Axial Compressive Behaviours of Coal Gangue Concrete-Filled Circular Steel Tubular Stub Columns after Chloride Salt Corrosion

被引:1
|
作者
Zhang, Tong [1 ]
Wang, Hongshan [1 ]
Zheng, Xuanhe [1 ]
Gao, Shan [2 ]
机构
[1] Liaoning Tech Univ, Sch Civil Engn, Fuxin 123000, Peoples R China
[2] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150000, Peoples R China
关键词
coal gangue concrete-filled circular steel tube columns; chloride salt corrosion; axial compressive bearing capacity; ultimate bearing capacity design method; COARSE AGGREGATE; SUSTAINED LOAD;
D O I
10.3390/ma17112782
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The axial compressive behaviours of coal gangue concrete-filled steel tube (GCFST) columns after chloride salt corrosion were investigated numerically. Numerical modelling was conducted through the static analysis method by finite element (FE) analysis. The failure mechanism, residual strength, and axial load-displacement curves were validated against tests of the coal gangue aggregate concrete-filled steel tube (GCFST) columns at room and natural aggregate concrete-filled steel tube (NCFST) columns after salt corrosion circumstance. According to the analysis on the stress distribution of the steel tube, the stress value of the steel tube decreased as the corrosion rate increased at the same characteristic point. A parametric analysis was carried out to determine the effect of crucial variation on residual strength. It indicated that material strength, the steel ratio, and the corrosion rate made a profound impact on the residual strength from the FE. The residual strength of the columns exposed to chloride salt was in negative correlation with the corrosion rate. The impact on the residual strength of the column was little, obvious by the replacement rate of the coal gangue. A simplified design formula for predicting the ultimate strength of GCFST columns after chloride salt corrosion exposure was proposed.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Composite action of hollow concrete-filled circular steel tubular stub columns
    Fu, Qiang
    Ding, Fa-xing
    Zhang, Tao
    Wang, Liping
    Fang, Chang-jing
    STEEL AND COMPOSITE STRUCTURES, 2018, 26 (06): : 693 - 703
  • [22] Analysis on axial compressive bearing capacity of circular concrete-filled steel tubular stub columns with internal profiled steel under different steel ratio
    Mao W.-J.
    Shi Y.-L.
    Wang W.-D.
    Wang, Wen-Da (wangwd@lut.cn), 1600, Tsinghua University (34): : 63 - 70
  • [23] Compressive behaviour of tapered concrete-filled double skin steel tubular stub columns
    Deng, Ran
    Zhou, Xu-Hong
    Deng, Xiao-Wei
    Ke, Ke
    Bai, Jiu-Lin
    Wang, Yu-Hang
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2021, 184
  • [24] Compressive behaviour of tapered concrete-filled double skin steel tubular stub columns
    Deng, Ran
    Zhou, Xu-Hong
    Deng, Xiao-Wei
    Ke, Ke
    Bai, Jiu-Lin
    Wang, Yu-Hang
    Journal of Constructional Steel Research, 2021, 184
  • [25] FIRE RESISTANCE OF CONCRETE-FILLED CIRCULAR STEEL TUBULAR COLUMNS WITH INTERNAL PROFILED STEEL UNDER AXIAL COMPRESSIVE
    Mao, Wenjing
    Shi, Yanli
    Wang, Wenda
    Fundamental Research in Structural Engineering: Retrospective and Prospective, Vols 1 and 2, 2016, : 1211 - 1217
  • [26] Axial Compressive Behavior of Lithium Slag Recycled Coarse Aggregate Concrete-Filled Circular Steel Stub Columns
    Wang, Qiao-Huan
    Liang, Jiong-Feng
    He, Chun-Feng
    Li, Wei
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2022, 2022
  • [27] Axial compressive behaviours of concrete-filled square GFRP tubular columns at low temperatures
    Wang, Zhe
    Xie, Jian
    Wang, Meng-Qin
    Yan, Jia-Bao
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 359
  • [28] Hysteresis behaviours of circular steel reinforced concrete-filled stainless steel tubular columns
    Wang, Zhibin
    Huang, Shutian
    Peng, Guihan
    Lin, Wanfu
    Li, Xinlei
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2024, 45 (12): : 97 - 110
  • [29] Axial compressive behaviour of concrete-filled steel tubular columns with interfacial damage
    Qu, Xiushu
    Huang, Fei
    Sun, Guojun
    Liu, Qi
    Wang, Hui
    ADVANCES IN STRUCTURAL ENGINEERING, 2020, 23 (06) : 1224 - 1237
  • [30] Preliminary Analysis on Inclined Concrete-Filled Steel Tubular Stub Columns with Circular Section under Axial Compression
    Ren, Qingxin
    Lv, Yanbo
    Jia, Lianguang
    Liu, Deqing
    COMPUTER-AIDED DESIGN, MANUFACTURING, MODELING AND SIMULATION, PTS 1-2, 2011, 88-89 : 46 - 49