Influence of CAD/CAM Manufacturing Technique and Implant Abutment Angulation on Loosening of Individual Screw-Retained Implant Crowns

被引:0
|
作者
Rico-Coderch, Aitana [1 ]
Felix, Luis F. [2 ]
Sola-Ruiz, Maria Fernanda [1 ]
Medina, Michell [2 ]
Agustin-Panadero, Ruben [1 ]
Ortega, Rocio [3 ]
Cascos, Rocio [4 ]
Gomez-Polo, Miguel [4 ]
机构
[1] Univ Valencia, Fac Med & Dent, Dept Dent Med, Valencia 46010, Spain
[2] Autonomous Univ Sinaloa, Fac Dent, Dept Prosthet Dent, Culiacan Rosales 80040, Mexico
[3] European Univ Madrid, Sch Dent, Dept Prosthet Dent, Madrid 28045, Spain
[4] Univ Complutense Madrid, Fac Dent, Dept Prosthet Dent, Madrid 28040, Spain
关键词
screw loosening; implant single crowns; machined abutments; laser sintered; abutment angulation;
D O I
10.3390/met14070816
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Background: Dental implant abutment screw loosening is an increasingly common problem, as evidenced by multiple studies that have investigated its causes. The objective of this study was to compare the screw loosening torque values before and after cyclic loading and to determine whether they are affected by the CAD/CAM abutment manufacturing technique (machined or laser-sintered) and abutment angulation. Materials and Methods: Ninety implants were used and divided into two groups: 45 implants received machined abutments (group A) and 45 implants received laser-sintered abutments (group B). Each group was further divided into three subgroups, with 15 implants each, based on the abutment angulation involved (0 degrees, 15 degrees and 20 degrees). The abutments were tightened to the torque recommended by the manufacturer, and the reverse torque value was measured before and after cyclic loading (300,000 cycles). Data analysis was performed using one-way ANOVA and Wilcoxon signed-rank tests. Results: Statistically significant differences were observed between the laser-sintered and machined groups (p < 0.01). Additionally, differences were observed between subgroups with different angulations for both machined (16.2 +/- 1.75, 14.7 +/- 1.74 and 13.4 +/- 1.08 Ncm) and laser-sintered abutments (14.6 +/- 1.25, 12.7 +/- 1.2 and 11.1 +/- 1.35 Ncm) (0 degrees, 15 degrees and 20 degrees, respectively). Conclusions: The final screw loosening torque after cyclic loading was lower than the initial loosening torque. Both abutment angulation and the CAD/CAM manufacturing method exerted a statistically significant influence on the final loosening torque. The abutment angulation factor was estimated to have an influence of 34.5%, while the abutment manufacturing method was estimated to have an influence of 21%.<br />
引用
收藏
页数:13
相关论文
共 50 条
  • [1] A technique for recording the abutment screw angulation of cement-retained implant prostheses
    Lee, Ju-Hyoung
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (05): : 741 - 742
  • [2] A Technique for Repairing a Loosening Abutment Screw for a Cement-Retained Implant Prosthesis
    Patil, Pravinkumar G.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2011, 20 (08): : 652 - 655
  • [3] New abutment for a screw-retained, implant-supported crown
    Prisco, R
    Morgano, SM
    D'Amato, S
    JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (01): : 30 - 33
  • [4] A TECHNIQUE FOR FABRICATING SINGLE SCREW-RETAINED IMPLANT-SUPPORTED INTERIM CROWNS IN CONJUNCTION WITH IMPLANT SURGERY
    McRory, M. Eric
    Cagna, David R.
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 111 (06): : 455 - 459
  • [5] Prevention of bacterial leakage into screw-retained implant crowns in vitro
    Guindy, JS
    Besimo, CE
    Besimo, R
    Lewetag, D
    Meyer, J
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 122 - 122
  • [6] Influence of implant/abutment joint designs on abutment screw loosening in a dental implant system
    Kitagawa, T
    Tanimoto, Y
    Odaki, M
    Nemoto, K
    Aida, M
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 75B (02) : 457 - 463
  • [7] The influence of implant–abutment connection on the screw loosening and microleakage
    Katsuhiro Tsuruta
    Yasunori Ayukawa
    Tatsuya Matsuzaki
    Masafumi Kihara
    Kiyoshi Koyano
    International Journal of Implant Dentistry, 4
  • [8] The Effect of Screw Color and Technique to Fill Access Hole on the Final Color of Screw-Retained Implant Crowns
    Kurt, Murat
    Ural, Cagri
    Kulunk, Tolga
    Sanal, Ayse Fatma
    Erkocak, Ayca
    JOURNAL OF ORAL IMPLANTOLOGY, 2011, 37 (06) : 673 - 679
  • [9] The use of monolithic lithium disilicate for posterior screw-retained implant crowns
    Mobilio, Nicola
    Catapano, Santo
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (06): : 703 - 705
  • [10] Effect of abutment finish lines on the mechanical behavior and marginal fit of screw-retained implant crowns: An in vitro study
    Garcia-Gonzalez, Marta
    Gonzalez-Gonzalez, Ignacio
    Garcia-Garcia, Ismael
    Blason-Gonzalez, Sergio
    Lamela-Rey, Maria Jesus
    Fernandez-Canteli, Alfonso
    Alvarez-Arenal, Angel
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (02): : 318.e1 - 318.e10