Finite element analysis of patient-specific additive-manufactured implants

被引:0
|
作者
Namvar, Arman [1 ,2 ]
Lozanovski, Bill [1 ]
Downing, David [1 ]
Williamson, Tom [1 ,3 ]
Kastrati, Endri [1 ,3 ]
Shidid, Darpan [1 ]
Hill, David [1 ]
Buehner, Ulrich [3 ]
Ryan, Stewart [4 ]
Choong, Peter F. [2 ]
Sanaei, Reza [4 ]
Leary, Martin [1 ]
Brandt, Milan [1 ]
机构
[1] RMIT Univ, RMIT Ctr Addit Manufacture, Sch Engn, Melbourne, Vic, Australia
[2] St Vincents Hosp, Dept Surg, Melbourne, Vic, Australia
[3] Stryker, Sydney, NSW, Australia
[4] Univ Melbourne, Melbourne Vet Sch, Fac Sci, Melbourne, Vic, Australia
关键词
bone tumors; patient-specific implants; endoprosthetic reconstruction; biomechanical testing; additive manufacturing; femur; LATTICE STRUCTURES; STRENGTH;
D O I
10.3389/fbioe.2024.1386816
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Introduction: Bone tumors, characterized by diverse locations and shapes, often necessitate surgical excision followed by custom implant placement to facilitate targeted bone reconstruction. Leveraging additive manufacturing, patient-specific implants can be precisely tailored with complex geometries and desired stiffness, enhancing their suitability for bone ingrowth.Methods: In this work, a finite element model is employed to assess patient-specific lattice implants in femur bones. Our model is validated using experimental data obtained from an animal study (n = 9).Results: The results demonstrate the accuracy of the proposed finite element model in predicting the implant mechanical behavior. The model was used to investigate the influence of reducing the elastic modulus of a solid Ti6Al4V implant by tenfold, revealing that such a reduction had no significant impact on bone behavior under maximum compression and torsion loading. This finding suggests a potential avenue for reducing the endoprosthesis modulus without compromising bone integrity.Discussion: Our research suggests that employing fully lattice implants not only facilitates bone ingrowth but also has the potential to reduce overall implant stiffness. This reduction is crucial in preventing significant bone remodeling associated with stress shielding, a challenge often associated with the high stiffness of fully solid implants. The study highlights the mechanical benefits of utilizing lattice structures in implant design for enhanced patient outcomes.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Finite Element Analysis of Patient-Specific Mitral Valve with Mitral Regurgitation
    Thuy Pham
    Fanwei Kong
    Caitlin Martin
    Qian Wang
    Charles Primiano
    Raymond McKay
    John Elefteriades
    Wei Sun
    Cardiovascular Engineering and Technology, 2017, 8 : 3 - 16
  • [22] Patient-specific Finite Element Analysis of Fiber Post and Ferrule Design
    Rodrigues, Monise de Paula
    Ferreira Soares, Priscilla Barbosa
    Correia Miranda Valdivia, Andrea Dollores
    Pessoa, Roberto Sales
    Verissimo, Crisnicaw
    Versluis, Antheunis
    Soares, Carlos Jose
    JOURNAL OF ENDODONTICS, 2017, 43 (09) : 1539 - 1544
  • [23] Finite Element Analysis of Patient-Specific Femur Bone for Synthetic Biomaterials
    Khare, Navneet
    Sharma, Gorang
    Modi, Yashwant Kumar
    ADVANCES IN MECHANICAL ENGINEERING, ICRIDME 2018, 2020, : 649 - 659
  • [24] Advancing of Additive-Manufactured Titanium Implants with Bioinspired Micro- to Nanotopographies
    Maher, Shaheer
    Wijenayaka, Asiri R.
    Lima-Marques, Luis
    Yang, Dongqing
    Atkins, Gerald J.
    Losic, Dusan
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2021, 7 (02) : 441 - 450
  • [25] Numerical Method for the Design of Healing Chamber in Additive-Manufactured Dental Implants
    Lee, Hsiao-Chien
    Tsai, Pei-I
    Huang, Chih-Chieh
    Chen, San-Yuan
    Chao, Chuen-Guang
    Tsou, Nien-Ti
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [26] Finite Element Analysis of Patient-Specific Mitral Valve with Mitral Regurgitation
    Thuy Pham
    Kong, Fanwei
    Martin, Caitlin
    Wang, Qian
    Primiano, Charles
    McKay, Raymond
    Elefteriades, John
    Sun, Wei
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2017, 8 (01) : 3 - 16
  • [27] Anisotropic finite element modeling for patient-specific mandible
    Liao, Sheng-Hui
    Tong, Ruo-Feng
    Dong, Jin-Xiang
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2007, 88 (03) : 197 - 209
  • [28] An additively manufactured locking fixation system for potential application in patient-specific implants
    Fischer, Ralf D.
    Klasen, Jan
    Shmatok, Andrii
    Prorok, Barton C.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 124 (124)
  • [29] Fabrication, characterisation, and finite element analysis of cold metal transfer-based wire and arc additive-manufactured aluminium alloy
    Pramod, R.
    Mohan Kumar, S.
    Girinath, B.
    Rajesh Kannanc, A.
    Pravin Kumar, N.
    Siva Shanmugam, N.
    Rivista Italiana della Saldatura, 2021, 73 (03): : 331 - 350
  • [30] Finite Element Analysis of Patient-Specific Condyle Fracture Plates: A Preliminary Study
    Aquilina, Peter
    Parr, William C. H.
    Chamoli, Uphar
    Wroe, Stephen
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2015, 8 (02) : 111 - 116