Vector analysis of corneal astigmatism in cataractous eyes based on IOLMaster 700 biometry

被引:0
|
作者
Langenbucher, Achim [1 ]
Wendelstein, Jascha [1 ,2 ]
Cayless, Alan [3 ]
Hoffmann, Peter [4 ]
Szentmary, Nora [5 ,6 ]
机构
[1] Saarland Univ, Dept Expt Ophthalmol, Homburg, Germany
[2] Johannes Kepler Univ Linz, Dept Ophthalmol, Linz, Austria
[3] Open Univ, Sch Phys Sci, Milton Keynes, England
[4] Augen & Laserklin Castrop Rauxel, Castrop Rauxel, Germany
[5] Saarland Univ, Dr Rolf M Schwiete Ctr Limbal Stem Cell & Aniridia, Homburg, Germany
[6] Semmelweis Univ, Dept Ophthalmol, Budapest, Hungary
来源
PLOS ONE | 2024年 / 19卷 / 04期
关键词
MULTIVARIATE; TESTS;
D O I
10.1371/journal.pone.0300576
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose The purpose of this study was to investigate the effect of the corneal back surface by comparing the keratometric astigmatism (K, derived from the corneal front surface) of a modern optical biometer against astigmatism of Total Keratometry (TK, derived from both corneal surfaces) in a large population with cataractous eyes. The results were then used to define linear prediction models to map K to TK.Methods From a large dataset containing bilateral biometric measurements (IOLMaster 700) in 9736 patients prior to cataract surgery, the total corneal astigmatism was decomposed into vectors for K, corneal back surface (BS), and TK. A multivariate prediction model (MV), simplified model with separation of vector components (SM) and a constant model (CM) were defined to map K to TK vector components.Results The K centroid (X/Y) showed some astigmatism with-the-rule (0.1981/-0.0211 dioptre (dpt)) whereas the TK centroid was located around zero (-0.0071/-0.0381 dpt against-the-rule) and the BS centroid showed systematic astigmatism against-the-rule (-0.2367/-0.0145 dpt). The respective TK-K centroid was located at -0.2052/-0.0302 dpt. The MV model showed the same performance (i.e. mean absolute residuum) as the SM did (0.1098 and 0.1099 dpt respectively) while the CM performed only slightly worse (0.1121 dpt mean absolute residuum).Conclusion In cases where tomographic data are unavailable statistical models could be used to consider the overall contribution of the back surface to the total corneal astigmatism. Since the performance of the CM is sufficiently close to that of MV and SM we recommend using the CM which can be directly considered e.g. as surgically induced astigmatism.
引用
收藏
页数:14
相关论文
共 36 条
  • [21] Corneal and refractive error astigmatism in Singaporean schoolchildren: a vector-based Java']Javal's rule
    Tong, L
    Carkeet, A
    Saw, SM
    Tan, DTH
    OPTOMETRY AND VISION SCIENCE, 2001, 78 (12) : 881 - 887
  • [22] To compare central corneal thickness measurements obtained by Pentacam with those obtained by IOLMaster 700, Cirrus anterior segment optical coherence tomography and Tomey specular microscopy in normal healthy eyes
    Kumar, Kiran K.
    Prakash, Akshata A.
    Neeraja, T. G.
    Adappa, Karishma T.
    Prabha, Chandra T. S.
    Gangasagara, Suresh Babu
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2021, 69 (07) : 1713 - 1717
  • [23] Vector analysis of changes in corneal astigmatism following lateral tarsal strip procedure in patients with involutional ectropion or entropion
    Bahram Eshraghi
    Mansoureh Jamshidian-Tehrani
    Kaveh Fadakar
    Hossein Ali-Zamani
    Zahra Fallah Tafti
    Reza Ghaffari
    International Ophthalmology, 2019, 39 : 1679 - 1685
  • [24] Vector analysis of changes in corneal astigmatism following lateral tarsal strip procedure in patients with involutional ectropion or entropion
    Eshraghi, Bahram
    Jamshidian-Tehrani, Mansoureh
    Fadakar, Kaveh
    Ali-Zamani, Hossein
    Tafti, Zahra Fallah
    Ghaffari, Reza
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (08) : 1679 - 1685
  • [25] Power Vector Analysis of Refractive and Corneal Astigmatism Components, and Their Time-dependent Change: The Funagata Study.
    Namba, Hiroyuki
    Kawasaki, Ryo
    Narumi, Mari
    Sugano, Akira
    Homma, Kei
    Nishi, Katsuhiro
    Kato, Takeo
    Kayama, Takamasa
    Yamashita, Hidetoshi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [26] Keratometry versus total corneal refractive power: Analysis of measurement repeatability with 5 different devices in normal eyes with low astigmatism
    Fityo, Sylvia
    Buehren, Jens
    Shajari, Mehdi
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (04): : 569 - 576
  • [27] Air-puff induced corneal dynamics in normal, forme fruste and keratoconic eyes measured with OCT-based optical biometry
    Mlyniuk, Patryk
    Maczynska-Walkowiak, Ewa
    Rzeszewska-Zamiara, Jagoda
    Jimenez-Villar, Alfonso
    Kaluzny, Bartlomiej J.
    Grulkowski, Ireneusz
    OPTICS AND LASERS IN ENGINEERING, 2024, 176
  • [28] Pentacam and vector analysis to evaluate longitudinal corneal tomographical changes in non-progressive keratoconus eyes
    De Bernardo, Maddalena
    Abbinante, Giulia
    Vitiello, Livio
    Rosa, Nicola
    CONTACT LENS & ANTERIOR EYE, 2019, 42 (02): : 232 - 232
  • [29] Scheimpflug-Based Corneal Biomechanical Analysis As A Predictor of Glaucoma in Eyes With High Myopia
    Baptista, Pedro M. L.
    Ferreira, Andre S.
    Silva, Nisa P.
    Figueiredo, Ana R. M.
    Sampaio, Isabel C.
    Reis, Rita V. F.
    Ambrosio Jr, Renato
    Meneres, Pedro M. A. M.
    Beirao, Joao N. M.
    Meneres, Maria J. F. S.
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 545 - 563
  • [30] Evaluation of customized ablation based on corneal wavefront analysis for myopic corrections in virgin eyes
    Ren, Q
    Zhou, C
    Jin, M
    Wang, X
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46