Influence of CAD/CAM Manufacturing Technique and Implant Abutment Angulation on Loosening of Individual Screw-Retained Implant Crowns

被引:0
|
作者
Rico-Coderch, Aitana [1 ]
Felix, Luis F. [2 ]
Sola-Ruiz, Maria Fernanda [1 ]
Medina, Michell [2 ]
Agustin-Panadero, Ruben [1 ]
Ortega, Rocio [3 ]
Cascos, Rocio [4 ]
Gomez-Polo, Miguel [4 ]
机构
[1] Univ Valencia, Fac Med & Dent, Dept Dent Med, Valencia 46010, Spain
[2] Autonomous Univ Sinaloa, Fac Dent, Dept Prosthet Dent, Culiacan Rosales 80040, Mexico
[3] European Univ Madrid, Sch Dent, Dept Prosthet Dent, Madrid 28045, Spain
[4] Univ Complutense Madrid, Fac Dent, Dept Prosthet Dent, Madrid 28040, Spain
关键词
screw loosening; implant single crowns; machined abutments; laser sintered; abutment angulation;
D O I
10.3390/met14070816
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Background: Dental implant abutment screw loosening is an increasingly common problem, as evidenced by multiple studies that have investigated its causes. The objective of this study was to compare the screw loosening torque values before and after cyclic loading and to determine whether they are affected by the CAD/CAM abutment manufacturing technique (machined or laser-sintered) and abutment angulation. Materials and Methods: Ninety implants were used and divided into two groups: 45 implants received machined abutments (group A) and 45 implants received laser-sintered abutments (group B). Each group was further divided into three subgroups, with 15 implants each, based on the abutment angulation involved (0 degrees, 15 degrees and 20 degrees). The abutments were tightened to the torque recommended by the manufacturer, and the reverse torque value was measured before and after cyclic loading (300,000 cycles). Data analysis was performed using one-way ANOVA and Wilcoxon signed-rank tests. Results: Statistically significant differences were observed between the laser-sintered and machined groups (p < 0.01). Additionally, differences were observed between subgroups with different angulations for both machined (16.2 +/- 1.75, 14.7 +/- 1.74 and 13.4 +/- 1.08 Ncm) and laser-sintered abutments (14.6 +/- 1.25, 12.7 +/- 1.2 and 11.1 +/- 1.35 Ncm) (0 degrees, 15 degrees and 20 degrees, respectively). Conclusions: The final screw loosening torque after cyclic loading was lower than the initial loosening torque. Both abutment angulation and the CAD/CAM manufacturing method exerted a statistically significant influence on the final loosening torque. The abutment angulation factor was estimated to have an influence of 34.5%, while the abutment manufacturing method was estimated to have an influence of 21%.<br />
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Fluids and microbial penetration in the internal part of cement-retained versus screw-retained implant-abutment connections
    Piattelli, A
    Scarano, A
    Paolantonio, M
    Assenza, B
    Leghissa, GC
    Di Bonaventura, G
    Catamo, G
    Piccolomini, R
    JOURNAL OF PERIODONTOLOGY, 2001, 72 (09) : 1146 - 1150
  • [32] Bacterial penetration in the internal part of cement-retained versus screw-retained implant-abutment connections.
    Di Labio, L
    Piattelli, A
    Assenza, B
    Leghissa, GC
    Scarano, A
    Paolantonio, M
    Piccolomini, R
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 213 - 213
  • [33] Marginal fit of cemented and screw-retained crowns incorporated onto the ITI® Dental Implant System.
    Brägger, U
    Tosches, N
    Flury, K
    Lang, NP
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 901 - 901
  • [34] Determination of fluid leakages in the different screw-retained implant-abutment connections in a mechanical artificial mouth
    D. Martin-Gili
    M. Molmeneu
    M. Fernandez
    M. Punset
    Ll. Giner
    J. Armengou
    F. Javier Gil
    Journal of Materials Science: Materials in Medicine, 2015, 26
  • [35] Mechanical Behavior and Fracture Loads of Screw-Retained and Cement-Retained Lithium Disilicate Implant-Supported Crowns
    Camatta, Hercules Pessin
    Ferreira, Rodrigo Melim
    Ferrairo, Brunna Mota
    Strelhow, Samira Sandy
    Rubo, Jose Henrique
    Mori, Aline Akemi
    Ferruzzi, Fernanda
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (08): : 690 - 697
  • [36] Determination of fluid leakages in the different screw-retained implant-abutment connections in a mechanical artificial mouth
    Martin-Gili, D.
    Molmeneu, M.
    Fernandez, M.
    Punset, M.
    Giner, Ll
    Armengou, J.
    Gil, F. Javier
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2015, 26 (07)
  • [37] Porcelain Fracture Resistance of Screw-Retained, Cement-Retained, and Screw-Cement-Retained Implant-Supported Metal Ceramic Posterior Crowns
    Al-Omari, Wael M.
    Shadid, Rola
    Abu-Naba'a, Layla
    El Masoud, Bilal
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2010, 19 (04): : 263 - 273
  • [38] Fracture Strength of Implant Screw-Retained All-Ceramic Crowns with the Use of the Angulated Screw Channel: A Pilot Study
    Drew, Alexander
    Randi, Anthony
    DiPede, Louis
    Luke, Allyn
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2020, 40 (02) : 245 - 252
  • [39] Procedure for obturating the access canal and preventing the loosening of the abutment screw in an implant-retained fixed prosthesis
    von Krammer, R
    JOURNAL OF PROSTHETIC DENTISTRY, 1999, 81 (02): : 234 - 236
  • [40] Digital vs Conventional Workflow for Screw-Retained Single-Implant Crowns: A Comparison of Key Considerations
    Di Fiore, Adolfo
    Vigolo, Paolo
    Graiff, Lorenzo
    Stellini, Edoardo
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2018, 31 (06) : 577 - 579