A novel "ON-OFF-ON" colorimetric and fluorescence dual-signal sensing APAP based on TSPP-Fe3+

被引:1
|
作者
Ma, Tianfeng [1 ,2 ,3 ]
Jia, Yanyan [4 ]
Shi, Lin [1 ,2 ,3 ]
Xu, Xiaohua [1 ,2 ,3 ]
Zheng, Kun [1 ,2 ,3 ]
Fu, Zijia [1 ,2 ,3 ]
Wang, Huan [1 ,2 ,3 ]
Lu, Yongchang [1 ,2 ,3 ]
机构
[1] Phytochem Key Lab Tibetan Plateau Qinghai Prov, Xining, Peoples R China
[2] Modern Tibetan Med Creat Engn Technol Res Ctr Qing, Xining, Peoples R China
[3] Qinghai Minzu Univ, Coll Pharm, Xining, Peoples R China
[4] QingHai Higher Vocat & Tech Inst, Haidong, Peoples R China
关键词
TSPP; Dual; -signal; APAP; ON-OFF-ON; Fe3+; NONSTEROIDAL ANTIINFLAMMATORY DRUGS; PORPHYRIN; ACETAMINOPHEN; PERFORMANCE; PARACETAMOL; SENSOR; STATE;
D O I
10.1016/j.saa.2024.124759
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Acetaminophen, also known as paracetamol (APAP), is a commonly used over-the-counter medication that is often used to treat headaches, toothaches, joint pain, muscle pain, and to lower body temperature. However, overdose can lead to liver damage, gastrointestinal distress, kidney damage, and cardiovascular disease. Therefore, it is very important to establish a method to quickly detect APAP. A novel "ON-OFF-ON" colorimetric and fluorescence dual-signal sensing system was constructed for the quantitative detection of APAP based on 5,10,15,20-tetrakis(4-sulphonatophenyl) porphyrin (TSPP) dual-signal probe. The absorbance and fluorescence intensity of TSPP respectively were quenched when Fe3+ was introduced into TSPP solution. At this point, the color of the corresponding solution changed from red to green. The absorbance and fluorescence intensity of TSPP respectively were restored when APAP was added to the TSPP-Fe3+ system. At this time, the color of the solution changed from green to colorless. Therefore, an "ON-OFF-ON" dual-signal sensing study of APAP were constructed using TSPP as the colorimetric and fluorescent probe. The proposed colorimetric sensing system had a wide linear range in the 13.12 mM - 23.20 mM with 0.11 mM of limit of detection (LOD, S/N = 3). And the proposed fluorescence sensing system had a wide linear range in the 3.45 mM - 12.50 mM and 41.67 mM Spectrochimica Spectroscopy (2024) 65.22 mM with 0.83 mM of limit of detection (LOD, S/N = 3). The dual -signal sensing system were applied to the APAP detection of real samples.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Electrochemical and colorimetric dual-signal detection of Staphylococcus aureus enterotoxin B based on AuPt bimetallic nanoparticles loaded Fe-N-C single atom nanocomposite
    Huan Liang
    Hongcheng Liu
    Haojian Lin
    Guobao Ning
    Xiaokang Lu
    Siying Ma
    Fei Liu
    Hui Zhao
    Canpeng Li
    Food Science and Human Wellness, 2024, 13 (04) : 2025 - 2035
  • [42] Electrochemical and colorimetric dual-signal detection of Staphylococcus aureus enterotoxin B based on AuPt bimetallic nanoparticles loaded Fe-N-C single atom nanocomposite
    Liang, Huan
    Liu, Hongcheng
    Lin, Haojian
    Ning, Guobao
    Lu, Xiaokang
    Ma, Siying
    Liu, Fei
    Zhao, Hui
    Li, Canpeng
    FOOD SCIENCE AND HUMAN WELLNESS, 2024, 13 (04) : 2025 - 2035
  • [43] A Novel Series Colorimetric and Off-On Fluorescent Chemosensors for Fe3+ Based on Rhodamine B Derivative
    Zhang, Di
    Zou, Ruyi
    Wang, Min
    Chai, Meimei
    Wang, Xubin
    Ye, Yong
    Zhao, Yufen
    JOURNAL OF FLUORESCENCE, 2013, 23 (01) : 13 - 19
  • [44] A novel quinoline derivative as dual chemosensor for selective sensing of Al3+ by fluorescent and Fe2+ by colorimetric methods
    Ding, Yongjie
    Zhao, Chunxiang
    Zhang, Pengcheng
    Chen, Yahong
    Song, Weiwu
    Liu, Guanglu
    Liu, Zengchen
    Yun, Lin
    Han, Ruiqi
    JOURNAL OF MOLECULAR STRUCTURE, 2021, 1231
  • [45] A highly efficient and selective coumarin based fluorescent probe for colorimetric detection of Fe3+ and fluorescence dual sensing of Zn2+ and Cu2+
    Roy, Nayan
    Nath, Surjatapa
    Dutta, Abhijit
    Mondal, Paritosh
    Paul, Pradip C.
    Singh, T. Sanjoy
    RSC ADVANCES, 2016, 6 (68): : 63837 - 63847
  • [46] A dual-signal optical sensing platform of CDs-MnO2 NS composites for facile detection of ascorbic acid based on a combination of Tyndall effect scattering and fluorescence
    Zhou, Shujing
    Wan, Jing
    Zou, Jianmei
    Zhang, Yulan
    He, Huijun
    Li, Wei
    Hu, Jiale
    Nie, Jinfang
    Yuan, Yali
    Zhang, Yun
    RSC ADVANCES, 2024, 14 (25) : 17491 - 17497
  • [47] Fluorescence sensing platform based on ruthenium(II) complexes as high 3S (sensitivity, specificity, speed) and "on-off-on" sensors for the miR-185 detection
    Sun, Bin
    Liang, Zhen
    Xie, Bao-Ping
    Li, Rong-Tian
    Li, Lin-Ze
    Jiang, Zhi-Hong
    Bai, Li-Ping
    Chen, Jin-Xiang
    TALANTA, 2018, 179 : 658 - 667
  • [48] On-off-on fluorescence sensing of glutathione in food samples based on a graphitic carbon nitride (g-C3N4)-Cu2+ strategy
    Yang, Chunlei
    Wang, Xiu
    Liu, Haiyun
    Ge, Shenguang
    Yu, Jinghua
    Yan, Mei
    NEW JOURNAL OF CHEMISTRY, 2017, 41 (09) : 3374 - 3379
  • [49] Dual-recognition colorimetric sensing of thrombin based on surface-imprinted aptamer-Fe3O4
    Shen, Mingmei
    Wang, Yuanyuan
    Kan, Xianwen
    JOURNAL OF MATERIALS CHEMISTRY B, 2021, 9 (20) : 4249 - 4256
  • [50] A novel rhodamine-based fluorescent and colorimetric "off-on" chemosensor and investigation of the recognizing behavior towards Fe3+
    She, Mengyao
    Yang, Zheng
    Yin, Bing
    Zhang, Jin
    Gu, Jia
    Yin, Wenting
    Li, Jianli
    Zhao, Guifang
    Shi, Zhen
    DYES AND PIGMENTS, 2012, 92 (03) : 1337 - 1343