Microwave-Based State Diagnosis of Three-Way Catalysts: Impact Factors and Application Recommendations

被引:0
|
作者
Steiner, Carsten [1 ]
Malashchuk, Vladimir [1 ]
Kubinski, David [2 ]
Hagen, Gunter [1 ]
Moos, Ralf [1 ]
机构
[1] Univ Bayreuth, Bayreuth Engine Res Ctr BERC, Dept Funct Mat, D-95447 Bayreuth, Germany
[2] Ford Motor Co, Dearborn, MI 48124 USA
关键词
ceria; oxygen storage capacity (OSC); three-way catalyst (TWC); exhaust gas aftertreatment; microwave cavity perturbation; gasoline engine; on-board diagnosis (OBD); METAL-SUPPORT INTERACTION; OXYGEN STORAGE; CAVITY PERTURBATION; DEFECT STRUCTURE; OXIDATION-STATE; ELECTRICAL-CONDUCTIVITY; CERIA; MODEL; CEO2; NONSTOICHIOMETRY;
D O I
10.3390/s24134091
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study reassesses an overview of the potential of the radio frequency (RF)-based state diagnostics of three-way catalysts (TWC) based on a previous study with an emphasis on the defect chemistry of the catalyst material during reoxidation and reduction. Some data are based on the previous works but are newly processed, and the signal parameters resonant frequency and inverse quality factor are evaluated with respect to applicability. The RF-based method uses electromagnetic resonances in a cavity resonator to provide information on the storage level of the oxygen storage component. The analysis focuses on a holistic investigation and evaluation of the major effects influencing the RF signal during operation. On the one hand, the response to the oxygen storage behavior and the resolution of the measurement method are considered. Therefore, this study merges original data from multiple former publications to provide a comprehensive insight into important measurement effects and their defect chemistry background. On the other hand, the most important cross-sensitivities are discussed and their impact during operation is evaluated. Additionally, the effect of catalyst aging is analyzed. The effects are presented separately for the two resonant parameters: resonant frequency and (unloaded) quality factor. Overall, the data suggest that the quality factor has a way higher signal quality at low temperatures (<400 degrees C) and the resonant frequency is primarily suitable for high operating temperatures. At most operating points, the quality factor is even more robust against interferences such as exhaust gas stoichiometry and water content. Correctly estimating the catalyst temperature is the most important factor for reliable results, which can be achieved by combining the information of both resonant signals. In the end, the data indicate that microwave-based state diagnosis is a powerful system for evaluating the oxygen storage level over the entire operating range of a TWC. As a research tool and in its application, the system can therefore contribute to the improvement of the emission control of future gasoline vehicles.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] A three-way decision method in a hybrid decision information system and its application in medical diagnosis
    Li, Zhaowen
    Xie, Ningxin
    Huang, Dan
    Zhang, Gangqiang
    ARTIFICIAL INTELLIGENCE REVIEW, 2020, 53 (07) : 4707 - 4736
  • [32] ZrxTixAl1-2xO2 mixed oxide:: Preparation and application in three-way catalysts
    Yu Yao
    Gong Mao-Chu
    Guo Jia-Xiu
    Lin Tao
    Yuan Shu-Hua
    Chen Yao-Qiang
    CHINESE JOURNAL OF INORGANIC CHEMISTRY, 2007, 23 (08) : 1453 - 1456
  • [33] Impact of sulfur on three-way catalysts: Comparison of commercially produced Pd and Pt-Rh monoliths
    Beck, DD
    Sommers, JW
    CATALYSIS AND AUTOMOTIVE POLLUTION CONTROL III, 1995, 96 : 721 - 748
  • [34] A three-way decision method in a hybrid decision information system and its application in medical diagnosis
    Zhaowen Li
    Ningxin Xie
    Dan Huang
    Gangqiang Zhang
    Artificial Intelligence Review, 2020, 53 : 4707 - 4736
  • [35] An experimental and kinetic modeling study of aging impact on surface and subsurface oxygen storage in three-way catalysts
    Gong, Jian
    Wang, Di
    Li, Junhui
    Kamasamudram, Krishna
    Currier, Neal
    Yezerets, Aleksey
    CATALYSIS TODAY, 2019, 320 : 51 - 60
  • [36] A Method for Model-based On-board Diagnosis for Three-Way Catalytic Converters
    Fessler, Dirk K.
    Krebs, Volker
    AT-AUTOMATISIERUNGSTECHNIK, 2009, 57 (01) : 32 - 39
  • [37] Study on three-way catalyst deterioration diagnosis based on oxygen storage rate model
    Wang, D.-L. (wdbright@163.com), 1600, Chinese Society for Internal Combustion Engines, 92 Weijin Road, Tianjin, Meng Qing, 300072, China (34):
  • [38] A Recurrent Neural Networks based Method for Fault Diagnosis of Three-way Catalytic Converter
    Li, Penghua
    Wang, Guan
    Zheng, Mingyao
    Wang, Huan
    PROCEEDINGS OF THE 2019 31ST CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2019), 2019, : 3309 - 3313
  • [39] SI-Engine Control With Microwave-Assisted Direct Observation of Oxygen Storage Level in Three-Way Catalysts
    Schoedel, Sebastian
    Moos, Ralf
    Votsmeier, Martin
    Fischerauer, Gerhard
    IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2014, 22 (06) : 2346 - 2353
  • [40] Impact of Oxygen Storage Components in Prototype Pd-Based Three-Way Catalysts under Exhaust Conditions Relevant to Propane Engines
    Kim, Daekun
    Toops, Todd J.
    Nguyen, Ke
    Lance, Michael J.
    CATALYSTS, 2023, 13 (12)