Assessment of the effect of hemoglobinopathies on the measurement of HbA1c: Comparison of two HPLC separation kits on D10 BIO-RAD (HbA1c kit and dual kit)

被引:0
|
作者
Deghima, S. [1 ,2 ]
Nachi, K. [1 ]
Outayeb, A. [1 ]
Djenouhat, K. [1 ,2 ]
机构
[1] Univ Algiers 1, Fac Med, Algiers, Algeria
[2] Rouiba Hosp, Cent Lab Med Biol, Algiers, Algeria
关键词
D O I
10.1016/j.cca.2024.118066
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
P1287
引用
收藏
页数:2
相关论文
共 50 条
  • [1] Evaluation of an Improved Bio-Rad VARIANT™ II TURBO HbA1c Kit
    Tapply, C. B.
    Yu, F. H.
    Lee, H. K.
    CLINICAL CHEMISTRY, 2009, 55 (06) : A175 - A175
  • [2] Evaluation of the new kit HbA1c Analyzer 2.0 Variant II Turbo (Bio-Rad)
    Meurice, Julie
    Guillard, Emmanuelle
    Jaisson, Stephane
    Leroy, Nathalie
    Gillery, Philippe
    ANNALES DE BIOLOGIE CLINIQUE, 2011, 69 (05) : 561 - 569
  • [3] Can EDTA, EDTA-fluoride, and buffered citrate tubes be used for measurement of HbA1c on the Bio-Rad D10?
    Chakraborty, Sutirtha
    Ghosh, Sidhartha Sankar
    Das, Anupam
    Sawant, Prasad
    Kallner, Anders
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2015, 53 (01) : E5 - E8
  • [4] Silent haemoglobin variants and determination of HbA1c with the HPLC Bio-Rad Variant II
    Lahousen, T
    Roller, RE
    Lipp, RW
    Schnedl, WJ
    JOURNAL OF CLINICAL PATHOLOGY, 2002, 55 (09) : 699 - 703
  • [5] Evaluation of HBA1C measurement on Architect CI8200 (Abbott Diagnostic). Comparison with HPLC D-10 Bio-Rad assay
    Beaune, G.
    Ducruet, J.
    Jund, J.
    Favre, S.
    ANNALES DE BIOLOGIE CLINIQUE, 2009, 67 (01) : 101 - 107
  • [6] Analytical evaluation of the Bio-Rad Variant II automated HbA1c analyzer
    Higgins, TN
    Blakney, GB
    Dayton, J
    CLINICAL BIOCHEMISTRY, 2001, 34 (05) : 361 - 365
  • [7] Evaluation of the Bio-Rad VARIANT™ II HbA2/HbA1C Dual Program for measurement of hemoglobin concentrations and detection of variants
    Riou, J
    Godart, C
    Mathis, M
    Hurtrel, D
    Wajcman, H
    Préhu, C
    Bardakdjian, J
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2005, 43 (02) : 237 - 243
  • [8] Evaluation of Variant II® analyzer equipped with the new 270-2101 NU kit (Bio-Rad) for HbA1c assay
    Lavalard, E.
    Szymezak, J.
    Leroy, N.
    Gillery, P.
    ANNALES DE BIOLOGIE CLINIQUE, 2009, 67 (01) : 55 - 65
  • [9] INTERFERENCE ON HbA1C MEASUREMENT BY HPLC: HB D
    Kalayci, Mehmet
    Ayyildiz, Hakan
    Bozkurt, Mahmut
    Timurkaan, Mustafa
    NOBEL MEDICUS, 2016, 12 (02): : 66 - 68
  • [10] Evaluation of Bio-Rad D100 for HbA1c testing of dried blood spot samples
    Wei, Ruhan
    Kroner, Grace
    Reineks, Edmunds
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2022, 158 (SUPP 1) : S11 - S11