A Novel X-Ray 3D Histological Method for Paraffinated Prostate Samples

被引:1
|
作者
Laguna-Castro, Santiago [1 ,2 ]
Tolonen, Teemu [3 ]
Mphande, Brian [4 ]
Hyttinen, Jari [1 ,2 ]
Kaipia, Antti [5 ]
机构
[1] Tampere Univ, Computat Biophys & Imaging Grp, Fac Med & Hlth Technol, Tampere 33520, Finland
[2] Tampere Univ, Fac Med & Hlth Technol, BioMediTech Unit, Tampere 33520, Finland
[3] Fimlab Labs, Dept Pathol, Tampere 33520, Finland
[4] Tampere Univ, Fac Med & Hlth Technol, Preclin Facil, Tampere 33520, Finland
[5] Tampere Univ Hosp, Dept Surg, Tampere 33520, Finland
来源
关键词
Cancer; Eosin; Micro-CT; Paraffin clearance;
D O I
10.1007/978-3-031-49062-0_27
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Prostate cancer grading currently relies on the histopathological assessment of biopsies, which are analyzed as histological slides. However, the inherent two-dimensional (2D) nature of this approach, along with the limited number of slices available for clinical analysis, increases the risk of underestimating cancerous lesions. We propose that non-destructive 3D imaging methods, such as micro-Computed Tomography, can provide a more realistic and accurate means for rapid and precise characterization of prostate malignancies, thereby minimizing diagnostic discrepancies in complex cases. In this study, we focused on the technical development of an advanced 3D X-ray micro-computed tomography method (micro-CT) for imaging formalin-fixed paraffin-embedded (FFPE) rat prostate samples. This method combines a novel paraffin-clearance protocol, the use of eosin as a contrast agent, and micro-CT imaging, followed by standard hematoxylin and eosin histology. The micro-CT imaging produced a 3D model that enabled visualization and segmentation of the prostate into two well-differentiated regions: epithelium plus stroma and lumen. The CT scan was validated with hematoxylin and eosin histology. The 3D images provided volume and area measurements from the segmented parts and displayed in fine detail the extension and continuation of the glandular luminal phase. The tissue integrity was well preserved during the process, making our protocol potentially compatible with further analytical techniques. The success of this initial approach to 3D imaging the rat prostate paves the way for the application of our method to clinical samples.
引用
收藏
页码:252 / 262
页数:11
相关论文
共 50 条
  • [11] 3D x-ray angiography
    Hoffmann, K
    MEDICAL PHYSICS, 2002, 29 (06) : 1278 - 1278
  • [12] A novel 3D printed radial collimator for x-ray diffraction
    Kowarik, S.
    Bogula, L.
    Boitano, S.
    Carla, F.
    Pithan, H.
    Schaefer, P.
    Wilming, H.
    Zykov, A.
    Pithan, L.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (03):
  • [13] Bayesian inversion method for 3D dental X-ray imaging
    Kolehmainen, V.
    Vanne, A.
    Siltanen, S.
    Järvenpää, S.
    Kaipio, J.P.
    Lassas, M.
    Kalke, M.
    Elektrotechnik und Informationstechnik, 2007, 124 (7-8): : 248 - 253
  • [14] Automatic thresholding method for 3D X-ray microtomography analysis
    Sales, E.
    Pereira, W. C. A.
    Gomez, W.
    Lima, I.
    Lopes, R. T.
    COMPUTATIONAL VISION AND MEDICAL IMAGE PROCESSING IV, 2014, : 409 - 414
  • [15] 3D X-ray based Method for Diagnostics of Spinal Deformities
    Shuts, Simon A.
    Fridman, Kirill M.
    Shuts, Boris S.
    Bootilski, Andrey N.
    Peshkova, Ellina, I
    REVISTA GEINTEC-GESTAO INOVACAO E TECNOLOGIAS, 2021, 11 (02): : 162 - 173
  • [16] 3D X-RAY IMAGE COMPOSITION
    Armeanu, Constantin Catalin
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN-SERIES A-APPLIED MATHEMATICS AND PHYSICS, 2016, 78 (01): : 309 - 320
  • [17] Multiscale 3D X-ray imaging
    R. Joseph Kline
    Nature Electronics, 2019, 2 : 435 - 436
  • [18] X-ray holography: Atoms in 3D
    Tegze, M.
    Faigel, G.
    Bortel, G.
    Marchesini, S.
    Belakhovsky, M.
    Simionovici, A.
    Journal of Alloys and Compounds, 2005, 401 (1-2): : 92 - 98
  • [19] 3D discrete X-ray transform
    Averbuch, A
    Shkolnisky, Y
    APPLIED AND COMPUTATIONAL HARMONIC ANALYSIS, 2004, 17 (03) : 259 - 276
  • [20] 3D X-ray crystal microscope
    Ice, GE
    Larson, BC
    ADVANCED ENGINEERING MATERIALS, 2000, 2 (10) : 643 - 646