SHORT-TERM OPTIMIZATION OF A COMBINED CYCLE POWER PLANT INTEGRATED WITH AN INLET AIR CONDITIONING UNIT

被引:0
|
作者
Mantilla, Weimar [1 ]
Garcia, Jose [1 ]
Guedez, Rafael [1 ]
Sorce, Alessandro [2 ]
机构
[1] KTH Royal Inst Technol, Heat & Power Technol, S-10044 Stockholm, Sweden
[2] Univ Genoa, Mech Engn, I-16145 Genoa, Italy
关键词
FLEXIBILITY;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Under new scenarios with high shares of variable renewable electricity, combined cycle gas turbines (CCGT) are required to improve their flexibility, in terms of ramping capabilities and part-load efficiency, to help balance the power system. Simultaneously, liberalization of electricity markets and the complexity of its hourly price dynamics are affecting the CCGT profitability, leading the need for optimizing its operation. Among the different possibilities to enhance the power plant performance, an inlet air conditioning unit (ICU) offers the benefit of power augmentation and "minimum environmental load" (MEL) reduction by controlling the gas turbine inlet temperature using cold thermal energy storage and a heat pump. Consequently, an evaluation of a CCGT integrated with this inlet conditioning unit including a day-ahead optimized operation strategy was developed in this study. To establish the hourly dispatch of the power plant and the operation mode of the inlet conditioning unit to either cool down or heat up the gas turbine inlet air, a mixed-integer linear optimization (MILP) was formulated using MATLAB, aiming to maximize the operational profit of the plant within a 24-hours horizon. To assess the impact of the proposed unit operating under this dispatch strategy, historical data of electricity and natural gas prices, as well as meteorological data and CO2 emission allowances price, have been used to perform annual simulations of a reference power plant located in Turin, Italy. Furthermore, different equipment capacities and parameters have been investigated to identify trends of the power plant performance. Lastly, a sensitivity analysis on market conditions to test the control strategy response was also considered. Results indicate that the inlet conditioning unit, together with the dispatch optimization, increases the power plant's operational profit by achieving a wider operational range, particularly important during peak and off-peak periods. For the specific case study, it is estimated that the net present value of the CCGT integrated with the ICU is 0.5% higher than the power plant without the unit. In terms of technical performance, results show that the unit reduces the minimum environmental load by approximately 1.34% and can increase the net power output by 0.17% annually.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Short-term wind power prediction based on combined long short-term memory
    Zhao, Yuyang
    Li, Lincong
    Guo, Yingjun
    Shi, Boming
    Sun, Hexu
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2024, 18 (05) : 931 - 940
  • [22] Process and Carbon Footprint Analyses of the Allam Cycle Power Plant Integrated with an Air Separation Unit
    Fernandes, Dan
    Wang, Song
    Xu, Qiang
    Buss, Russel
    Chen, Daniel
    CLEAN TECHNOLOGIES, 2019, 1 (01): : 325 - 340
  • [23] Combined cycle power plant with integrated solar system
    Rheinländer, J
    Horn, M
    Führing, H
    BRENNSTOFF-WARME-KRAFT, 2001, 53 (06): : 55 - +
  • [24] Energy efficiency and exergetic analysis of combined cycle plant with inlet air cooling
    Padhi B.N.
    Pattanayak L.
    International Journal of Ambient Energy, 2023, 44 (01) : 2433 - 2445
  • [25] POWER AUGMENTATION STUDY OF AN EXISTING COMBINED CYCLE POWER PLANT BY OVERSPRAY INLET FOGGING
    Chiang, Hsiao-Wei D.
    Wang, Pai-Yi
    Li, Hsin-Lung
    PROCEEDINGS OF THE ASME TURBO EXPO 2008, VOL 2, 2008, : 863 - 870
  • [26] Optimization of Auxiliary Power Consumption of Combined Cycle Power Plant
    Raval, Tejas N.
    Patel, R. N.
    CHEMICAL, CIVIL AND MECHANICAL ENGINEERING TRACKS OF 3RD NIRMA UNIVERSITY INTERNATIONAL CONFERENCE ON ENGINEERING (NUICONE2012), 2013, 51 : 751 - 757
  • [27] Ant lion optimization for short-term wind integrated hydrothermal power generation scheduling
    Dubey, Hari Mohan
    Pandit, Manjaree
    Panigrahi, B. K.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 83 : 158 - 174
  • [28] Natural Gas Combined Cycle Power Plant Integrated to Capture Plant
    Karimi, Mehdi
    Hillestad, Magne
    Svendsen, Hallvard F.
    ENERGY & FUELS, 2012, 26 (03) : 1805 - 1813
  • [29] Design of a combined cycle power plant model for optimization
    Tica, Adrian
    Gueguen, Herve
    Dumur, Didier
    Faille, Damien
    Davelaar, Frans
    APPLIED ENERGY, 2012, 98 : 256 - 265
  • [30] Performance optimization for an open-cycle gas turbine power plant with a refrigeration cycle for compressor inlet air cooling. Part 2: power and efficiency optimization
    Zhang, W.
    Chen, L.
    Sun, F.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2009, 223 (A5) : 515 - 522