Longitudinal evaluation of RTVue optical coherence tomography in patients with glaucoma and suspected glaucoma and stable visual fields

被引:0
|
作者
Ribeiro Junior, Valdenir [1 ]
Avila, Marcos P. [1 ]
Ribeiro, Cristiane F. [1 ]
Magacho, Leopoldo [1 ,2 ]
机构
[1] Univ Fed Goias, Ophthalmol Dept, Goiania, Go, Brazil
[2] VER Hosp Olhos, Goiania, Go, Brazil
关键词
Imaging diagnosis/methods; Optical disk/pathology; Nervous fibers/pathology; Glaucoma/diagnosis; Tomography; optical coherence; FIBER LAYER LOSS; THICKNESS MEASUREMENT; MACULAR THICKNESS; PROGRESSION; MANIFEST; RATES;
D O I
10.5935/0004-2749.2021-0407
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To longitudinally compare isolated structural parameters obtained using RTVue optical coherence tomography in patients with glaucoma and suspected glaucoma with stable visual fields. Methods: All patients were required to have a reliable SITA Standard 24-2 Humphrey Visual Field test. Visual field stability was defined as having <5 points with p<5% and/or having no points with p<1% and/or p<0.05% in the glaucoma progression analysis comparison graph. Furthermore, the glaucoma assessment strategy was used in optical coherence tomography. Results: The study included 75 eyes from 75 patients, 43 of which had glaucoma and 32 had suspected glaucoma. The mean visual field intervals were 29.57 +/- 9.65 months between the first and third tests. No visual field parameter variations (mean deviation, pattern standard deviation, and visual field index) and no retinal nerve fiber layer or optic disk parameter variations between the first and third tests were observed (p>0.05 for all), and no retinal nerve fiber layer parameter variations throughout the study were observed, except for optic disk parameters presenting with cup volume changes (p=0.004). However, ganglion complex cells presented a progressively decreased average ganglion cell complex parameter, with a variability of -0.98% +/- 3.71% (p=0.04) between the first and third tests. By contrast, the global loss volume progressively increased throughout the study, with a variability of 14.71% +/- 44.52% (p=0.04) between the first and third tests. The inferior ganglion cell complex parameter was significantly decreased between the first and third tests (p=0.02). Conclusion: The present findings suggest that patients with glaucoma or suspected glaucoma with stable visual fields may present structural ganglion complex cell progression as assessed using RTVue optical coherence tomography.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Optical coherence tomography angiography in glaucoma
    Fard, Masoud Aghsaei
    Ritch, Robert
    ANNALS OF TRANSLATIONAL MEDICINE, 2020, 8 (18)
  • [22] Evaluation of clinical disc asymmetry in glaucoma with optical coherence tomography
    Giaconi, JA
    Nouri-Mahdave, K
    Law, SK
    Hoffman, D
    Caprioli, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U450 - U450
  • [23] Overhead Mounted Optical Coherence Tomography in Childhood Glaucoma Evaluation
    Go, Michelle S.
    Barman, Navajyoti R.
    Kelly, Michael P.
    House, Robert J.
    Rotruck, Jill C.
    El-Dairi, Mays A.
    Freedman, Sharon F.
    JOURNAL OF GLAUCOMA, 2020, 29 (09) : 742 - 749
  • [24] Comparison of Glaucoma Progression Detection by Optical Coherence Tomography and Visual Field
    Zhang, Xinbo
    Dastiridou, Anna
    Francis, Brian A.
    Tan, Ou
    Varma, Rohit
    Greenfield, David S.
    Schuman, Joel S.
    Huang, David
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 184 : 63 - 74
  • [25] Optical coherence tomography angiography and the visual field in hypertensive and normotensive glaucoma
    Zakova, Marketa
    Lestak, Jan
    Fus, Martin
    Maresova, Klara
    BIOMEDICAL PAPERS-OLOMOUC, 2021, 165 (04): : 441 - 444
  • [26] Comparison of Glaucoma Progression Detection by Optical Coherence Tomography and Visual Field
    Dastiridou, Anna
    Zhang, Xinbo
    Francis, Brian Alan
    Tan, Ou
    Varma, Rohit
    Greenfield, David S.
    Schuman, Joel S.
    Huang, David
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [27] Relation Between Structural Measurements by Spectral Domain Optical Coherence Tomography (RTVue-100) and Functional Parameters in Glaucoma Patients
    Tanga, L.
    Oddone, F.
    Manni, G.
    Lotito, S.
    Tranchina, L.
    Roberti, G.
    Michelessi, M.
    Fogagnolo, P.
    Centofanti, M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [28] Time to Glaucoma Progression Detection by Optical Coherence Tomography and Visual Field in Glaucoma Individuals of African Descent
    Wu, Jo-hsuan
    Moghimi, Sasan
    Walker, Evan
    Nishida, Takashi
    Liebmann, Jeffrey m.
    Fazio, Massimo a.
    Girkin, Christopher a.
    Zangwill, Linda m.
    Weinreb, Robert n.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2025, 269 : 195 - 204
  • [29] Accuracy of optical coherence tomography (OCT) in pachymetry for glaucoma patients
    Marcelo Ayala
    Robert Strandås
    BMC Ophthalmology, 15
  • [30] Accuracy of optical coherence tomography (OCT) in pachymetry for glaucoma patients
    Ayala, Marcelo
    Strandas, Robert
    BMC OPHTHALMOLOGY, 2015, 15