Ultrasensitive Fluorescent Microsensors Based on Aptamers Modified with SYBR Green I for Visual Quantitative Detection of Organophosphate Pesticides

被引:6
|
作者
Zhang, Qianru [1 ,2 ,3 ]
Liu, Anqi [1 ]
Song, Xin [4 ]
Xu, Shihao [1 ]
Da, Liangguo [3 ]
Lin, Dan [1 ,5 ]
Jiang, Changlong [1 ,5 ]
机构
[1] Chinese Acad Sci, Inst Solid State Phys, Hefei Inst Phys Sci, Hefei 230031, Anhui, Peoples R China
[2] Univ Sci & Technol China, Dept Chem, Hefei 230026, Peoples R China
[3] Huainan Normal Univ, Sch Chem & Mat Engn, Huainan 232038, Anhui, Peoples R China
[4] Hefei Publ Secur Bur, Hefei 230001, Anhui, Peoples R China
[5] Chinese Acad Sci, State Key Lab Transducer Technol, Hefei 230031, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
INTRINSIC FLUORESCENCE; QUADRUPLEX DNA; NANOPARTICLES; PROFENOFOS; SELECTION; SEQUENCE; G-C3N4;
D O I
10.1021/acs.analchem.4c01307
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Organophosphate pesticides (OPs) are widely utilized in agricultural production, and the residues threaten public health and environmental safety due to their toxicity. Herein, a novel and simple DNA aptamer-based sensor has been fabricated for the rapid, visual, and quantitative detection of profenofos and isocarbophos. The proposed DNA aptamers with a G-quadruplex spatial structure could be recognized by SYBR Green I (SG-I), resulting in strong green fluorescence emitted by SG-I. The DNA aptamers exhibit a higher specific binding ability to target OP molecules through aromatic ring stacking, disrupting the interaction between SG-I and DNA aptamers to induce green fluorescence quenching. Meanwhile, the fluorescence wavelength of G-quadruplex fluorescence emission peaks changes, accompanied by an obvious fluorescence variation from green to blue. SG-I-modified aptasensor without any additive reference fluorescence units for use in multicolor fluorescence assay for selective monitoring of OPs was first developed. The developed aptasensor provides a favorable linear range from 0 to 200 nM, with a low detection limit of 2.48 and 3.01 nM for profenofos and isocarbophos, respectively. Moreover, it offers high selectivity and stability in real sample detection with high recoveries. Then, a self-designed portable smartphone sensing platform was successfully used for quantitative result outputs, demonstrating experience in designing a neotype sensing strategy for point-of-care pesticide monitoring.
引用
收藏
页码:9636 / 9642
页数:7
相关论文
共 50 条
  • [21] Detection of PCV2 DNA by SYBR Green I-based quantitative PCR附视频
    HABIB Mudasser
    Journal of Zhejiang University(Science B:An International Biomedicine & Biotechnology Journal), 2007, (03) : 162 - 169
  • [22] A label-free fluorescent aptamer sensor for testosterone based on SYBR Green I
    Hou, Yucui
    Lu, Xiaoling
    Yang, Jie
    Tang, Chunhua
    Jiang, Hanbing
    Cai, Tongji
    Chen, Meilun
    Wei, Zheng
    Yu, Peng
    ANALYTICAL METHODS, 2023, 15 (12) : 1546 - 1552
  • [23] Quantitative Determination of Sequence-specific Nucleic Acid Based on Fluorescent Labeled DNA Probe and Dye SYBR Green I
    Zheng Ai-Hua
    Zhu Qing
    Xiang Dong-Shan
    He Zhi-Ke
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (03) : 325 - 329
  • [24] Combination of SYBR Green II and TaqMan Probe in the adulteration detection of Dendrobium devonianum by fluorescent quantitative PCR
    Yan, Wenjin
    Zhang, Jingzi
    Zheng, Rui
    Sun, Yulong
    Ren, Jie
    Ding, Xiaoyu
    INTERNATIONAL JOURNAL OF FOOD SCIENCE AND TECHNOLOGY, 2015, 50 (12): : 2572 - 2578
  • [25] Ultrasensitive microRNA-21 detection based on DNA hybridization chain reaction and SYBR Green dye
    Li, Zhi
    Li, Bingchen
    Zhou, Yunlei
    Yin, Huanshun
    Wang, Jun
    Ai, Shiyun
    ANALYTICAL BIOCHEMISTRY, 2017, 538 : 20 - 25
  • [26] A recombinase polymerase amplification-SYBR Green I assay for the rapid and visual detection of Brucella
    Chang, Jiang
    Wang, Nan
    Zhan, Jun-Peng
    Zhang, Shi-Jun
    Zou, De-Ying
    Li, Feng
    Zhang, Ying
    Li, Yan-Song
    Hu, Pan
    Lu, Shi-Ying
    Liu, Zeng-Shan
    Ren, Hong-Lin
    FOLIA MICROBIOLOGICA, 2024, 69 (04) : 767 - 774
  • [27] Development of a SYBR-Green I quantitative PCR assay for the detection and genotyping of different hantaviruses
    Liu, Ziyu
    Wang, Fang
    Yuan, Lijuan
    Zhang, Xiaoxiao
    Ying, Qikang
    Yu, Lan
    Zhang, Liang
    Cheng, Linfeng
    Zhang, Fanglin
    Lu, Jianguo
    Wu, Xing'an
    INTERNATIONAL JOURNAL OF MOLECULAR MEDICINE, 2016, 38 (03) : 951 - 960
  • [28] Rapid visual detection of anisakid nematodes using recombinase polymerase amplification and SYBR Green I
    Chen, Xiuqin
    Zhao, Lianjing
    Wang, Jiahui
    Wang, Haolu
    Qiu, Yangyuan
    Dong, Zijian
    Zhang, Chunling
    Liu, Mingyuan
    Wang, Xuelin
    Bai, Xue
    FRONTIERS IN MICROBIOLOGY, 2022, 13
  • [29] RPA-SYBR Green I based instrument-free visual detection for pathogenic Yersinia enterocolitica in meat
    Zheng, Yu
    Hu, Pan
    Ren, Honglin
    Wang, Han
    Cao, Qi
    Zhao, Qiang
    Li, Hanxiao
    Zhang, Hailing
    Liu, Zhanxu
    Li, Yansong
    Wang, Cong
    Liu, Zengshan
    Lu, Shiying
    ANALYTICAL BIOCHEMISTRY, 2021, 621 (621)
  • [30] Fluorescent Probe for Ag+ Detection Using SYBR GREEN I and C-C Mismatch
    Zhou, Xiaohong
    Memon, Abdul Ghaffar
    Sun, Weiming
    Fang, Fang
    Guo, Jinsong
    BIOSENSORS-BASEL, 2021, 11 (01):