Post-fire seismic performance of steel-reinforced concrete frames: Experiment

被引:0
|
作者
Wang, Guang-yong [1 ]
Cui, Xing-chen [1 ]
Li, Zheng [1 ]
Liu, Ren-jie [1 ]
机构
[1] Yantai Univ, Sch Civil Engn, Yantai 264005, Peoples R China
基金
中国国家自然科学基金;
关键词
Fire; Seismic performance; Hysteretic curve; Stiffness; Load bearing capacity; BEHAVIOR; COLUMNS; BEAM;
D O I
10.1016/j.istruc.2024.106921
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Considering the combined effect of fire and loading, experimental studies were conducted to investigate the mechanical properties during the heating and cooling phases as well as the post-fire seismic performance of steel reinforced concrete (SRC) column-reinforced concrete (RC) beam planar frame structures. The experiments focused on studying the temperature and deformation changes of the frame structure during the heating and cooling process, as well as the post-fire bearing capacity, hysteresis curve, stiffness, ductility, and damping coefficient. The research results showed that the deformation of the frame increased compared with the pre-fire condition, indicating that the stiffness of the frame decreased after heating and cooling. The residual deformation in the out-of-plane direction caused the failure of the frame during the post-fire seismic test, and the residual deformation and concrete spalling reduced the post-fire seismic load bearing capacity of the SRC column-RC beam-frame structures. Under horizontal cyclic loading after fire, the concrete at the bottom end of the column was gradually crushed, leading to the formation of plastic hinge, while noticeable shear and bending deformations occurred at the beam end near the beam-column joint region, eventually resulting in structural failure. The frame specimens after fire exhibited a lozenge-shaped hysteretic loop under horizontal load - horizontal displacement, characterized by the fullness of the hysteretic loop and the strong energy dissipation capability. Compared with the unheated specimen, the load bearing capacity of the fire-exposed frame specimens was reduced by thirty percent, and the stiffness at a horizontal displacement of 2 mm was reduced by thirty eight percent.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Shaking table test on seismic performance of towering steel-reinforced concrete tube structure
    Ou T.
    Liu Y.
    Tan P.
    Liu X.
    Zhou F.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (04): : 36 - 46
  • [42] Performance of Steel-Reinforced Concrete Column after Exposure to Fire: FEA Model and Experiments
    Han, Lin-Hai
    Zhou, Kan
    Tan, Qing-Hua
    Song, Tian-Yi
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (09)
  • [43] Fire and post-fire performance of blind-bolted concrete-filled steel tubular joints with restrained steel beams: Experiment and simulation
    Song, Tian-Yi
    Zhu, Di
    Zhou, Hongyuan
    Xiang, Kai
    Chen, Zheng
    THIN-WALLED STRUCTURES, 2023, 193
  • [44] Experimental study on seismic performance of steel-reinforced recycled concrete frame with infill wall
    Liu, Zuqiang
    Xue, Jianyang
    Qi, Liangjie
    Gao, Liang
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2020, 29 (10):
  • [45] Seismic performance of steel-reinforced recycled concrete columns under low cyclic loads
    Ma, Hui
    Xue, Jianyang
    Zhang, Xicheng
    Luo, Daming
    CONSTRUCTION AND BUILDING MATERIALS, 2013, 48 : 229 - 237
  • [46] Fire and post-fire performance of unbonded semi-precast prestressed reinforced concrete beams
    Zhang, Yongwang
    Zhang, Xiaofei
    Zhang, Ruiyang
    Ni, Weibin
    Zhi, Wentao
    Wang, Lu
    ENGINEERING STRUCTURES, 2024, 308
  • [47] Post-fire behaviour of reinforced concrete stub columns confined by circular steel tubes
    Liu, Faqi
    Gardner, Leroy
    Yang, Hua
    Journal of Constructional Steel Research, 2014, 102 : 82 - 103
  • [48] Post-fire behaviour of reinforced concrete stub columns confined by circular steel tubes
    Liu, Faqi
    Gardner, Leroy
    Yang, Hua
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 102 : 82 - 103
  • [49] Experimental study on post-fire performance of partially precast steel reinforced concrete columns subjected to eccentric compression
    Yang Y.
    Wei B.
    Xue Y.-C.
    Yu Y.-L.
    Gong Z.-C.
    Gongcheng Lixue/Engineering Mechanics, 2020, 37 (03): : 108 - 119
  • [50] Post-fire bond behaviour in elliptical concrete filled steel tubes: Experiment and simulation
    Song, Tian-Yi
    Wang, Cheng-Hao
    Liu, Xia-Lu
    Xiang, Kai
    Zhou, Hongyuan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 201