Assessment of the effect of hemoglobinopathies on the measurement of HbA1c: Comparison of two HPLC separation kits on D10 BIO-RAD (HbA1c kit and dual kit)

被引:0
|
作者
Deghima, S. [1 ,2 ]
Nachi, K. [1 ]
Outayeb, A. [1 ]
Djenouhat, K. [1 ,2 ]
机构
[1] Univ Algiers 1, Fac Med, Algiers, Algeria
[2] Rouiba Hosp, Cent Lab Med Biol, Algiers, Algeria
关键词
D O I
10.1016/j.cca.2024.118066
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
P1287
引用
收藏
页数:2
相关论文
共 50 条
  • [31] Interference of Hemoglobin (Hb) Hope on Measurement of HbA1c Using an HPLC Method
    Lorenzo-Medina, Mercedes
    De-La-Iglesia, Silvia
    Ropero, Paloma
    Nogueira-Salgueiro, Patricia
    Gonzalez-Fernandez, F. Ataulfo
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2021, 15 (04): : 974 - 975
  • [32] Influence of RBC Indices on HbA1c Measurement by Capillary Electrophoresis and HPLC Methods
    Juang, Yi-Jie
    Wu, Hsin-Mian
    Cheng, Ya-Wen
    Eng, Hock-Liew
    Lin, Tsun-Mei
    CLINICAL LABORATORY, 2022, 68 (08) : 1657 - 1665
  • [33] Comparison of two hemolysis procedures prior to an automated HbA1c immunoassay
    Schneider, N
    Ruiz, P
    Gillery, P
    CLINICA CHIMICA ACTA, 2002, 325 (1-2) : 47 - 50
  • [34] Haemoglobin A1c: evaluation of a new HbA1c point-of-care analyser Bio-Rad in2it in comparison with the DCA 2000 and central laboratory analysers
    Yeo, Chin-Pin
    Tan, Carol Hui-Chen
    Jacob, Edward
    ANNALS OF CLINICAL BIOCHEMISTRY, 2009, 46 : 373 - 376
  • [35] Determination of HbA1c in the presence of haemoglobin variants:: Comparison of three HPLC techniques
    Carta, M
    Dall'Olio, G
    Soffiati, G
    EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1997, 35 (12): : 923 - 925
  • [36] Effect of hemoglobin N Baltimore on HbA1c measurement in six methods
    Ratnam, Caroline
    Houangkeo, Thu Hai Yen Tran
    Moutereau, Stephane
    Plantamura, Julie
    Sollier, Mathilde
    Garcia, Cyril
    Delacour, Herve
    ANNALES DE BIOLOGIE CLINIQUE, 2019, 77 (02) : 155 - 159
  • [37] Effect of HbE trait on measurement of HbA1c by three different methods
    Azizi, Arjoanna
    Sthaneshwar, Pavai
    Shanmugam, Hemalatha
    Arumugam, Shanmuganathan
    PATHOLOGY, 2015, 47 (05) : 495 - 497
  • [38] Determination of HbA1c in the presence of unusual hemoglobin variants:: A comparison of results from the Bayer DCA-2000 and the Bio-Rad Variant II.
    Lloyd, Kelly A.
    Doersch, Marcia
    Mamiya, Linda Y.
    Sabath, Daniel E.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2006, 126 (03) : 473 - 473
  • [39] A simple means to differentiate labile HbA1c from haemoglobin variant on Bio-Rad Variant II Turbo 2.0 cation-exchange HPLC method
    Cheng, Wan Ling
    Neo, Siew Fong
    Chew, Suru
    Sethi, Sunil Kumar
    Loh, Tze Ping
    PATHOLOGY, 2017, 49 (07) : 817 - 818
  • [40] Comparison of analytical interferences on HbA1c measurement by two high pressure liquid chromatography analyzers
    Jaisson, Stephane
    Guillard, Emmanuelle
    Leroy, Nathalie
    Gillery, Philippe
    ANNALES DE BIOLOGIE CLINIQUE, 2011, 69 (01) : 63 - 69