COMBINED HEAT AND POWER SUPPLY DEMONSTRATION OF MICRO-MIX HYDROGEN COMBUSTION APPLIED TO M1A-17 GAS TURBINE

被引:0
|
作者
Horikawa, Atsushi [1 ]
Ashikaga, Mitsugu [1 ]
Yamaguchi, Masato [1 ]
Ogino, Tomoyuki [1 ]
Aoki, Shigeki [1 ]
Wirsum, Manfred [2 ]
Funke, Harald H. -W. [3 ]
Kusterer, Karsten [4 ]
机构
[1] Kawasaki Heavy Ind Co Ltd, Kobe, Hyogo, Japan
[2] Rhein Westfal TH Aachen, Aachen, Germany
[3] Aachen Univ Appl Sci, Aachen, Germany
[4] B&B AGEMA GmbH, Aachen, Germany
关键词
Industrial Gas Turbine; Combustor development; Fuels; Hydrogen; Emission;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Kawasaki Heavy Industries, Ltd. (KHI), Aachen University of Applied Sciences, and B&B-AGEMA GmbH have investigated the potential of low NOx micro-mix (MMX) hydrogen combustion and its application to an industrial gas turbine combustor. Engine demonstration tests of a MMX combustor for the M1A-17 gas turbine with a co-generation system were conducted in the hydrogen-fueled power generation plant in Kobe City, Japan. This paper presents the results of the commissioning test and the combined heat and power (CHP) supply demonstration. In the commissioning test, grid interconnection, loading tests and load cut-off tests were successfully conducted. All measurement results satisfied the Japanese environmental regulation values. Dust and soot as well as SOx were not detected. The NOx emissions were below 84 ppmv at 15 % O-2. The noise level at the site boundary was below 60 dB. The vibration at the site boundary was below 45 dB. During the combined heat and power supply demonstration, heat and power were supplied to neighboring public facilities with the MMX combustion technology and 100 % hydrogen fuel. The electric power output reached 1800 kW at which the NOx emissions were 72 ppmv at 15 % O-2, and 60 %RH. Combustion instabilities were not observed. The gas turbine efficiency was improved by about 1 % compared to a non-premixed type combustor with water injection as NOx reduction method. During a total equivalent operation time of 1040 hours, all combustor parts, the M1A-17 gas turbine as such, and the co-generation system were without any issues.
引用
收藏
页数:7
相关论文
共 46 条
  • [21] HYDROGEN CO-FIRING DEMONSTRATION AT GEORGIA POWER'S PLANT MCDONOUGH: M501G GAS TURBINE
    Harper, Jim
    Cloyd, Scott
    Pigon, Travis
    Thomas, Benjamin
    Wilson, Jeff
    Johnson, Eric
    Noble, David R.
    PROCEEDINGS OF ASME TURBO EXPO 2023: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2023, VOL 6, 2023,
  • [22] Effect of oxygen supply method on the performance of a micro gas turbine-based triple combined cycle with oxy-combustion carbon capture
    Ahn, Ji Ho
    Kim, Tong Seop
    ENERGY, 2020, 211
  • [23] Optimization of Hydrogen Gas Turbine Power Supply by means of a novel Modular Multilevel Parallel Converter (M2PC)
    Helling, Florian
    Singer, Arthur
    Goetz, Stefan
    Weyh, Thomas
    2014 5TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2014,
  • [24] Reducing waste heat to the minimum: Thermodynamic assessment of the M-power cycle concept applied to micro Gas Turbines
    De Paepe, Ward
    Pappa, Alessio
    Carrero, Marina Montero
    Bricteux, Laurent
    Contino, Francesco
    APPLIED ENERGY, 2020, 279
  • [25] An ultra-high efficient micro combined heat and power cogeneration system based on gas combustion powered thermoelectric generator
    Li, Guoneng
    Zhang, Xinwei
    Zheng, Youqu
    Guo, Wenwen
    Tang, Yuanjun
    Ye, Chao
    APPLIED THERMAL ENGINEERING, 2023, 222
  • [26] COMBINED POWER-STATION - VARIANT HEAT EXTRACTION FROM THE GAS-TURBINE COMBUSTION-CHAMBER BY STEAM-GENERATION
    KESEL, W
    BRENNSTOFF-WARME-KRAFT, 1995, 47 (7-8): : 294 - &
  • [27] MODEL-BASED ANALYSIS OF A COMBINED HEAT AND POWER SYSTEM FEATURING A HYDROGEN-FIRED GAS TURBINE WITH ON-SITE HYDROGEN PRODUCTION AND STORAGE
    Bexten, Thomas
    Wirsum, Manfred
    Roscher, Bjoern
    Schelenz, Ralf
    Jacobs, Georg
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, VOL 5, PT II, 2020,
  • [28] Model-Based Analysis of a Combined Heat and Power System Featuring a Hydrogen-Fired Gas Turbine With On-Site Hydrogen Production and Storage
    Bexten, Thomas
    Wirsum, Manfred
    Roscher, Bjoern
    Schelenz, Ralf
    Jacobs, Georg
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2021, 143 (08):
  • [29] Integrating biomass gasification with a steam-injected micro gas turbine and an Organic Rankine Cycle unit for combined heat and power production
    Moradi, Ramin
    Marcantonio, Vera
    Cioccolanti, Luca
    Bocci, Enrico
    ENERGY CONVERSION AND MANAGEMENT, 2020, 205
  • [30] Thermoeconomic and exergoenvironmental assessments of a combined micro-gas turbine and superheated Kalina cycles for cogeneration of heat and electrical power using biomass
    Z. Liu
    M. A. Ehyaei
    International Journal of Environmental Science and Technology, 2022, 19 : 11233 - 11248