Design and Stiffness Control of a Variable-Length Continuum Robot for Endoscopic Surgery

被引:0
|
作者
Zhang, Jingyu [1 ,2 ]
Fang, Qin [1 ,2 ]
Liu, Lilu [1 ,2 ]
Jin, Rui [1 ,2 ]
Xiang, Pingyu [1 ,2 ]
Xiong, Rong [1 ,2 ]
Wang, Yue [1 ,2 ]
Lu, Haojian [1 ,2 ,3 ,4 ]
机构
[1] Zhejiang Univ, State Key Lab Ind Control & Technol, Hangzhou 310027, Peoples R China
[2] Zhejiang Univ, Inst Cyber Syst & Control, Hangzhou 310027, Peoples R China
[3] Zhejiang Univ, Canc Ctr, Stomatol Hosp, Zhejiang Prov Clin Res Ctr Oral Dis,Sch Med,Key La, Hangzhou 310000, Peoples R China
[4] Zhejiang Univ, Engn Res Ctr Oral Biomat & Devices Zhejiang Prov, Sch Med, Hangzhou 310000, Peoples R China
基金
中国国家自然科学基金;
关键词
Robots; Catheters; Surgery; Bending; Force; Fabrication; Motors; Soft robots; small-scale robot; variable length; variable stiffness; endoscopic surgery;
D O I
10.1109/TASE.2024.3418092
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Continuum robots, owing to their inherent compliance, have become essential in endoscopic surgical procedures, such as mucosal ablation. However, the prevalent design of endoscopic manipulators, which typically features only a single active bending segment, often results in limited dexterity and accessibility. Additionally, the incorporation of variable stiffness in these robots has attracted significant interest, with the aim to improve manipulation capabilities in confined spaces. In the paper, we propose a novel variable-length continuum robot with variable stiffness for endoscopic surgery. The robot's stiffness can be altered either by modifying the catheter's length or solid-liquid transition of low-melting-point alloy (LMPA). The design and fabrication methods of the robot are meticulously detailed. Additionally, a quasi-static stiffness model along with a learning-based stiffness compensation approach for accurate stiffness estimation are proposed. Leveraging this model, a contact force controller is designed for ablation procedure. The experimental results show that our robot possesses good flexibility and accessibility, making it highly adept at manipulating in confined spaces. Its variable stiffness feature significantly enhances its ability to counteract external disturbance and prevent tip deformation (with a average position change of 1.1mm). Finally, through force control experiments and a surgical demonstration in a gastrointestinal model, we have further validated the robot's applicability in surgical contexts. Note to Practitioners-This paper proposed a variable-length continuum robot with variable stiffness for endoscopic surgery. The robot can achieve axial elongation and omnidirectional bending motion, having better dexterity and accessibility than traditional medical continuum robots with one active bending segment. The robot's stiffness can be adjusted by the length changes or solid-liquid transition of low-melting-point alloy (LMPA). Besides, an accurate stiffness model and a contact force controller are proposed for endoscopic ablation surgery. By experimental results, the robot shows high flexibility and accessibility, allowing access to confined spaces for manipulation, and good control accuracy and variable stiffness capability for endoscopic surgery.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Design and Modelling of Continuum Robot for Endoscopic Submucosal Dissection Surgery With Lifting Force Estimation
    Zhang, Xingyao
    Du, Fuxin
    Zhang, Gang
    Wu, Ke
    Zheng, Gang
    Li, Yibin
    Song, Rui
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2024, 20 (05):
  • [32] Design and Development of a Continuum Robot with Switching-Stiffness
    Shen, Donghua
    Zhang, Qi
    Han, Yali
    Tu, Chunlei
    Wang, Xingsong
    SOFT ROBOTICS, 2023, 10 (05) : 1015 - 1027
  • [33] Variable-length segmental transmission line and its design guidelines
    Koizumi N.
    Hayashi K.
    Yasunaga M.
    Yamamori K.
    Yoshihara I.
    Artificial Life and Robotics, 2008, 12 (1-2) : 214 - 218
  • [34] Single channel pipelined variable-length FFT processor design
    Wang, Jiale
    Xie, Yizhuang
    Yang, Chen
    JOURNAL OF ENGINEERING-JOE, 2019, 2019 (21): : 7709 - 7712
  • [35] Hybrid Architecture Design for Calculating Variable-Length Fourier Transform
    Lai, Shin-Chi
    Juang, Wen-Ho
    Lee, Yueh-Shu
    Chen, Shin-Hao
    Chen, Ke-Horng
    Tsai, Chia-Chun
    Lee, Chiung-Hon
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2016, 63 (03) : 279 - 283
  • [36] BIPED ROBOT DESIGN WITH VARIABLE ANKLE STIFFNESS
    Zang, Xizhe
    Lin, Zhenkun
    Sun, Xinran
    Liu, Yixiang
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (07)
  • [37] Self-tuning swing control of a variable-length pendulum
    Sogo, H
    Matsumoto, A
    Yamamoto, T
    ADAPTATION AND LEARNING IN CONTROL AND SIGNAL PROCESSING 2001, 2002, : 377 - 382
  • [38] DESIGN OF A VARIABLE-LENGTH PIEZOCOMPOSITE TRANSDUCER FOR STRUCTURAL HEALTH MONITORING
    Salas, Ken I.
    Cesnik, Carlos E. S.
    SMASIS 2008: PROCEEDINGS OF THE ASME CONFERENCE ON SMART MATERIALS, ADAPTIVE STRUCTURES AND INTELLIGENT SYSTEMS - 2008, VOL 2, 2009, : 47 - 56
  • [39] A continuum manipulator for continuously variable stiffness and its stiffness control formulation
    Zhao, Bin
    Zeng, Lingyun
    Wu, Zhonghao
    Xu, Kai
    MECHANISM AND MACHINE THEORY, 2020, 149 (149)
  • [40] A SPHINCTEROTOME WITH VARIABLE-LENGTH WIRE FOR EASIER ENDOSCOPIC SPHINCTEROTOMY AND QUICKER BILIARY DRAINAGE
    TANAKA, M
    OGAWA, Y
    KIMURA, H
    NARITOMI, G
    GASTROINTESTINAL ENDOSCOPY, 1995, 41 (03) : 244 - 246