    Zhao, Xihai
    Guo, Rui
    Balu, Niranjan
    Yuan, Chun
    Chen, Huijun
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (06) : 2598 - 2608
  • [32] MR T1-weighted inversion recovery imaging in detecting brain metastases: Could it replace T1-weighted spin-echo imaging?
    Qian, Y. -F.
    Yu, C. -L.
    Zhang, C.
    Yu, Y. -Q.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (04) : 701 - 704
  • [33] Degenerative disc disease of the lumbar spine: a prospective comparison of fast T1-weighted fluid-attenuated inversion recovery and T1-weighted turbo spin echo MR imaging
    Erdem, LO
    Erdem, CZ
    Acikgoz, B
    Gundogdu, S
    EUROPEAN JOURNAL OF RADIOLOGY, 2005, 55 (02) : 277 - 282
  • [34] T1-weighted fluid-attenuated inversion recovery and T1-weighted fast spin-echo contrast-enhanced imaging: A comparison in 20 patients with brain lesions
    Al-Saeed, O.
    Ismail, M.
    Athyal, R. P.
    Rudwan, M.
    Khafajee, S.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2009, 53 (04) : 366 - 372
  • [35] Utility of 3D Double Inversion Recovery Sequence in Paediatric Epilepsy and its Comparison to 3D Fluid Attenuation Inversion Recovery Sequence and T1 Inversion Recovery Sequence : A Cross-sectional Study
    Chelladurai, Amarnath
    Paraman, Chirtrarasan
    Kannappan, Sivakumar
    Muthaiyan, Priya
    Velappan, Guhan Ramasamy
    Thiyagarajan, Pradeebha
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2022, 16 (09) : TC5 - TC8
  • [36] T1-weighted fluid-attenuated inversion recovery at low field strength: A viable alternative for T1-weighted intracranial imaging
    Hori, M
    Okubo, T
    Uozumi, K
    Ishigame, K
    Kumagai, H
    Araki, T
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2003, 24 (04) : 648 - 651
  • [37] Comparison and calibration of MP2RAGE quantitative T1 values to multi-TI inversion recovery T1 values
    Saunders, Adam M.
    Kim, Michael E.
    Gao, Chenyu
    Remedios, Lucas W.
    Krishnan, Aravind R.
    Schilling, Kurt G.
    O'Grady, Kristin P.
    Smith, Seth A.
    Landman, Bennett A.
    MAGNETIC RESONANCE IMAGING, 2025, 117
  • [38] Feasibility of 3D MRI fingerprinting for rapid knee cartilage T1, T2, and T1ρ mapping at 0.55T: Comparison with 3T
    De Moura, Hector L.
    Monga, Anmol
    Zhang, Xiaoxia
    Zibetti, Marcelo V. W.
    Keerthivasan, Mahesh B.
    Regatte, Ravinder R.
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [39] A SIMPLE METHOD FOR THE RESTORATION OF SIGNAL POLARITY IN MULTIIMAGE INVERSION RECOVERY SEQUENCES FOR MEASURING T1
    GOWLAND, PA
    LEACH, MO
    MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (01) : 224 - 231
  • [40] HIGH-SPEED MULTISLICE T1 MAPPING USING INVERSION-RECOVERY ECHO-PLANAR IMAGING
    ORDIDGE, RJ
    GIBBS, P
    CHAPMAN, B
    STEHLING, MK
    MANSFIELD, P
    MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) : 238 - 245