Do Stone Characteristics and Laser Fiber Size Affect Ho: YAG Laser Time and Energy During Ureteroscopy?

被引:0
|
作者
Hilowle, Abdihamid Hassan [1 ]
Mohamed, Abdikarim Hussein [2 ]
机构
[1] Mogadishu Urol Ctr, Urol Dept, Mogadishu, Somalia
[2] Univ Somalia, Urol Dept, Mogadishu, Somalia
来源
关键词
stone size; attenuation; stone density; Ho; YAG laser; cumulative laser energy; LITHOTRIPSY EFFICIENCY VARIES; HOLMIUM;
D O I
10.2147/RRU.S464098
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Objective: To assess the correlation of attenuation value measured as HU in Non-contrast computed tomography, stone size, location, fibre size and stone composition with Holmium: yttrium-aluminium garnet (Ho: YAG) laser parameters including, cumulative laser energy and final laser time. Materials and Methods: We prospectively analyzed 118 patients undergoing flexible/semirigid ureteroscopy and Holmium: YAG laser lithotripsy from October 2022 to October 2023 at Mogadishu Urological Centre. Our study parameters encompass preoperative stone characteristics determined in NCCT (stone size, attenuation value, and stone location), fibre size, cumulative laser energy and time, overall operative time, and postoperative stone composition analysis. Results: There were 118 patients eligible for our prospective study. In the logistic regression model for retrograde intrarenal surgery with a fibre size of 272 mu m, cumulative laser energy showed a significant difference among stone size, location, fibre size, and calcium oxalate stones (P > 0.05). However, no significant difference was noticed in the attenuation value (P = 0.078) (R2 = 0.053). Our analysis showed a positive significance among all the parameters (P < 0.05) for laser time. In logistic regression for a rigid ureteroscope with a fibre size of 365 mu m, cumulative laser energy showed a significant difference between the location stone and fibre size (P < 0.05) (R2 = 0.09). However, no significant difference was seen among stone size, attenuation value, and calcium oxalate stones (P > 0.05). For laser time, our analysis showed a positive significance among all parameters except the calcium oxalate stones, which showed no significant difference (P > 0.05). Conclusion: Our study showed that stone location, hardness, and fibre size are the most critical factors influencing the outcome of Ho: YAG laser parameters. The study revealed that CaOMH stones require more time to disintegrate into smaller ones, while PHdependent stones such as carbonate apatite may require less time to fragment.
引用
收藏
页码:115 / 121
页数:7
相关论文
共 50 条
  • [21] Temperature changes during laser lithotripsy with Ho:YAG laser and novel Tm-fiber laser: a comparative in-vitro study
    Taratkin, Mark
    Laukhtina, Ekaterina
    Singla, Nirmish
    Kozlov, Vasily
    Abdusalamov, Abdusalam
    Ali, Stanislav
    Gabdullina, Svetlana
    Alekseeva, Tatyana
    Enikeev, Dmitry
    WORLD JOURNAL OF UROLOGY, 2020, 38 (12) : 3261 - 3266
  • [22] Temperature changes during laser lithotripsy with Ho:YAG laser and novel Tm-fiber laser: a comparative in-vitro study
    Mark Taratkin
    Ekaterina Laukhtina
    Nirmish Singla
    Vasily Kozlov
    Abdusalam Abdusalamov
    Stanislav Ali
    Svetlana Gabdullina
    Tatyana Alekseeva
    Dmitry Enikeev
    World Journal of Urology, 2020, 38 : 3261 - 3266
  • [23] Laser Fiber Displacement Velocity during Tm-Fiber and Ho:YAG Laser Lithotripsy: Introducing the Concept of Optimal Displacement Velocity
    Panthier, Frederic
    Germain, Thibault
    Gorny, Cyril
    Berthe, Laurent
    Doizi, Steeve
    Traxer, Olivier
    JOURNAL OF CLINICAL MEDICINE, 2022, 11 (01)
  • [24] How to perform the dusting technique for calcium oxalate stone phantoms during Ho:YAG laser lithotripsy
    Jeong Woo Lee
    Min Gu Park
    Sung Yong Cho
    BMC Urology, 18
  • [25] How to perform the dusting technique for calcium oxalate stone phantoms during Ho:YAG laser lithotripsy
    Lee, Jeong Woo
    Park, Min Gu
    Cho, Sung Yong
    BMC UROLOGY, 2018, 18
  • [26] Impact of laser fiber tip cleavage on power output for ureteroscopy and stone treatment
    Haddad, M.
    Emiliani, E.
    Rouchausse, Y.
    Coste, F.
    Berthe, L.
    Doizi, S.
    Buttice, S.
    Somani, B.
    Traxer, O.
    WORLD JOURNAL OF UROLOGY, 2017, 35 (11) : 1765 - 1770
  • [27] IMPACT OF LASER FIBER TIP CLEAVAGE ON POWER OUTPUT FOR URETEROSCOPY AND STONE TREATMENT
    Haddad, Mattieu
    Emiliani, Esteban
    Doizi, Steeve
    Rouchausse, Yann
    Coste, Frederic
    Berthe, Laurent
    Traxer, Olivier
    JOURNAL OF UROLOGY, 2017, 197 (04): : E684 - E685
  • [28] Accordion stone management device function is unaffected by Ho:Yag laser contact
    Vejdani, Kaveh
    Berger, Aaron
    Stoller, Marshall
    JOURNAL OF ENDOUROLOGY, 2007, 21 : A15 - A15
  • [29] Impact of laser fiber tip cleavage on power output for ureteroscopy and stone treatment
    M. Haddad
    E. Emiliani
    Y. Rouchausse
    F. Coste
    L. Berthe
    S. Doizi
    S. Buttice
    B. Somani
    O. Traxer
    World Journal of Urology, 2017, 35 : 1765 - 1770
  • [30] Tm:fiber laser in-band pumping a cryogenically-cooled Ho:YAG laser
    Mackenzie, J. I.
    Bailey, W. O. S.
    Kim, J. W.
    Pearson, L.
    Shen, D. Y.
    Yang, Y.
    Clarkson, W. A.
    SOLID STATE LASERS XVIII: TECHNOLOGY AND DEVICES, 2009, 7193