Experimental investigation of wind pressures on photovoltaic (PV) panel installed parallel to residential gable roof

被引:3
|
作者
Yao, J. F. [1 ,2 ,3 ]
Tu, Z. B. [2 ]
Shen, G. H. [1 ]
Guo, Y. [3 ]
Wang, D. [3 ]
机构
[1] Zhejiang Univ, Inst Struct Engn, 866 Yuhangtang Rd, Hangzhou, Peoples R China
[2] Zhejiang Univ Water Resources & Elect Power, Coll Civil Engn & Architecture, Hangzhou, Peoples R China
[3] Energy Engn Grp Zhejiang Power Design Inst Co Ltd, Hangzhou, Peoples R China
关键词
Wind pressure; photovoltaic (PV) panel; Gable roof; Residential house; Clearance; SOLAR-ARRAYS; LOADS; BUILDINGS;
D O I
10.1016/j.solener.2024.112452
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The study was conducted to investigate the wind pressures on PV panels installed parallel to a 30 degrees pitched gable roof, with a special focus on the effects of roof clearance. The wind pressures on the two sides of the scaled panels with four clearances, i.e., ranging from 5 cm to 20 cm with an interval of 5 cm, were tested. The pressure coefficients over taps and zones were examined and discussed. The results show that the most critical positive and negative area-averaged peak net pressure coefficients were comparable in magnitude. With a clearance of 10 cm, the critical positive and negative values were 1.13 and -1.08, respectively, and both occurred at theta = 0 degrees. With effective area of 3.7 m2, the critical positive values increased 26.6 %, 8.3 % and 11.7 % as clearance ranged from 5 cm to 10 cm, 10 cm to 15 cm, and 15 cm to 20 cm, respectively, while the critical negative values changed little when clearance was less than 15 cm, but increased 18.8 % when clearance increased from 15 cm to 20 cm. However, the associated unfavorable wind directions of critical positive and negative values were at theta = 0 degrees, and oblique wind, respectively, remaining nearly unchanged with the increasing of clearance. The tested critical positive and negative area-averaged peak net pressure coefficients were smaller than the values calculated by standards, indicating that the wind resistant designs of roof-mounted PV panels according to the mentioned standards are quite conservation.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Design of a noise and wildlife optimized residential roof-top horizontal wind-turbine with PV integration
    Proulx, Alexander
    Bradley, Aidan J.
    Vose, Sara
    Thangaraj, Charles
    PROCEEDINGS 2016 EIGHTH ANNUAL IEEE GREEN TECHNOLOGIES CONFERENCE (GREENTECH 2016), 2016, : 73 - 77
  • [42] A multifunctional curved CIGS photovoltaic/thermal roof system: A numerical and experimental investigation
    Tian, Xinyi
    Wang, Jun
    Ji, Jie
    Wang, Chuyao
    Ke, Wei
    Yuan, Shuang
    ENERGY, 2023, 273
  • [43] Investigation into the impacts of design, installation, operation and maintenance issues on performance and degradation of installed solar photovoltaic (PV) systems
    Aboagye, Bernard
    Gyamfi, Samuel
    Ofosu, Eric Antwi
    Djordjevic, Sinisa
    ENERGY FOR SUSTAINABLE DEVELOPMENT, 2022, 66 : 165 - 176
  • [44] Experimental investigation on a series-parallel cluster of photovoltaic panels
    Kattakayam, TA
    Srinivasan, K
    SOLAR ENERGY, 1997, 61 (04) : 231 - 240
  • [45] Investigation into the impacts of design, installation, operation and maintenance issues on performance and degradation of installed solar photovoltaic (PV) systems
    Aboagye, Bernard
    Gyamfi, Samuel
    Ofosu, Eric Antwi
    Djordjevic, Sinisa
    Energy for Sustainable Development, 2022, 66 : 165 - 176
  • [46] Experimental investigation on the effect of photovoltaic panel partially and fully submerged in water
    Madhu, Balasubramanian
    Balasubramanian, Esakki
    Kabeel, Abd Elnaby
    Sathyamurthy, Ravishankar
    El-Agouz, El-Sayed
    Manokar, Athikesavan Muthu
    HEAT TRANSFER-ASIAN RESEARCH, 2019, 48 (05): : 1709 - 1721
  • [47] Experimental investigation of Effect of Dust Accumulation and Discoloration on Photovoltaic Panel Material
    Deepak
    Malvi, Chandra Shekhar
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2022, 44 (02) : 4427 - 4441
  • [48] Experimental investigation of a solar active facade-panel with integrated photovoltaic
    Neururer, Christoph
    Treberspurg, Martin
    Sterrer, Roland
    Brandl, Daniel
    BETON- UND STAHLBETONBAU, 2013, : 165 - 168
  • [49] Experimental investigation on the steel standing seam roof systems subjected to wind uplift
    Ravikanth Reddy, S.
    Arul Jayachandran, S.
    Journal of Structural Engineering (India), 2021, 48 (04): : 255 - 264
  • [50] Experimental investigation for an innovative hybrid photovoltaic/Thermal (PV/T) solar system
    Chiang, Weiming
    Permana, Indra
    Wang, Fujen
    Chen, Hungcheng
    Erdenebayar, Munkhtsooj
    ENERGY REPORTS, 2022, 8 : 910 - 918