Standalone hybrid power-hydrogen system incorporating daily-seasonal green hydrogen storage and hydrogen refueling station

被引:11
|
作者
Hemmati, Reza [1 ]
Bornapour, Seyyed Mohammad [2 ]
Saboori, Hedayat [1 ]
机构
[1] Kermanshah Univ Technol, Dept Elect Engn, Kermanshah 6715685420, Iran
[2] Univ Yasuj, Fac Engn, Elect Engn Dept, Yasuj, Iran
关键词
Electric vehicle; Fuelcell vehicle; Integrated electricity -hydrogen system; Renewable energy; Seasonal hydrogen storage; ENERGY;
D O I
10.1016/j.energy.2024.131122
中图分类号
O414.1 [热力学];
学科分类号
摘要
In light of the recent developments in the green hydrogen industry, it is essential to investigate its compatibility and integration with existing electrical grids. This task becomes more challenging when considering its implementation in off-grid sites that solely rely on renewable energy. In cases where off-grid sites should provide electricity and hydrogen to a variety of consumers, it is compulsory to have electrical and hydrogen storage devices with long-term storage capabilities. Consequently, a precise programming technique is necessary to manage the storage and consumption of hydrogen and electricity. To investigate such a model, this paper presents a connected electricity-hydrogen grid in which all the required energy is supplied by solar and hydroelectric units. This off-grid system supplies the necessary energy for industrial and residential loads, electric vehicle charging stations, fuelcell car refueling stations, and natural gas pipelines. The power-to-hydrogen (P2H) and hydrogen-to-power (H2P) systems are used to facilitate energy flow between the electrical and hydrogen sectors. A daily-seasonal hydrogen storage is integrated as well. The proposed method contributes by integrating and improving the modeling, management, optimization, and operation of the daily-seasonal hydrogen storage and electrical storage. Its primary objective is to supply electricity and hydrogen to various consumers using solely renewable energy, even in the face of renewable energy fluctuations and outages. The model is mathematically expressed as a mixed integer linear optimization, implemented in GAMS software, and solved by the CPLEX solver. It aims at maximizing profit from selling electricity and hydrogen to the users. Results demonstrate that P2H and H2P units have a complementary operation with the solar system. When there is abundant solar energy, the P2H converts excess clean energy to green hydrogen and H2P operates when solar energy is not available. Seasonal storage also stores hydrogen from spring to autumn and discharges it in winter because of higher hydrogen prices in this season. Such an operation increases the annual profit by about 9%. When the hydroelectricity unit faces an outage in hours 8 to 13, the fuelcell uses the stored hydrogen and comes into operation to compensate hydropower outage. The net present value of profit amounts to $275,179 per year. The total hydrogen required is approximately 49,870 kg per year, with a total electricity requirement of 1190 MWh per year. The levelized revenue from hydrogen is achieved at around $4 per kilogram, while the levelized revenue from electricity is about $0.058 per kilowatt-hour. It is concluded that the integration of seasonal storage effectively reduces costs, boosts profits, and efficiently manages renewable energy fluctuations across different seasons.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Hydrogen refueling station compression and storage optimization with tube-trailer deliveries
    Reddi, Krishna
    Elgowainy, Amgad
    Sutherland, Erika
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (33) : 19169 - 19181
  • [22] Sizing, Optimization, and Financial Analysis of a Green Hydrogen Refueling Station in Remote Regions
    Kavadias, Kosmas A.
    Kosmas, Vasileios
    Tzelepis, Stefanos
    ENERGIES, 2022, 15 (02)
  • [23] Comparison of Different Coupling Modes between the Power System and the Hydrogen System Based on a Power-Hydrogen Coordinated Planning Optimization Model
    Zhang, Siyu
    Zhang, Ning
    Dai, Hongcai
    Liu, Lin
    Zhou, Zhuan
    Shi, Qing
    Lu, Jing
    ENERGIES, 2023, 16 (14)
  • [24] Business analysis of the hydrogen refueling station infrastructure and the role of the pricing system
    Michalski, Jan
    Buenger, Ulrich
    Stiller, Christoph
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (13) : 8152 - 8157
  • [25] Design of grid connected-PV system for a hydrogen refueling station
    Deshmukh, Sachin
    Baghzouz, Yahia
    Boehm, Robert F.
    PROCEEDINGS OF THE ASME INTERNATIONAL SOLAR ENERGY CONFERENCE, 2007, : 171 - 175
  • [26] Hybrid neural network-based surrogate model for fast prediction of hydrogen leak consequences in hydrogen refueling station
    He, Xu
    Kong, Depeng
    Yang, Guodong
    Yu, Xirui
    Wang, Gongquan
    Peng, Rongqi
    Zhang, Yue
    Dai, Xinyi
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 59 : 187 - 198
  • [27] Optimal Planning for Electricity-Hydrogen Integrated Energy System Considering Power to Hydrogen and Heat and Seasonal Storage
    Pan, Guangsheng
    Gu, Wei
    Lu, Yuping
    Qiu, Haifeng
    Lu, Shuai
    Yao, Shuai
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2020, 11 (04) : 2662 - 2676
  • [28] Component and system levels limitations in power-hydrogen systems: Analytical review
    Sahraie, Elahe
    Kamwa, Innocent
    Moeini, Ali
    Mohseni-Bonab, Seyed Masoud
    ENERGY STRATEGY REVIEWS, 2024, 54
  • [29] Modeling and analysis of a solar thermal-photovoltaic-hydrogen-based hybrid power system for running a standalone cold storage
    De, Ramen Kanti
    Ganguly, A.
    JOURNAL OF CLEANER PRODUCTION, 2021, 293
  • [30] Effect of operation conditions on the structural and fatigue behaviors of hydrogen storage vessel in refueling station
    Lee, Jongsuk
    Kim, Sunghan
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2025, 97 : 469 - 482