Performance-based fire assessment of a fully automated multi-storey steel parking structure: A computational approach

被引:0
|
作者
Mostofi, Sara [1 ]
Baltaci, Alihan [1 ]
Akbulut, Yunus Emrahan [1 ]
Okur, Fatih Yesevi [1 ,2 ]
Altunisik, Ahmet Can [1 ,2 ,3 ]
机构
[1] Karadeniz Tech Univ, Dept Civil Engn, TR-61080 Trabzon, Turkiye
[2] Karadeniz Tech Univ, Earthquake & Struct Hlth Monitoring Res Ctr, Trabzon, Turkiye
[3] Construct Ind Trade Co Ltd Sti, Dynam Acad Software, TR-61080 Trabzon, Turkiye
关键词
Steel; Parking structure; Fire; Performance -based assessment; FDS; OpenSees; CAR PARKS; SMOKE; SIMULATION; DESIGN; SCALE; RISK;
D O I
10.1016/j.csite.2024.104618
中图分类号
O414.1 [热力学];
学科分类号
摘要
Conducting a structural fire analysis for automated steel parking structures present a complex challenge due to the vulnerability of steel structures to high-temperature exposure, the unpredictability of fire source locations, and the enhanced thermal loading due to high concentration of vehicles in a compact area. This study conducted a performance-based assessment (PBA) of a fully automated multi-storey steel parking structure under various fire scenarios. The assessment employed Fire Dynamic Simulator (FDS) to simulate the fire behavior in different scenarios and record the temperature developments within the structure. OpenSees was utilized to perform the subsequent thermo-mechanical analysis and obtain the fire responses of the parking structure. The fire analyses demonstrated that the ignition location and ventilation conditions within the structure considerably affects fire propagation and structural responses. Fire cases initiated on the first floor led to a slightly higher drift ratio than those initiated on the 9th floor. The PBA based on strain and drift ratio led to different results. Cases 1, 2, 4, and 6 maintained life safety based on drift ratios, and strain results indicated a collapse prevention level. For centrally located fire cases, the drift ratios were at collapse prevention level while based on strain values, the elements already exceeded the collapse prevention limit. Under all fire cases, the ultimate performance level of the structure has exceeded the collapse prevention level. The findings highlight the necessity of employing fire safety measures in multi-storey parking structures and enhancing their fire resilience.
引用
收藏
页数:23
相关论文
共 34 条
  • [31] Assessment of the Molecular Expression and Structure of Gangliosides in Brain Metastasis of Lung Adenocarcinoma by an Advanced Approach Based on Fully Automated Chip-Nanoelectrospray Mass Spectrometry
    Zamfir, Alina D.
    Serb, Alina
    Vukelic, Zeljka
    Flangea, Corina
    Schiopu, Catalin
    Fabris, Dragana
    Kalanj-Bognar, Svjetlana
    Capitan, Florina
    Sisu, Eugen
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2011, 22 (12) : 2145 - 2159
  • [32] Performance-based global reliability assessment of a high-rise frame-core tube structure subjected to multi-dimensional stochastic earthquakes
    Liu Zhangjun
    Ruan Xinxin
    Liu Zixin
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2022, 21 (02) : 395 - 415
  • [33] Performance-based global reliability assessment of a high-rise frame-core tube structure subjected to multi-dimensional stochastic earthquakes
    Liu Zhangjun
    Ruan Xinxin
    Liu Zixin
    Earthquake Engineering and Engineering Vibration, 2022, 21 : 395 - 415
  • [34] Performance-based global reliability assessment of a high-rise frame-core tube structure subjected to multi-dimensional stochastic earthquakes
    Liu Zhangjun
    Ruan Xinxin
    Liu Zixin
    EarthquakeEngineeringandEngineeringVibration, 2022, 21 (02) : 395 - 415