Robotic-assisted total knee arthroplasty is associated with the use of thinner polyethylene liners compared to navigation-guided and manual techniques

被引:1
|
作者
Cheng, Ryan [1 ]
Kim, Billy [1 ]
Taylor, Walter L. [1 ]
Westrich, Geoffrey H. [1 ]
Shen, Tony S. [1 ]
机构
[1] Hosp Special Surg, Dept Adult Reconstruct & Joint Replacement, New York, NY 10021 USA
关键词
bony resection; intraoperative technology; polyethylene liners; primary total knee arthroplasty; robotics;
D O I
10.1002/ksa.12228
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to examine the effects of intraoperative technology use on the rate of using polyethylene liners 15 mm or greater during primary total knee arthroplasty (TKA). Methods: There were 103,295 implants from 16,386 primary unilateral TKAs performed on 14,253 patients at a single institution between 1 January 2018, and 30 June 2022, included in the current study. Robotic assistance and navigation guidance were used in 1274 (8%) and 8345 (51%) procedures, respectively. The remaining 6767 TKAs (41%) were performed manually. Polyethylene liners were manually identified and further subcategorised by implant thickness. Patients who underwent robotic-assisted TKA were younger (p < 0.001) and more likely to be male (p < 0.001) compared to patients who underwent navigation-guided or manual TKAs. Results: Average polyethylene liner thickness was similar between groups (10.5 +/- 1.5 mm for robotic-assisted TKAs, 10.9 +/- 1.8 mm for navigation-guided TKAs and 10.8 +/- 1.8 mm for manual TKAs). The proportions of polyethylene liners 15 mm or greater used were 4.9%, 3.8% and 1.9% for navigation-guided, manual and robotic-assisted procedures, respectively (p < 0.001). Multivariate regression analyses demonstrated that navigation-guided (odds ratio [OR]: 2.6, 95% confidence Interval [CI]: [1.75-4.07], p < 0.001) and manual (OR: 2.0, 95% CI: [1.34-3.20], p = 0.001) procedures were associated with an increased use of polyethylene liners 15 mm or greater. Conclusion: Robotic-assisted TKA was associated with a lower proportion of polyethylene liners 15 mm or greater used compared to navigation-guided and manual TKA. These findings suggest that robotic assistance can reduce human error via a more precise cutting system, limit over-resection of the tibia and flexion-extension gap mismatch and ultimately allow for more appropriately sized implants.
引用
收藏
页码:2290 / 2296
页数:7
相关论文
共 50 条
  • [21] The Current Role of Robotic-assisted Total Knee Arthroplasty
    Rodriguez-Merchan, E. Carlos
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2022, 10 (12): : 989 - 991
  • [22] Robotic-assisted total knee arthroplasty demonstrates decreased postoperative pain and opioid usage compared to conventional total knee arthroplasty
    Bhimani, S. J.
    Bhimani, R.
    Smith, A.
    Eccles, C.
    Smith, L.
    Malkani, A.
    BONE & JOINT OPEN, 2020, 1 (02): : 8 - 12
  • [23] What are the benefits of robotic-assisted total knee arthroplasty over conventional manual total knee arthroplasty? A systematic review of comparative studies
    Mancino, Fabio
    Cacciola, Giorgio
    Malahias, Michael-Alexander
    De Filippis, Roberto
    De Marco, Davide
    Di Matteo, Vincenzo
    Gu, A.
    Sculco, Peter K.
    Maccauro, Giulio
    De Martino, Ivan
    ORTHOPEDIC REVIEWS, 2020, 12 : 15 - 22
  • [24] Opioid Use in Robotic-Arm Assisted Total Knee Arthroplasty: A Comparison to Conventional Manual Total Knee Arthroplasty
    Greiner, Justin J.
    Hetzel, Scott J.
    Wang, Jesse F.
    Lee, Eric J.
    Mitchell, Joseph
    Illgen, Richard L.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2020, 37
  • [25] Patient-Reported Outcomes in Robotic-Assisted vs Manual Cementless Total Knee Arthroplasty
    Stoltz, Michael J.
    Smith, Nolan S.
    Abhari, Sarag
    Whitaker, John
    Baker, James F.
    Smith, Langan S.
    Bhimani, Rohat
    Yakkanti, Madhusudhan R.
    Malkani, Arthur L.
    ARTHROPLASTY TODAY, 2024, 30
  • [26] Robotic-assisted unicompartmental knee arthroplasty has a greater early functional outcome when compared to manual total knee arthroplasty for isolated medial compartment arthritis
    Clement, N. D.
    Bell, A.
    Simpson, P.
    Macpherson, G.
    Patton, J. T.
    Hamilton, D. F.
    BONE & JOINT RESEARCH, 2020, 9 (01): : 15 - 22
  • [27] Robotic-Arm Assisted Total Knee Arthroplasty Demonstrated Greater Accuracy and Precision to Plan Compared with Manual Techniques
    Hampp, Emily L.
    Chughtai, Morad
    Scholl, Laura Y.
    Sodhi, Nipun
    Bhowmik-Stoker, Manoshi
    Jacofsky, David J.
    Mont, Michael A.
    JOURNAL OF KNEE SURGERY, 2019, 32 (03) : 239 - 250
  • [28] Robotic-Assisted Versus Manual Unicompartmental Knee Arthroplasty: A Systematic Review
    Iturriaga, Cesar
    Salem, Hytham S.
    Sodhi, Nipun
    Ehiorobo, Joseph O.
    Mont, Michael A.
    SURGICAL TECHNOLOGY INTERNATIONAL-INTERNATIONAL DEVELOPMENTS IN SURGERY AND SURGICAL RESEARCH, 2020, 37
  • [29] The Impact of Robotic-Assisted Total Knee Arthroplasty on Resident Training
    Duensing, Ian M.
    Stewart, Wells
    Novicoff, Wendy M.
    Meneghini, R. Michael
    Browne, James A.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (06): : S227 - S231
  • [30] Evaluating the cost of robotic-assisted total and unicompartmental knee arthroplasty
    Alexander, Kate
    Karunaratne, Sascha
    Sidhu, Verinder
    Fritsch, Brett
    Gupta, Sanjeev
    Horsley, Mark
    Guzman, Maurice
    Boyle, Richard
    Mcbride, Kate
    Steffens, Daniel
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)