Evaluation of compact pulsed lasers for two-photon microscopy using a simple method for measuring two-photon excitation efficiency

被引:3
|
作者
Saidi, Samir [1 ]
Shtrahman, Matthew [2 ]
机构
[1] Univ Calif San Diego, Shu Chien Gene Lay Dept Bioengn, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Neurosci, La Jolla, CA 92093 USA
关键词
two-photon microscopy; ultrashort pulsed lasers; fiber lasers; fluorescence; excitation efficiency; pulse quality;
D O I
10.1117/1.NPh.10.4.044303
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Significance: Two-photon (2p) microscopy has historically relied on titanium sapphire pulsed lasers that are expensive and have a large footprint. Recently, several manufacturers have developed less expensive compact pulsed lasers optimized for 2p excitation of green fluorophores. However, quantitative evaluation of their quality is lacking. Aim: We describe a simple approach to systematically evaluate 2p excitation efficiency, an empiric measure of the quality of a pulsed laser and its ability to elicit 2p induced fluorescence. Approach: By measuring pulse width, repetition rate, and fluorescence output, we calculated a measure of 2p excitation efficiency., which we compared for four commercially available compact pulsed lasers in the 920 to 930 nm wavelength range. Results: 2p excitation efficiency varied substantially among tested lasers. The Coherent Axon exhibited the best 2p excitation efficiency (1.09 similar to 0.03), exceeding that of a titanium sapphire reference laser (defined to have efficiency = 1). However, its measured fluorescence was modest due to its long pulse width. Of the compact lasers, the Toptica Femtofiber Ultra exhibited the best combination of measured fluorescence (0.75 similar to 0.01) and 2p excitation efficiency (0.86 similar to 0.01). Conclusions: We describe a simple method that both laser developers and end users can use to benchmark the 2p excitation efficiency of lasers used for 2p microscopy.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Diode-pumped lasers for two-photon fluorescence microscopy
    Univ of Strathclyde, Glasgow, United Kingdom
    Conf Proc Laser Electr Optic Soc Annu Meet, (103):
  • [42] Live-Cell Superresolution Imaging by Pulsed STED Two-Photon Excitation Microscopy
    Takasaki, Kevin T.
    Ding, Jun B.
    Sabatini, Bernardo L.
    BIOPHYSICAL JOURNAL, 2013, 104 (04) : 770 - 777
  • [43] THE TWO-PHOTON EXCITATION SPECTRUM OF PYRENE
    SALVI, PR
    FOGGI, P
    CASTELLUCCI, E
    CHEMICAL PHYSICS LETTERS, 1983, 98 (03) : 206 - 211
  • [44] Two-photon excitation of aluminium phthalocyanines
    Meshalkin, YP
    Alfimov, EE
    Vasil'ev, NE
    Denisov, AN
    Makukha, VK
    Ogirenko, AP
    QUANTUM ELECTRONICS, 1999, 29 (12) : 1066 - 1068
  • [45] Two-photon excitation of substituted enediynes
    Kauffman, JF
    Turner, JM
    Alabugin, IV
    Breiner, B
    Kovalenko, SV
    Badaeva, EA
    Masunov, A
    Tretiak, S
    JOURNAL OF PHYSICAL CHEMISTRY A, 2006, 110 (01): : 241 - 251
  • [46] Biphoton focusing for two-photon excitation
    Nasr, MB
    Abouraddy, AF
    Booth, MC
    Saleh, BEA
    Sergienko, AV
    Teich, MC
    Kempe, M
    Wolleschensky, R
    PHYSICAL REVIEW A, 2002, 65 (02): : 1 - 6
  • [47] Two-photon excitation of a phytofluor protein
    Gryczynski, I
    Piszczek, G
    Lakowicz, JR
    Lagarias, JC
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2002, 150 (1-3) : 13 - 19
  • [48] Two-photon excitation fluorescence bioassays
    Hanninen, Pekka
    Soukka, Jori
    Soini, Juhani T.
    FLUORESCENCE METHODS AND APPLICATIONS: SPECTROSCOPY, IMAGING, AND PROBES, 2008, 1130 : 320 - 326
  • [49] Lineshapes in coherent two-photon excitation
    Halfmann, T
    Rickes, T
    Vitanov, NV
    Bergmann, K
    OPTICS COMMUNICATIONS, 2003, 220 (4-6) : 353 - 359
  • [50] TWO-PHOTON EXCITATION IN PHENANTHRENE.
    Srivastava, G.P.
    Goyal, M.L.
    Shyam, Radhey
    Gupta, S.C.
    1972, 62 (06):