Theoretical interpretation of W soft X-ray spectra collected by the pulse height analysis system on Wendelstein 7-X stellarator

被引:1
|
作者
Syrocki, L. [1 ]
Kubkowska, M. [1 ]
Jablonski, S. [1 ]
Neuner, U. [2 ]
机构
[1] Inst Plasma Phys & Laser Microfus, Hery 23, PL-01497 Warsaw, Poland
[2] Max Planck Inst Plasma Phys, Greifswald, Germany
关键词
D O I
10.1063/5.0210977
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
In many fusion devices, such as tokamaks or stellarators like Wendelstein 7-X (W7-X), soft x-ray pulse height analysis (PHA) system diagnostics are routinely used during the experiments. The PHA system is dedicated to providing information about the impurity content, and average along line-of-sight electron temperature in the plasma conditions. Moreover, it is also able to estimate impurity density and an average effective charge from the comparison of experimental spectra with the modeled ones. However, the experimental x-ray spectra can be interpreted in terms of interesting plasma parameters only when the theoretical radiation models first identify and then take into account all the relevant factors that affect the spectrum. Therefore, for this purpose, a theoretical model has been applied. Flexible Atomic Code, which allows for calculation of various atomic properties such as energy levels, cross sections for excitation and ionization by electron impact, transition probabilities for radiative transitions and autoionization, and any others as needed in the collisional-radiative approximation. The chosen spectra collected during the W7-X campaign (OP1.2b) were examined, trying to obtain an agreement between the observed and simulated spectra. The analysis carried out allowed for a reliable interpretation of experimental x-ray spectra, estimation of the electron temperature, and obtaining information on the content of tungsten impurities.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] The Superconducting Magnet System of the Stellarator Wendelstein 7-X
    Rummel, Thomas
    Risse, Konrad
    Ehrke, Gunnar
    Rummel, Kerstin
    John, Andre
    Moennich, Thomas
    Buscher, Klaus-Peter
    Fietz, Walter H.
    Heller, Reinhard
    Neubauer, Olaf
    Panin, Anatoly
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2012, 40 (03) : 769 - 776
  • [12] The superconducting magnet system for the Wendelstein 7-X Stellarator
    Sapper, J
    FUSION TECHNOLOGY, 1996, 30 (03): : 1234 - 1240
  • [13] The superconducting magnet system of the stellarator Wendelstein 7-X
    Rummel, Thomas
    Risse, Konrad
    Ehrke, Gunnar
    Rummel, Kerstin
    John, Andre
    Moennich, Thomas
    Buscher, Klaus-Peter
    Fietz, Walter
    Heller, Reinhard
    Neubauer, Olaf
    Panin, Anatoly
    2011 IEEE/NPSS 24TH SYMPOSIUM ON FUSION ENGINEERING (SOFE), 2011,
  • [14] The Dedicated ICRH System for the Stellarator Wendelstein 7-X
    Ongena, J.
    Messiaen, A.
    Dumortier, P.
    Durodie, F.
    Kazakov, Ye O.
    Louche, F.
    Schweer, B.
    Vervier, M.
    Van Eester, D.
    Koch, R.
    Krivska, A.
    Lyssoivan, A.
    Van Schoor, M.
    Wauters, T.
    Borsuk, V.
    Neubauer, O.
    Schmitz, O.
    Offermans, G.
    Altenburg, Y.
    Baylard, C.
    Birus, D.
    Bozhenkov, S.
    Hartmann, D. A.
    Kallmeyer, J.
    Renard, S.
    Wolf, R.
    RADIOFREQUENCY POWER IN PLASMAS, 2014, 1580 : 105 - 112
  • [15] The magnet system of Wendelstein 7-X stellarator in operation
    Risse, Konrad
    Rummel, Thomas
    Bosch, Hans-Stephan
    Bykov, Victor
    Carls, Andre
    Fuellenbach, Frank
    Moennich, Thomas
    Nagel, Michael
    FUSION ENGINEERING AND DESIGN, 2018, 136 : 12 - 16
  • [16] Simulation of pulse height analysis soft X-ray spectra expected from W7-X
    Jablonski, S.
    Czarnecka, A.
    Kubkowska, M.
    Ryc, L.
    Weller, A.
    Biedermann, C.
    Koenig, R.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [17] Overdense plasma heating in Wendelstein 7-X(W7-X) stellarator
    Adlparvar, S.
    Miraboutalebi, S.
    Kiai, S. M. Sadat
    Rajaee, L.
    RESULTS IN PHYSICS, 2017, 7 : 1965 - 1970
  • [18] Plasma impurities observed by a pulse height analysis diagnostic during the divertor campaign of the Wendelstein 7-X stellarator
    Kubkowska, M.
    Czarnecka, A.
    Fornal, T.
    Gruca, M.
    Jablonski, S.
    Krawczyk, N.
    Ryc, L.
    Burhenn, R.
    Buttenschon, B.
    Geiger, B.
    Grulke, O.
    Langenberg, A.
    Marchuk, O.
    McCarthy, K. J.
    Neuner, U.
    Nicolai, D.
    Pablant, N.
    Schweer, B.
    Thomsen, H.
    Wegner, Th.
    Drews, P.
    Hollfeld, K. -P.
    Killer, C.
    Krings, Th.
    Offermanns, G.
    Satheeswaran, G.
    Kunkel, F.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [19] X-ray multi camera tomography system of Wendelstein 7-X
    Klose, S
    Weller, A
    Schötz, P
    Werner, A
    Greve, H
    ADVANCED DIAGNOSTICS FOR MAGNETIC AND INERTIAL FUSION, 2002, : 229 - 232
  • [20] Concepts of x-ray diagnostics for WENDELSTEIN 7-X
    Weller, A
    Mohr, S
    Junghans, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3962 - 3965