Identification potential biomarkers for diagnosis, and progress of breast cancer by using high-pressure photon ionization time-of-flight mass spectrometry

被引:1
|
作者
Zhang, Jiao [1 ,2 ]
He, Xixi [1 ,2 ]
Guo, Xuhui [1 ,2 ]
Wang, Jia [1 ,2 ]
Gong, Xilong [1 ,2 ]
Jiao, Dechuang [1 ,2 ]
Chen, Haibin [3 ]
Liu, Zhenzhen [1 ,2 ]
机构
[1] Zhengzhou Univ, Affiliated Canc Hosp, Henan Breast Canc Ctr, Dept Breast Dis, Zhengzhou 450008, Peoples R China
[2] Henan Canc Hosp, Zhengzhou 450008, Peoples R China
[3] PCAB Res Ctr Breath & Metab, Breax Lab, Beijing, Peoples R China
关键词
BC; Breathomics; Volatile organic compounds; Diagnosis; Progression monitoring; METHIONINE;
D O I
10.1016/j.aca.2024.342883
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: In this study, exhaled breath testing has been considered a promising method for the detection and monitoring of breast cancer (BC). Methods: A high-pressure photon ionization time-of-flight mass spectrometry (HPPI-TOFMS) platform was used to detect volatile organic compounds (VOCs) in breath samples. Then, machine learning (ML) models were constructed on VOCs for the diagnosis of BC and its progression monitoring. Ultimately, 1981 women with useable breath samples were included in the study, of whom 937 (47.3 %) had been diagnosed with BC. VOC panels were used for ML model construction for BC detection and progression monitoring. Results: On the blinded testing cohort, this VOC-based model successfully differentiated patients with and without BC with sensitivity, specificity, and area under receiver operator characteristic curve (AUC) values of 85.9 %, 90.4 %, and 0.946. The corresponding AUC values when differentiating between patients with and without lymph node metastasis (LNM) or between patients with tumor-node-metastasis (TNM) stage 0/I/II or III/ IV disease were 0.840 and 0.708, respectively. While developed VOC-based models exhibited poor performance when attempting to differentiate between patients based on pathological patterns (Ductal carcinoma in situ (DCIS) vs Invasive BC (IBC)) or molecular subtypes (Luminal vs Human epidermal growth factor receptor 2 (HER2+) +) vs Triple-negative BC (TNBC)) of BC. Conclusion: Collectively, the HPPI-TOFMS-based breathomics approaches may offer value for the detection and progression monitoring of BC. Additional research is necessary to explore the fundamental mechanisms of the identified VOCs.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Rapid Identification and Quantification of Linear Olefin Isomers by Online Ozonolysis-Single Photon Ionization Time-of-Flight Mass Spectrometry
    Xie, Yuanyuan
    Chen, Ping
    Hua, Lei
    Hou, Keyong
    Wang, Yongchao
    Wang, Haiyan
    Li, Haiyang
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2016, 27 (01) : 144 - 152
  • [32] TIME-OF-FLIGHT MASS-SPECTROMETRY USING MULTIPHOTON IONIZATION AND IR MULTIPLE PHOTON DISSOCIATION - DECOMPOSITION OF THE TRIETHYLAMINE CATION
    CHOU, JS
    SUMIDA, D
    WITTIG, C
    CHEMICAL PHYSICS LETTERS, 1983, 100 (03) : 209 - 213
  • [33] Measurement of Volatile Organic Compounds in Vehicle Exhaust Using Single-Photon Ionization Time-of-Flight Mass Spectrometry
    Yukio Yamamoto
    Yasuaki Kambe
    Hiroyuki Yamada
    Kenichi Tonokura
    Analytical Sciences, 2012, 28 : 385 - 390
  • [34] Measurement of Volatile Organic Compounds in Vehicle Exhaust Using Single-Photon Ionization Time-of-Flight Mass Spectrometry
    Yamamoto, Yukio
    Kambe, Yasuaki
    Yamada, Hiroyuki
    Tonokura, Kenichi
    ANALYTICAL SCIENCES, 2012, 28 (04) : 385 - 390
  • [35] Measurement of volatile organic compounds in vehicle exhaust using single-photon ionization time-of-flight mass spectrometry
    Department of Environment Systems, Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8563, Japan
    不详
    不详
    Anal. Sci., 4 (385-390):
  • [36] Identification of Nocardia species using matrix-assisted laser desorption/ionization–time-of-flight mass spectrometry
    Shunsuke Segawa
    Motoi Nishimura
    Kazuyuki Sogawa
    Sachio Tsuchida
    Shota Murata
    Masaharu Watanabe
    Kazuyuki Matsushita
    Katsuhiko Kamei
    Fumio Nomura
    Clinical Proteomics, 2015, 12
  • [37] Rapid identification of haloarchaea and methanoarchaea using the matrix assisted laser desorption/ionization time-of-flight mass spectrometry
    Chao-Jen Shih
    Sheng-Chung Chen
    Chieh-Yin Weng
    Mei-Chin Lai
    Yu-Liang Yang
    Scientific Reports, 5
  • [38] Rapid identification of haloarchaea and methanoarchaea using the matrix assisted laser desorption/ionization time-of-flight mass spectrometry
    Shih, Chao-Jen
    Chen, Sheng-Chung
    Weng, Chieh-Yin
    Lai, Mei-Chin
    Yang, Yu-Liang
    SCIENTIFIC REPORTS, 2015, 5
  • [39] The potential of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for the identification of biogroups of Cronobacter sakazakii
    Karamonova, Ludmila
    Junkova, Petra
    Mihalova, Denisa
    Javurkova, Barbora
    Fukal, Ladislav
    Rauch, Pavel
    Blazkova, Martina
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (03) : 409 - 418
  • [40] Characterization of biomass pyrolysis vapors with molecular beam, single photon ionization time-of-flight mass spectrometry
    Brown, AL
    Dayton, DC
    Nimlos, MR
    Daily, JW
    CHEMOSPHERE, 2001, 42 (5-7) : 663 - 669