Performance-based fire assessment of a fully automated multi-storey steel parking structure: A computational approach

被引:0
|
作者
Mostofi, Sara [1 ]
Baltaci, Alihan [1 ]
Akbulut, Yunus Emrahan [1 ]
Okur, Fatih Yesevi [1 ,2 ]
Altunisik, Ahmet Can [1 ,2 ,3 ]
机构
[1] Karadeniz Tech Univ, Dept Civil Engn, TR-61080 Trabzon, Turkiye
[2] Karadeniz Tech Univ, Earthquake & Struct Hlth Monitoring Res Ctr, Trabzon, Turkiye
[3] Construct Ind Trade Co Ltd Sti, Dynam Acad Software, TR-61080 Trabzon, Turkiye
关键词
Steel; Parking structure; Fire; Performance -based assessment; FDS; OpenSees; CAR PARKS; SMOKE; SIMULATION; DESIGN; SCALE; RISK;
D O I
10.1016/j.csite.2024.104618
中图分类号
O414.1 [热力学];
学科分类号
摘要
Conducting a structural fire analysis for automated steel parking structures present a complex challenge due to the vulnerability of steel structures to high-temperature exposure, the unpredictability of fire source locations, and the enhanced thermal loading due to high concentration of vehicles in a compact area. This study conducted a performance-based assessment (PBA) of a fully automated multi-storey steel parking structure under various fire scenarios. The assessment employed Fire Dynamic Simulator (FDS) to simulate the fire behavior in different scenarios and record the temperature developments within the structure. OpenSees was utilized to perform the subsequent thermo-mechanical analysis and obtain the fire responses of the parking structure. The fire analyses demonstrated that the ignition location and ventilation conditions within the structure considerably affects fire propagation and structural responses. Fire cases initiated on the first floor led to a slightly higher drift ratio than those initiated on the 9th floor. The PBA based on strain and drift ratio led to different results. Cases 1, 2, 4, and 6 maintained life safety based on drift ratios, and strain results indicated a collapse prevention level. For centrally located fire cases, the drift ratios were at collapse prevention level while based on strain values, the elements already exceeded the collapse prevention limit. Under all fire cases, the ultimate performance level of the structure has exceeded the collapse prevention level. The findings highlight the necessity of employing fire safety measures in multi-storey parking structures and enhancing their fire resilience.
引用
收藏
页数:23
相关论文
共 34 条
  • [1] The performance in fire of restrained steel columns in multi-storey construction
    Shepherd, PG
    Burgess, IW
    Plank, RJ
    O'Connor, DJ
    STRUCTURES IN THE NEW MILLENNIUM, 1997, : 333 - 340
  • [2] Performance-based and damage assessment of SFRP retrofitted multi-storey timber buildings
    Vahedian, Abbas
    Mahini, Seyed Saeed
    Glencross-Grant, Rex
    STRUCTURAL MONITORING AND MAINTENANCE, 2015, 2 (03): : 269 - 282
  • [3] Prediction and assessment of automated lifting system performance for multi-storey parking lots powered by solar energy
    Elhenawy, Y.
    Hafez, G.
    Abdel-Hamid, S.
    Elbany, Marwa
    JOURNAL OF CLEANER PRODUCTION, 2020, 266
  • [4] Performance based design approach for multi-storey concentrically braced steel frames
    Salawdeh, Suhaib
    Goggins, Jamie
    STEEL AND COMPOSITE STRUCTURES, 2016, 20 (04): : 749 - 776
  • [5] Evaluation of residual drift demands in regular multi-storey frames for performance-based seismic assessment
    Ruiz-Garcia, Jorge
    Miranda, Eduardo
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2006, 35 (13): : 1609 - 1629
  • [6] Performance-based seismic design and assessment of multi-storey CFS strap-braced frames
    Papargyriou, Ioannis
    Hajirasouliha, Iman
    ENGINEERING STRUCTURES, 2022, 261
  • [7] Vulnerability of asymmetric multi-storey buildings in the context of performance-based seismic design
    Hentri, Mohammed
    Hemsas, Miloud
    Nedjar, Djamel
    EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING, 2021, 25 (05) : 813 - 834
  • [8] Computational analysis of thermal and structural failure criteria of a multi-storey steel frame exposed to fire
    Rackauskaite, Egle
    Kotsovinos, Panagiotis
    Jeffers, Ann
    Rein, Guillermo
    ENGINEERING STRUCTURES, 2019, 180 : 524 - 543
  • [9] Research on performance-based seismic design of light-gauge steel framed system for multi-storey residences
    Dong, J
    Zhang, XJ
    Xia, BT
    PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON EARTHQUAKE ENGINEERING: NEW FRONTIER AND RESEARCH TRANSFORMATION, 2004, : 550 - 555
  • [10] Investigation of the Effects of Sprinkler System in Automated Vehicle Parking Structures Using Performance-Based Fire Assessment
    Altunisik, Ahmet Can
    Mostofi, Sara
    Baltaci, Alihan
    Akbulut, Yunus Emrahan
    Okur, Fatih Yesevi
    FIRE TECHNOLOGY, 2025, 61 (02) : 681 - 708