Long-term humidity exposure of ATLAS18 ITk strip sensors

被引:0
|
作者
Fadeyev, V. [1 ]
Affolder, A. [1 ]
Dowling, A. [1 ]
Fernandez-Tejero, J. [2 ,3 ]
Gunnell, J. [1 ]
Kang, N. [1 ]
Martinez-Mckinney, F. [1 ]
Paddock, Q. [1 ]
Ullan, M. [4 ]
Unno, Y. [5 ]
Yarwick, J. [1 ]
机构
[1] Univ Calif Santa Cruz, Santa Cruz Inst Particle Phys, 1156 High St, Santa Cruz, CA 95064 USA
[2] Simon Fraser Univ, Dept Phys, 8888 Univ Dr, Burnaby, BC V5A 1S6, Canada
[3] TRIUMF, 4004 Wesbrook Mall, Vancouver, BC V6T 2A3, Canada
[4] CSIC, Inst Microelect Barcelona, CNM, Campus UAB Bellaterra, Barcelona 08193, Spain
[5] High Energy Accelerator Res Org KEK, Inst Particle & Nucl Study, 1-1 Oho, Tsukuba, Ibaraki 3050801, Japan
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会;
关键词
Silicon; Detector; Humidity; Breakdown;
D O I
10.1016/j.nima.2024.169430
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The ATLAS collaboration is upgrading its detector for High-Luminosity LHC (HL-LHC) operations scheduled to start in 2029. This involves making a new all-silicon tracker, called Inner Tracker (ITk), with instrumented strip area of 165 m 2 . The strip sensor type is n-on-p, chosen because of its radiation hardness and a relative fabrication simplicity. So far, this technology has not been used in large-scale experiments. Many years of R&D investigations and preproduction experience showed that it works well, with the specification of the maximum operational voltage of 500 V. The sensors, however, show sensitivity to ambient humidity, e.g. reduced breakdown voltage at relative humidity (RH) values of about 40% and above. This is an issue for testability, but not for real operations, where RH is very low. Therefore, the collaboration adopted the strategy of dry storage, testing, and shipment for sensors and related assembled components: modules, staves, and petals. A few days long exposure to ambient air during assembly was shown to be tolerable. The dry handling strategy becomes much more difficult to implement during the tracker integration, when barrels and disks are put together in large-size cleanrooms with RH range between 50 and 70%. The duration of each of numerous integration steps is several weeks, followed by testing. The effect of such long humidity exposures on the sensor properties was unknown. Therefore, we commenced a study of repeated sensor exposures to 75% RH. We chose 32 sensors for the study from different deliveries, and with different pedigrees in terms of initial performance on reception and recovery procedures used. Progressively longer exposures ranged between 4 and 266 days in duration. The cumulative exposure time was up to 2 years. No performance deterioration was seen, as evaluated by the visual inspection, IV characteristics, and other checks. We report the details of the tests, results, and implications.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Thickness swelling of oriented strandboard under long-term cyclic humidity exposure condition
    Wu, QL
    Lee, JN
    WOOD AND FIBER SCIENCE, 2002, 34 (01): : 125 - 139
  • [22] Long-Term Effects of Relative Humidity on the Performance of ZnO-Based MEMS Acoustic Sensors
    Prasad, Mahanth
    Sahula, Vineet
    Khanna, Vinod Kumar
    IEEE TRANSACTIONS ON DEVICE AND MATERIALS RELIABILITY, 2014, 14 (02) : 778 - 780
  • [23] Long-term exposure to Ozone
    Boeckelmann, I.
    PNEUMOLOGE, 2009, 6 (04): : 243 - 244
  • [24] Effect of irradiation and annealing performed with bias voltage applied across the coupling capacitors on the interstrip resistance of ATLAS ITk silicon strip sensors
    Kroll J.
    Allport P.P.
    Chisholm A.
    Dudáš D.
    Fadeyev V.
    George W.
    Gonella L.
    Kopsalis I.
    Kvasnička J.
    Latoňová V.
    Lomas J.
    Martinez-Mckinney F.
    Mikeštíková M.
    Shi X.
    Tůma P.
    Ullan M.
    Unno Y.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2023, 1047
  • [25] LONG-TERM SELENIUM EXPOSURE
    DISKIN, CJ
    TOMASSO, CL
    ALPER, JC
    GLASER, ML
    FLIEGEL, SE
    ARCHIVES OF INTERNAL MEDICINE, 1979, 139 (07) : 824 - 826
  • [26] Long-term experiments and strip plot designs
    Plaia, Antonella
    JOURNAL OF APPLIED STATISTICS, 2015, 42 (12) : 2639 - 2653
  • [27] Sensors for long-term construction monitoring
    Slowik, V
    Klink, T
    Krummbach, R
    GESA-SYMPOSIUM 2001: SICHERHEIT UND ZUVERLASSIGKEIT DURCH EXPERIMENTELLE STRUKTUR-UND BEANSPRUCHUNGSANALYSE, 2001, 1599 : 135 - 140
  • [28] Long-term exposure to summer specific humidity and cardiovascular disease hospitalizations in the US Medicare population
    Klompmaker, Jochem O.
    Laden, Francine
    James, Peter
    Sabath, M. Benjamin
    Wu, Xiao
    Dominici, Francesca
    Zanobetti, Antonella
    Hart, Jaime E.
    ENVIRONMENT INTERNATIONAL, 2023, 179
  • [29] Characterization of sorption behavior of oriented strandboard under long-term cyclic humidity exposure condition
    Wu, QL
    Ren, YK
    WOOD AND FIBER SCIENCE, 2000, 32 (04): : 404 - 418
  • [30] PERFORMANCE EVALUATION OF STRIP PARQUET FLOORING PANELS AFTER LONG-TERM, IN-SERVICE EXPOSURE
    Nemeth, Rebert
    Posch, Paula Molnarne
    Molnar, Sandor
    Bak, Miklos
    DREWNO, 2014, 57 (193): : 119 - 134